129 resultados para absolute error


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the hypothesis that changes in nutritional status could be partly responsible for observed increases in myopia prevalence among Chinese children. DESIGN: Cross-sectional cohort study. METHODS: Rural Chinese secondary school children participating in a study of interventions to promote spectacle use were randomly sampled (20% of children with uncorrected vision >6/12 bilaterally, and 100% of remaining children) and underwent cycloplegic refraction with subjective refinement and measurement of height and weight. Stunting was defined according to the World Health Organization standard population. RESULTS: Among 3226 children in the sample, 2905 (90.0%) took part. Among 1477 children undergoing refraction, 1371 (92.8%) had height and weight measurements. These children had a mean age of 14.5 +/- 1.4 years, 59.8% were girls, and mean spherical equivalent refraction was -1.93 +/- 1.82 diopters. Stunting was present in 87 children (6.4%). While height was inversely associated with refractive error (RE) (taller children were more myopic) among boys (r = -0.147, P = .001), this disappeared when adjusting for age, and no such association was observed among girls. Neither girls nor boys with stunting differed significantly in refraction from children without stunting, and neither stunting nor height was associated with RE when adjusting for age, height, and parental education. The power of this study to have detected a 0.75 diopters difference in RE between children with and without stunting was 0.96. CONCLUSION: Results from this cross-sectional study are not consistent with the hypothesis that nutritional status is a determinant of RE in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: China is urbanizing rapidly, and the prevalence of myopia is high. This study was conducted to identify the reasons for observed differences in the prevalence of myopia among urban versus rural Chinese children. METHODS: All children with uncorrected acuity of 6/12 or worse and a 50% random sample of children with vision better than 6/12 at all secondary schools in mixed rural-urban Liangying Township, Guangdong, underwent cycloplegic refraction, and provided data on age, gender, parental education, weekly near work and time outdoors, and urban development level of respondents' neighborhoods (12-item questionnaire). Population density of 32 villages and urban zones in Liangying was calculated from census figures (mean population density, 217 persons/km(2); range, 94-957; mean for Guangdong, 486). RESULTS: Among 5844 eligible children, 4612 (78.9%) had parental consent and completed examinations; 2957 were refracted per protocol, and 2480 (83.9%) of these had questionnaire data. Those with completed examinations were more likely to be girls (P < 0.001), and questionnaire respondents were more myopic (P = 0.02), but otherwise did not differ significantly from nonrespondents. In multivariate models, older age (P < 0.001), more near work (P = 0.02), and higher population density (P = 0.003), but not development index, parental education, or time outdoors were significantly associated with more myopic refractive error. CONCLUSIONS: Higher population density appears to be associated with myopia risk, independent of academic activity, time spent outdoors, familial educational level, or economic development, factors that have been thought to explain higher myopia prevalence among urban children. Mechanisms for this apparent association should be sought.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test an educational intervention promoting the purchase of spectacles among Chinese children. DESIGN: Randomized, controlled trial. PARTICIPANTS: Children in years 1 and 2 of all 20 junior and senior high schools (ages 12-17 years) in 3 rural townships in Guangdong, China. METHODS: Children underwent visual acuity (VA) testing, and parents of participants with presenting VA worse than 6/12 in either eye improving by more than 2 lines with cycloplegic refraction were recommended to purchase glasses. Children at 10 randomly selected schools received a lecture, video, and classroom demonstration promoting spectacle purchase. MAIN OUTCOME MEASURES: Self-reported purchase of spectacles (primary outcome) and observed wear or possession of newly purchased glasses (secondary outcome) at follow-up examinations (mean, 219 ± 87 days after the baseline visit). RESULTS: Among 15 404 eligible children, examinations were completed for 6379 (74.6%) at intervention schools and 5044 (73.6%) at control schools. Spectacles were recommended for 2236 (35.1%) children at intervention schools and for 2212 (43.9%) at control schools. Of these, 417 (25.7%) intervention schools children and 537 (34.0%, P = 0.45) control schools children reported buying glasses. Predictors of purchase in regression models included female gender (P = 0.02), worse uncorrected VA (P < 0.001), and higher absolute value of refractive error (P = 0.001). Neither the rate of self-reported purchase of glasses or observed wear or possession of newly purchased glasses differed between control schools and intervention schools in mixed-effect logistic regression models. Among children not purchasing glasses, 21.7% had better-eye VA of worse than 6/18. CONCLUSIONS: An intervention based on extensive pilot testing and focus groups in the area failed to promote spectacle purchase or wear. The high burden of remaining uncorrected poor vision underscores the need to develop better interventions. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organization estimates that 13 million children aged 5-15 years worldwide are visually impaired from uncorrected refractive error. School vision screening programs can identify and treat or refer children with refractive error. We concentrate on the findings of various screening studies and attempt to identify key factors in the success and sustainability of such programs in the developing world. We reviewed original and review articles describing children's vision and refractive error screening programs published in English and listed in PubMed, Medline OVID, Google Scholar, and Oxford University Electronic Resources databases. Data were abstracted on study objective, design, setting, participants, and outcomes, including accuracy of screening, quality of refractive services, barriers to uptake, impact on quality of life, and cost-effectiveness of programs. Inadequately corrected refractive error is an important global cause of visual impairment in childhood. School-based vision screening carried out by teachers and other ancillary personnel may be an effective means of detecting affected children and improving their visual function with spectacles. The need for services and potential impact of school-based programs varies widely between areas, depending on prevalence of refractive error and competing conditions and rates of school attendance. Barriers to acceptance of services include the cost and quality of available refractive care and mistaken beliefs that glasses will harm children's eyes. Further research is needed in areas such as the cost-effectiveness of different screening approaches and impact of education to promote acceptance of spectacle-wear. School vision programs should be integrated into comprehensive efforts to promote healthy children and their families.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The separation of enantiomers and confirmation of their absolute configurations is significant in the development of chiral drugs. The interactions between the enantiomers of chiral pyrazole derivative and polysaccharide-based chiral stationary phase cellulose tris(4-methylbenzoate) (Chiralcel OJ) in seven solvents and under different temperature were studied using molecular dynamics simulations. The results show that solvent effect has remarkable influence on the interactions. Structure analysis discloses that the different interactions between two isomers and chiral stationary phase are dependent on the nature of solvents, which may invert the elution order. The computational method in the present study can be used to predict the elution order and the absolute configurations of enantiomers in HPLC separations and therefore would be valuable in development of chiral drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a new selective multi-carrier index keying in orthogonal frequency division multiplexing (OFDM) systems that opportunistically modulate both a small subset of sub-carriers and their indices. Particularly, we investigate the performance enhancement in two cases of error propagation sensitive and compromised deviceto-device (D2D) communications. For the performance evaluation, we focus on analyzing the error propagation probability (EPP) introducing the exact and upper bound expressions on the detection error probability, in the presence of both imperfect and perfect detection of active multi-carrier indices. The average EPP results in closedform are generalized for various fading distribution using the moment generating function, and our numerical results clearly show that the proposed approach is desirable for reliable and energy-efficient D2D applications.