186 resultados para hip surgery
Resumo:
The traditional training of surgeons focused exclusively on developing knowledge, clinical expertise, and technical (surgical) skills. However, analyses of the reasons for adverse events in surgery have revealed that many underlying causes originate from behavioural or non-technical aspects of performance (eg, poor communication among members of the surgical team) rather than from a lack of surgical (ie, technical) skills. Therefore, technical skills appear to be necessary but not sufficient to ensure patient safety. Paying attention to non-technical skills, such as team working, leadership, situation awareness, decision making, and communication, will increase the likelihood of maintaining high levels of error-free performance. Identification and training of non-technical skills has been developed for high-risk careers, such as civil aviation and nuclear power. Only recently, training in non-technical skills has been adopted by the surgical world and anaesthetists. Non-technical skills need to be tailored to the environment where they are used, and eye surgery has some substantial differences compared with other surgical areas, for example, high volume of surgery, use of local anaesthetics, and very sophisticated equipment. This review highlights the need for identification of the non-technical skills relevant to eye surgeons and promotion of their use in the training of eye surgeons.
Resumo:
Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).
Resumo:
Objective: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). Design: Nonconsecutive observational case series. Participants and Intervention: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. Main Outcome Measures: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. Results: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5 ± 12 mmHg, and after surgery 11.8 ± 5.2 mmHg (mean follow-up, 26 ± 7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P <0.005). The age of the patient correlated highly with change in maximum cup depth (P <0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). Conclusion: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.
Resumo:
PurposeThe World Health Organisation (WHO) identified patient safety in surgery as an important public health matter and advised the adoption of a universal peri-operative surgical checklist. An adapted version of the WHO checklist has been mandatory in the National Health Service since 2010. Wrong intraocular lens (IOL) implantation is a particular safety concern in ophthalmology. The Royal College of Ophthalmologists launched a bespoke checklist for cataract surgery in 2010 to reduce the likelihood of preventable errors. We sought to ascertain the use of checklists in cataract surgery in 2012.Patients and methodsA survey of members of the Royal College of Ophthalmologists seeking views on the use of checklists in cataract surgery. Four hundred and sixty-nine completed responses were received (18% response rate).ResultsRespondents worked in England (75%), Scotland (11%), Wales (5%), Northern Ireland (2%), the Republic of Ireland (1%), and overseas (6%). Ninety-four per cent of respondents support the use of a checklist for cataract surgery and 85% say that they always use a checklist before cataract surgery. Sixty-seven per cent of cataract surgeons stated they undertake a pre-operative team brief. Thirty-six per cent use a cataract surgery checklist developed locally, 18% use the college's bespoke cataract surgery checklist, 39% use a generic surgical checklist, and 4% reported that they do not use a checklist.ConclusionNinety-three per cent of cataract surgeons responding to the questionnaire report using a surgical checklist and 67% use a team brief. However, only 54% use a checklist, which addresses the selection of the correct intraocular implant. We recommend wider adoption of checklists, which address risks relevant to cataract surgery, in particular the possibility of selection of an incorrect IOL.Eye advance online publication, 24 May 2013; doi:10.1038/eye.2013.101.
Resumo:
Purpose: To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. ?Methods: The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. ?Results: A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (?2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). ?Conclusion: Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.
Resumo:
We report a series of 706 patients (759 hip implants) with an average follow up of 10.5 years (range, 10-11 years) following total hip replacement (THR) using a cemented custom-made femoral stem and a cemented HDP acetabular component. The fate of every implant is known. One hundred and seventy-four patients (23%) were deceased at the time of their 10-year review all died with a functioning THR in situ. Four hundred and sixty-two patients (61%) were subsequently reviewed. One hundred and twenty three patients (16%) were assessed by telephone review, as they were too ill or unwilling to attend. Kaplan-Meier survival analysis (all components) demonstrated a median survival at 10 years of 96.05% or 95% Confidence Intervals (CI) for median survival of (94.41% to 97.22%). Revision surgery occurred in 30 cases (3.9%). Seventeen had full revisions (2.2%) and 13 (1.7%) socket revisions only. Twenty-one out of 30 revisions were for infection or dislocation. There were 2 cases (0.3%) of revision for aseptic loosening of the stem. The 10-year results of the custom femoral titanium stem are encouraging and compare well with other cemented systems.
Resumo:
Restoration of joint centre during total hip arthroplasty is critical. While computer-aided navigation can improve accuracy during total hip arthroplasty, its expense makes it inaccessible to the majority of surgeons. This article evaluates the use, in the laboratory, of a calliper with a simple computer application to measure changes in femoral head centres during total hip arthroplasty. The computer application was designed using Microsoft Excel and used calliper measurements taken pre- and post-femoral head resection to predict the change in head centre in terms of offset and vertical height between the femoral head and newly inserted prosthesis. Its accuracy was assessed using a coordinate measuring machine to compare changes in preoperative and post-operative head centre when simulating stem insertion on 10 sawbone femurs. A femoral stem with a modular neck was used, which meant nine possible head centre configurations were available for each femur, giving 90 results. The results show that using this technique during a simulated total hip arthroplasty, it was possible to restore femoral head centre to within 6?mm for offset (mean 1.67?±?1.16?mm) and vertical height (mean 2.14?±?1.51?mm). It is intended that this low-cost technique be extended to inform the surgeon of a best-fit solution in terms of neck length and neck type for a specific prosthesis.
Resumo:
The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.
Resumo:
Abstract:
Background: An estimated 30-60% of older
adults fall every year and about 1% of falls result in a hip fracture. Hip fracture is a serious and growing problem, with a 3-10 fold rise in worldwide incidence predicted by 2050 (Gullberg, et al 1997). Hip protectors are underwear with built in protection for the greater trochanter. They are designed to prevent hip fractures by dispersing or absorbing the force of a fall. Trials
published to 2001 were broadly supportive of
the effectiveness of hip protectors, and this
was reflected in a Cochrane review in 2000.
However, earlier trials were methodologically
flawed and subsequent trials have not demonstrated effectiveness. The most recent Cochrane review describes only a marginal benefit (Parker et al, 2005).
Review and Discussion: This presentation
evaluates the current evidence for the use
of hip protectors and discusses the use of
that evidence by manufacturers, suppliers,
professional groups and guideline developers.
Interestingly, despite the limitations of the
evidence base, most advice has been broadly
supportive. Reasons for this are proposed
and discussed in the context of a critique of
evidence-based healthcare. protectors. However, the available evidence can be used in different ways and for different purposes by those with an interest in promoting
the use of hip protectors. A conservative
approach is warranted, where, if we cannot
demonstrate that hip protectors work, we
presume that they do not. This presentation will be of use to practitioners wanting to evaluate the evidence base for hip protectors (and other recommended interventions) on behalf of clients. It will also be of interest to policy makers who must assess the claims made for health care technologies as part of the decisionmaking process.
Recommended reading:
Gullberg B, Johnell O, Kanis JA (1997) Worldwide
projections for hip fracture. Osteoporos
Int. 7(5):407-13 .
Parker MJ, Gillespie WJ, Gillespie LD (2005) Hip
protectors for preventing hip fractures in older
people. The Cochrane Database of Systematic
Reviews Issue 3. Art. No.: CD001255.pub3. DOI:
10.1002/14651858.CD001255.pub3.
Resumo:
The paired adrenal (suprarenal) glands are flattened retroperitoneal endocrine glands closely applied to the medial aspect of the superior pole of each kidney. The internal structure of these pale yellow glands are incongruous in that the adrenal gland is composed of two discrete parts, namely an outer cortex enveloping a central medulla. The adrenal cortex and medulla contain distinct endocrine tissues that secrete different hormones and are regulated by separate control systems.