261 resultados para Urine test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonsteroidal anti-inflammatory drug (NSAID)-induced increased intestinal permeability appears to be a prerequisite for NSAID enteropathy. It has been suggested that early metabolic events leading to the permeability changes may involve inhibition of glycolysis and the tricarboxylic acid cycle, in which case the coadministration of glucose and citrate (the substrates for these metabolic pathways) with indomethacin may afford some protection. The present study, using a combined intestinal absorption-permeability test including 3-O-methyl-D-glucose, D-xylose, L-rhamnose, and [51Cr]ethylene-diaminetetraacetic acid (EDTA) as test probes and the differential urine excretion ratio of [51Cr]-EDTA/L-rhamnose, showed that indomethacin (50 + 75 mg) increased intestinal permeability. A formulation of indomethacin containing 15 mg glucose and 15 mg citrate to each milligram of indomethacin did not increase intestinal permeability significantly above baseline values. When given alone with indomethacin, neither glucose nor citrate (45 mg to each milligram of indomethacin) had any protective effects. Pharmokinetic studies showed that the effects of glucose and citrate cannot be explained on the basis of altered drug absorption. These results suggest a new approach to reducing the small intestinal side effects of NSAIDs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. NGC 346-013 is a peculiar double-lined eclipsing binary in the Small Magellanic Cloud (SMC) discovered by the VLT-FLAMES survey of massive stars.

Relevância:

20.00% 20.00%

Publicador: