190 resultados para Tool Paths
Resumo:
Silicon carbide (SiC) is a material of great technological interest for engineering applications concerning hostile environments where silicon-based components cannot work (beyond 623 K). Single point diamond turning (SPDT) has remained a superior and viable method to harness process efficiency and freeform shapes on this harder material. However, it is extremely difficult to machine this ceramic consistently in the ductile regime due to sudden and rapid tool wear. It thus becomes non trivial to develop an accurate understanding of tool wear mechanism during SPDT of SiC in order to identify measures to suppress wear to minimize operational cost.
In this paper, molecular dynamics (MD) simulation has been deployed with a realistic analytical bond order potential (ABOP) formalism based potential energy function to understand tool wear mechanism during single point diamond turning of SiC. The most significant result was obtained using the radial distribution function which suggests graphitization of diamond tool during the machining process. This phenomenon occurs due to the abrasive processes between these two ultra hard materials. The abrasive action results in locally high temperature which compounds with the massive cutting forces leading to sp3–sp2 order–disorder transition of diamond tool. This represents the root cause of tool wear during SPDT operation of cubic SiC. Further testing led to the development of a novel method for quantitative assessment of the progression of diamond tool wear from MD simulations.
Resumo:
Background: There are many issues regarding the use of real patients in objective structured clinical examinations (OSCEs). In dermatology OSCE stations, standardised patients (SPs) with clinical photographs are often used. Temporary transfer tattoos can potentially simulate skin lesions when applied to an SP. This study aims to appraise the use of temporary malignant melanoma tattoos within an OSCE framework. Method: Within an 11-station OSCE, a temporary malignant melanoma tattoo was developed and applied to SPs in a 'skin lesion' OSCE station. A questionnaire captured the opinions of the candidate, SP and examiners, and the degree of perceived realism of each station was determined. Standard post hoc OSCE analysis determined the psychometric reliability of the stations. Results: The response rates were 95.9 per cent of candidates and 100 per cent of the examiners and SPs. The 'skin lesion' station achieved the highest realism score compared with other stations: 89.0 per cent of candidates felt that the skin lesion appeared realistic; only 28 per cent of candidates had ever seen a melanoma before in training. The psychometric performance of the melanoma station was comparable with, and in many instances better than, other OSCE stations. Discussion: Transfer tattoo technology facilitates a realistic dermatology OSCE station encounter. Temporary tattoos, alongside trained SPs, provide an authentic, standardised and reliable experience, allowing the assessment of integrated dermatology clinical skills.
Resumo:
Here we describe the development of the MALTS software which is a generalized tool that simulates Lorentz Transmission Electron Microscopy (LTEM) contrast of magnetic nanostructures. Complex magnetic nanostructures typically have multiple stable domain structures. MALTS works in conjunction with the open access micromagnetic software Object Oriented Micromagnetic Framework or MuMax. Magnetically stable trial magnetization states of the object of interest are input into MALTS and simulated LTEM images are output. MALTS computes the magnetic and electric phases accrued by the transmitted electrons via the Aharonov-Bohm expressions. Transfer and envelope functions are used to simulate the progression of the electron wave through the microscope lenses. The final contrast image due to these effects is determined by Fourier Optics. Similar approaches have been used previously for simulations of specific cases of LTEM contrast. The novelty here is the integration with micromagnetic codes via a simple user interface enabling the computation of the contrast from any structure. The output from MALTS is in good agreement with both experimental data and published LTEM simulations. A widely-available generalized code for the analysis of Lorentz contrast is a much needed step towards the use of LTEM as a standardized laboratory technique.
Resumo:
Tetrodotoxin (TTX) is a potent neurotoxin emerging in European waters due to increasing ocean temperatures. Its detection in seafood is currently performed as a consequence of using the Association of Analytical Communities (AOAC) mouse bioassay (MBA) for paralytic shellfish poisoning (PSP) toxins, but TTX is not monitored routinely in Europe. Due to ethical and performance-related issues associated with this bioassay, the European Commission has recently published directives extending procedures that may be used for official PSP control. An AOAC-accredited high-performance liquid chromatography (HPLC) method has now been accepted by the European Union as a first action screening method for PSP toxins to replace the MBA. However, this AOAC HPLC method is not capable of detecting TTX, so this potent toxin would be undetected; thereby, a separate method of analysis is required. Surface plasmon resonance (SPR) optical biosensor technology has been proven as a potential alternative screening method to detect PSP toxins in seafood. The addition of a similar SPR inhibition assay for TTX would complement the PSP assay in removing the MBA. The present report describes the development and single laboratory validation in accordance with AOAC and IUPAC guidelines of an SPR method to be used as a rapid screening tool to detect TTX in the sea snail Charonia lampas lampas, a species which has been implicated in 2008 in the first case of human TTX poisoning in Europe. As no current regulatory limits are set for TTX in Europe, single laboratory validation was undertaken using those for PSP toxins at 800 µg/kg. The decision limit (CCa) was 100 µg/kg, with the detection capability (CCß) found to be =200 µg/kg. Repeatability and reproducibility were assessed at 200, 400, and 800 µg/kg and showed relative standard deviations of 8.3, 3.8, and 5.4 % and 7.8, 8.3, and 3.7 % for both parameters at each level, respectively. At these three respective levels, the recovery of the assay was 112, 98, and 99 %.
Resumo:
Background: Clinical supervision takes place once the newly qualified nurse is employed in clinical practice. However, often the variety and diversity of nursing jobs can result in a hit and miss delivery of supervision training. By introducing training uniformly at undergraduate stage a more seamless transition may occur (McColgan K, Rice C. 2012).
There is an increased interest in higher education in the use of online learning resources for students. As part completion of a DNP an App. for training students in clinical supervision was developed.
Aim: The creation of a clinical supervision training App. for use in undergraduate nursing.
Objectives:
•To develop a teaching tool that is up to date, current and easily accessible to students.
•To introduce supervision training for undergraduate nursing students
•To motivate the undergraduate nursing student to identify examples from their clinical experience to encourage change and promote professional development.
Approach:
Stage 1
In 2010/11 informal inquiries with senior nurses regarding the introduction of supervision training in undergraduate nursing
Stage 2
A review of UK supervision training.
Stage 3
Template production of teaching tool.
Stage 4
Collaboration with a computer technician to transfer multimedia outputs onto an App.
Stage 5
App. piloted with lecturers (n=4) and post registration students (n=20).
Stage 6
Minor alterations made to App. design template
Stage 7
App. included in an experimental study looking at online learning versus blended learning June 2013 (n=61, n=63)
Conclusion: A collaborative approach to the development of any educational programme is essential to ensure the success of the final teaching product (McCutcheon 2013). The end result is that this App. could be:
•Made available to nurses in the UK.
•Adapted to suit other healthcare professionals and students.
•Used as a prototype for other healthcare related subjects.
McColgan K., Rice C. (2012) An online training resource for clinical supervision. Nursing Standard, 26(24) 35-39.
McCutcheon K. (2013) Development of a multi-media book for clinical supervision training in an undergraduate nursing programme. Journal of Nursing Education and Practice, 3(5) 31-38.
Resumo:
Previous research on damage detection based on the response of a structure to a moving load has reported decay in accuracy with increasing load speed. Using a 3D vehicle – bridge interaction model, this paper shows that the area under the filtered acceleration response of the bridge increases with increasing damage, even at highway load speeds. Once a datum reading is established, the area under subsequent readings can be monitored and compared with the baseline reading, if an increase is observed it may indicate the presence of damage. The sensitivity of the proposed approach to road roughness and noise is tested in several damage scenarios. The possibility of identifying damage in the bridge by analysing the acceleration response of the vehicle traversing it is also investigated. While vehicle acceleration is shown to be more sensitive to road roughness and noise and therefore less reliable than direct bridge measurements, damage is successfully identified in favourable scenarios.
Resumo:
This paper presents a 3D simulation system which is employed in order to predict cutting forces and tool deflection during end-milling operation. In order to verify the accuracy of 3D simulation, results (cutting forces and tool deflection) were compared with those based on the theoretical relationships, in terms of agreement with experiments. The results obtained indicate that the simulation is capable of predicting the cutting forces and tool deflection.