166 resultados para compression set


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Northern Irish (and all UK-based) health care is facing major challenges. This article uses a specific theory to recommend and construct a framework to address challenges faced by the author, such as deficits in compression bandaging techniques in healing venous leg ulcers and resistance found when using evidence-based research within this practice. The article investigates the challenges faced by a newly formed community nursing team. It explores how specialist knowledge and skills are employed in tissue viability and how they enhance the management of venous leg ulceration by the community nursing team. To address these challenges and following a process of reflection, Lewin's forcefield analysis model of change management can be used as a framework for some recommendations made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous poly(L-lactic acid) (PLA) scaffolds of 85 per cent and 90 per cent porosity are prepared using polymer sintering and porogen leaching method. Different weight fractions of 10 per cent, 30 per cent, and 50 per cent of hydroxyapatite (HA) are added to the PLA to control the acidity and degradation rate. The three-dimensional (3D) morphology and surface porosity are tested using micro-computer tomography (micro-CT), optical microscopy, and scanning electron microscopy (SEM). Results indicate that the surface porosity does not change on the addition of HA. The micro-CT examinations show a slight decrease in the pore size and increase in the wall thickness accompanied by reduced anisotropy for the scaffolds containing HA. Scanning electron micrographs show detectable interconnected pores for the scaffold with pure PLA. Addition of the HA results in agglomeration of the HA particles and reduced leaching of the porogen. Compression tests of the scaffold identify three stages in the stress-strain curve. The addition of HA results in a reduction in the modulus of the scaffold at the first stage of elastic bending of the wall, but this is reversed for the second and third stages of collapse of the wall and densification in the compression tests. In the scaffolds with 85 per cent porosity, the addition of a high percentage of HA could result in 70 per cent decrease in stiffness in the first stage, 200 per cent increase in stiffness in the second stage, and 20 per cent increase in stiffness in the third stage. The results of these tests are compared with the Gibson cellular material model that is proposed for prediction of the behaviour of cellular material under compression. The pH and molecular weight changes are tracked for the scaffolds within a period of 35 days. The addition of HA keeps the pH in the alkaline region, which results in higher rate of degradation at an early period of observation, followed by a reduced rate of degradation later in the process. The final molecular weight is higher for the scaffolds with HA than for scaffolds of pure PLA. The manufactured scaffolds offer acceptable properties in terms of the pore size range and interconnectivity of the pores and porosity for non-load-bearing bone graft substitute; however, improvement to the mixing of the phases of PLA and HA is required to achieve better integrity of the composite scaffolds. © 2008 IMechE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this research, we have investigated the effects of addition of different percentages of nanoclay to the ethylene propylene diene monomer (EPDM) and nitrile butadiene rubber (NBR) on the characteristics of these rubbers as seal material. Properties such as tensile strength, modulus at different extensions, elongation at break, compressive set, hardness, and permeability and abrasion resistance are tested to assess the effect of addition of the nanoclay. Results indicate that addition of nanoclay at certain compositions could slightly reduce the strength of the rubber. However more stable modulus at different strains are provided, the hardness of the rubber is preserved and slightly enhanced, the permeability is reduced in both rubbers especially considerable decrease in EPDM is observed which is desirable in diminishing the effect of explosive decompression. At the same time the compression test shows that the nanoclay improves the performance of the rubbers under compression which is essential in seal application. The X-ray diffraction tests clarify that the dispersion of the nanoclay in the NBR samples is of high quality. In the EPDM samples, the dispersion is in need of improvement. POLYM. COMPOS., 30:1657-1667, 2009. © 2008 Society of Plastics Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of cylindrical porous titanium test samples were produced using the three-dimensional printing and sintering method with samples sintered at 900 °C, 1000 °C, 1100 °C, 1200 °C or 1300 °C. Following compression testing, it was apparent that the stress-strain curves were similar in shape to the curves that represent cellular solids. This is despite a relative density twice as high as what is considered the threshold for defining a cellular solid. As final sintering temperature increased, the compressive behaviour developed from being elastic-brittle to elastic-plastic and while Young's modulus remained fairly constant in the region of 1.5 GPa, there was a corresponding increase in 0.2% proof stress of approximately 40-80 MPa. The cellular solid model consists of two equations that predict Young's modulus and yield or proof stress. By fitting to experimental data and consideration of porous morphology, appropriate changes to the geometry constants allow modification of the current models to predict with better accuracy the behaviour of porous materials with higher relative densities (lower porosity).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an investigation of the effect of fill factor; on the compaction behaviour of the granules during tableting and hence mechanical properties of tablets formed. The fill factor; which is the ratio of volume of wet powder material to vessel volume of the granulator, was used as an indicator of batch size. It has been established previously that in high shear granulation the batch size influences the size distribution and granule mechanical properties [1]. The work reported in this paper is an extension to the work presented in [1], hence granules from the same batches were used in production of tablets. The same tabletting conditions were employed during tabletting to allow a comparison of their properties. The compaction properties of the granules are inferred from the data generated during the tabletting process. The tablet strength and dissolution properties of the tablets were also measured. The results obtained show that the granule batch size affects the strength and dissolution of the tablets formed. The tablets produced from large batches were found to be weaker and had a faster dissolution rate. The fill factor was also found to affect the tablet to tablet variation of a non-functional active pharmaceutical ingredient included in the feed powder. Tablets produced from larger batches show greater variation compared to those from smaller batches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research has shown that prior adaptation to a spatially circumscribed, oscillating grating results in the duration of a subsequent stimulus briefly presented within the adapted region being underestimated. There is an on-going debate about where in the motion processing pathway the adaptation underlying this distortion of sub-second duration perception occurs. One position is that the LGN and, perhaps, early cortical processing areas are likely sites for the adaptation; an alternative suggestion is that visual area MT+ contains the neural mechanisms for sub-second timing; and a third position proposes that the effect is driven by adaptation at multiple levels of the motion processing pathway. A related issue is in what frame of reference – retinotopic or spatiotopic – does adaptation induced duration distortion occur. We addressed these questions by having participants adapt to a unidirectional random dot kinematogram (RDK), and then measuring perceived duration of a 600 ms test RDK positioned in either the same retinotopic or the same spatiotopic location as the adaptor. We found that, when it did occur, duration distortion of the test stimulus was direction contingent; that is it occurred when the adaptor and test stimuli drifted in the same direction, but not when they drifted in opposite directions. Furthermore the duration compression was evident primarily under retinotopic viewing conditions, with little evidence of duration distortion under spatiotopic viewing conditions. Our results support previous research implicating cortical mechanisms in the duration encoding of sub-second visual events, and reveal that these mechanisms encode duration within a retinotopic frame of reference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

his paper uses fuzzy-set ideal type analysis to assess the conformity of European leave regulations to four theoretical ideal typical divisions of labour: male breadwinner, caregiver parity, universal breadwinner and universal caregiver. In contrast to the majority of previous studies, the focus of this analysis is on the extent to which leave regulations promote gender equality in the family and the transformation of traditional gender roles. The results of this analysis demonstrate that European countries cluster into five models that only partly coincide with countries’ geographical proximity. Second, none of the countries considered constitutes a universal caregiver model, while the male breadwinner ideal continues to provide the normative reference point for parental leave regulations in a large number of European states. Finally, we witness a growing emphasis at the national and EU levels concerning the universal breadwinner ideal, which leaves gender inequality in unpaid work unproblematized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To develop and manufacture both immediate and sustained release vaginal tablets containing the anticancer drug disulfiram, which has the potential to be used as a non-invasive treatment for cervical cancer. 
Methods: Disulfiram-loaded vaginal tablets were manufactured at pilot scale using the direct compression method. These tablets were tested in accordance with the European Pharmacopeia testing of solid dosage form guidelines. They were also tested using a biorelevant dissolution method as well as a dual-chambered release model designed to better mimic the dynamic nature of the vaginal vault.
Key findings: We have developed both immediate and sustained release vaginal tablets, which when manufactured at pilot scale are within the limits set by the European Pharmacopeia for the testing of solid dosage forms. Furthermore, these tablets are capable of releasing disulfiram in vitro using the dual-chambered release model at levels 25 000 times and 35 000 times greater than its IC50 concentration for the HeLa cervical cancer cell line. 
Conclusions: The successful pilot manufacture and testing of both the immediate and sustained release disulfiram-loaded vaginal tablets warrant further investigation, using an in-vivo model, to assess their potential for use as a non-invasive treatment option for cervical cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-velocity impact damage can drastically reduce the residual mechanical properties of the composite structure even when there is barely visible impact damage. The ability to computationally predict the extent of damage and compression after impact (CAI) strength of a composite structure can potentially lead to the exploration of a larger design space without incurring significant development time and cost penalties. A three-dimensional damage model, to predict both low-velocity impact damage and compression after impact CAI strength of composite laminates, has been developed and implemented as a user material subroutine in the commercial finite element package, ABAQUS/Explicit. The virtual tests were executed in two steps, one to capture the impact damage and the other to predict the CAI strength. The observed intra-laminar damage features, delamination damage area as well as residual strength are discussed. It is shown that the predicted results for impact damage and CAI strength correlated well with experimental testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the representation of judgements of stochastic independence in probabilistic logics. We focus on a relational logic where (i) judgements of stochastic independence are encoded by directed acyclic graphs, and (ii) probabilistic assessments are flexible in the sense that they are not required to specify a single probability measure. We discuss issues of knowledge representation and inference that arise from our particular combination of graphs, stochastic independence, logical formulas and probabilistic assessments.