125 resultados para posterior predictive check
Resumo:
Purpose: To describe sequential phacoemulsification-intraocular lens (IOL) implantation-posterior capsulorhexis-anterior vitrectomy in the management of phakic malignant glaucoma. Methods: Twenty consecutive patients (25 eyes) with phakic malignant glaucoma were enrolled at the Zhongshan Ophthalmic Center, Sun Yat-sen University. All patients underwent phacoemulsification, IOL implantation and posterior capsulorhexis together with anterior vitrectomy via a clear corneal paracentesis. Visual acuity, intraocular pressure (IOP), anterior chamber depth (ACD), surgical complications and medications required after the surgery were recorded. Results: After surgery, the mean LogMAR visual acuity and ACD increased significantly (visual acuity from -1.56 ± 1.17 to -0.54 ± 0.81, p < 0.001; ACD from 0.367 ± 0.397 mm to 2.390 ± 0.575 mm, p < 0.001), and mean IOP decreased significantly (from 39.6 ± 10.6 mm Hg to 14.5 ± 4.1 mmHg, p < 0.001). No serious perioperative complications occurred, and only five eyes required topical glaucoma medications after surgery. Conclusion: Combined phacoemulsification-IOL implantation-posterior capsulorhexis-anterior vitrectomy surgery is a safe and effective method for treating patients with phakic malignant glaucoma. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Resumo:
PURPOSE:
To quantify the risk for age-related cortical cataract and posterior subcapsular cataract (PSC) associated with having an affected sibling after adjusting for known environmental and personal risk factors.
DESIGN:
Sibling cohort study.
PARTICIPANTS:
Participants in the ongoing Salisbury Eye Evaluation (SEE) study (n = 321; mean age, 78.1+/-4.2 years) and their locally resident siblings (n = 453; mean age, 72.6+/-7.4 years) were recruited at the time of Rounds 3 and 4 of the SEE study. INTERVENTION/TESTING METHODS: Retroillumination photographs of the lens were graded for the presence of cortical cataract and PSC with the Wilmer grading system. The residual correlation between siblings' cataract grades was estimated after adjustment for a number of factors (age; gender; race; lifetime exposure to ultraviolet-B light; cigarette, alcohol, estrogen, and steroid use; serum antioxidants; history of diabetes; blood pressure; and body mass index) suspected to be associated with the presence of cataract.
RESULTS:
The average sibship size was 2.7 per family. Multivariate analysis revealed the magnitude of heritability (h(2)) for cortical cataract to be 24% (95% CI, 6%-42%), whereas that for PSC was not statistically significant (h(2) 4%; 95% CI, 0%-11%) after adjustment for the covariates. The model revealed that increasing age, female gender, a history of diabetes, and black race increased the odds of cortical cataract, whereas higher levels of provitamin A were protective. A history of diabetes and steroid use increased the odds for PSC.
CONCLUSIONS:
This study is consistent with a significant genetic effect for age-related cortical cataract but not PSC.
Resumo:
AIM: To study the effect of posterior capsular opacification (PCO) on vision and visual function in patients undergoing cataract surgery in rural China, and to compare this with the effect of refractive error. METHODS: Patients undergoing cataract surgery in at least one eye by local surgeons in a rural setting between 8 August and 31 December 2005 were examined with slit lamp grading of PCO 10-14 months after surgery. Subjects with any PCO associated with best-corrected visual acuity of 6/7.5 or worse, or with grade 2+ or worse PCO without visual decrement, were offered YAG laser capsulotomy. Vision and self-reported visual function were assessed, and various demographic and clinical factors potentially associated with PCO were recorded. RESULTS: Of 313 patients operated on within the study window, 239 (76%) could be contacted by telephone; study examinations were performed on 176 (74%). Examined subjects had a mean (SD) age of 69.4 (10.5) years, 116 (67%) were female, and 149 (86%) had been blind (presenting visual acuity < or = 6/60) in the operated eye before surgery. PCO of grade 1 or above was present in 34 of 204 operated eyes (16.7%). Those with PCO had significantly worse presenting vision (p = 0.007) but not visual function (p>0.3) than those without PCO. Women had a significantly higher prevalence of PCO (20.9%) than did men (8.6%, p<0.05). Of 19 eyes undergoing capsulotomy with best-corrected visual acuity measured the next day, 13 (68%) improved by one or more lines, and seven (37%) improved by two or more lines. Despite a higher uptake of capsulotomy (95%) as opposed to refraction (35%) in this cohort, the yield in terms of eyes with poor presenting visual acuity (< 6/18) that could be improved was higher for refraction (26% = 9/35) than for capsulotomy (9% = 3/35). CONCLUSION: The prevalence of PCO and impact on vision and visual function in this cohort was modest 1 year after surgery. However, PCO prevalence increases with time. Follow-up of this cohort is underway to determine the effectiveness of this early intervention in identifying and treating subjects who will eventually experience clinically significant PCO.
Resumo:
Dynamical effects of non-conservative forces in long, defect free atomic wires are investigated. Current flow through these wires is simulated and we find that during the initial transient, the kinetic energies of the ions are contained in a small number of phonon modes, closely clustered in frequency. These phonon modes correspond to the waterwheel modes determined from preliminary static calculations. The static calculations allow one to predict the appearance of non-conservative effects in advance of the more expensive real-time simulations. The ion kinetic energy redistributes across the band as non-conservative forces reach a steady state with electronic factional forces. The typical ion kinetic energy is found to decrease with system length, increase with atomic mass, and its dependence on bias, mass and length is supported with a pen and paper model. This paper highlights the importance of non-conservative forces in current carrying devices and provides criteria for the design of stable atomic wires.