129 resultados para Silicone elastomer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine the incidence of giant retinal tear (GRT) in the United Kingdom and to provide epidemiologic data, clinical characteristics, treatment methods, and short-term outcomes in affected and fellow eyes. METHODS. Patients with a newly developed GRT (90° or greater in circumferential extent associated with posterior vitreous detachment) were identified prospectively over a 13-month period (January 2007-January 2008, inclusive) by active surveillance through the British Ophthalmic Surveillance Unit. Questionnaire-based data were obtained from reporting ophthalmologists at baseline and 12 months. RESULTS. Sixty patients (62 eyes) developed a new GRT, giving a U.K. annual incidence of 0.094 (95% CI 0.072-0.120) cases or 0.091 (95% CI 0.069-0.117) patients per 100,000. The GRTs were mostly idiopathic (54.8%), affected middle-aged (mean, 42.2 years), white British (93.3%) males (71.7%), with presenting vision worse than 20/40 in 59.7%, foveal detachment in 45.2%, and proliferative vitreoretinopathy of grade C (PVR-C) or worse in 11.3%. Treatment in most was managed by pars plana vitrectomy (93.5%) with laser retinopexy (52.5%) and silicone oil endotamponade (75.8%). Prophylactic 360° laser or cryotherapy was applied to 39.0% of the fellow eyes. At mean follow-up of 11.3 months, eventual retinal reattachment was attained in 94.7%, although only 42.1% achieved vision of =20/40. Neither GRT nor RD developed in any of the 19 nontraumatic, noniatrogenic, prophylactically treated fellow eyes. CONCLUSIONS. This study is the first population-based prospective effort to evaluate the epidemiology of GRT. Although onlya minority presented with PVR-C and high retinal reattachment rates were achieved, fewer than half had vision sufficient for driving in the GRT eye.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim - To describe a new surgical technique for foveal relocation, and to report the outcome in nine patients treated with this procedure. Methods - Nine consecutive patients with subfoveal choroidal neovascular membranes (CNVMs) secondary to age related macular degeneration underwent foveal relocation surgery by redistribution of the neurosensory retina (RNR). The technique involved induction of a retinal detachment via a single retinotomy, relocation of the fovea by 'sweeping' the retinal tissue with a retinal brush, and stabilisation of the retina in its new location using perfluorocarbon liquid peroperatively and silicone oil postoperatively. Results - In eight of nine eyes successful relocation of the fovea was achieved; in one eye the CNVM remained in a subfoveal location postoperatively. Visual acuity improved in two eyes, remained unchanged in three, and decreased in four eyes after a median follow up of 4 months (range 2.5-6 months). Complications included rupture of a foveal cyst with the development of a macular hole in one eye and epimacular membrane formation in another eye. In two eyes, macular retinal vessel closure occurred at the time of laser photocoagulation; one of these eyes later developed cystoid macular oedema and the other an epiretinal membrane. Recurrence of the CNVM was observed in one eye, but was controlled with further laser treatment. Conclusions - Foveal relocation by RNR appears to be feasible, obviating the need for extensive retinotomies or scleral shortening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in corneal graft technology, including donor tissue retrieval, storage and surgical techniques, have greatly improved the clinical outcome of corneal grafts. Despite these advances, immune mediated corneal graft rejection remains the single most important cause of corneal graft failure. Several host factors have been identified as conferring a "high risk" status to the host. These include: more than two quadrant vascularisation, with associated lymphatics, which augment the afferent and efferent arc of the immune response; herpes simplex keratitis; uveitis; silicone oil keratopathy; previous failed (rejected) grafts; "hot eyes"; young recipient age; and multiple surgical procedures at the time of grafting. Large grafts, by virtue of being closer to the host limbus, with its complement of vessels and antigen-presenting Langerhans cells, also are more susceptible to rejection. The diagnosis of graft rejection is entirely clinical and in its early stages the clinical signs could be subtle. Graft rejection is largely mediated by the major histocompatibility antigens, minor antigens and perhaps blood group ABO antigens and some cornea-specific antigens. Just as rejection is mediated by active immune mediated events, the lack of rejection (tolerance) is also sustained by active immune regulatory mechanisms. The anterior chamber associated immune deviation (ACAID) and probably, conjunctiva associated lymphoid tissue (CALT) induced mucosal tolerance, besides others, play an important role. Although graft rejection can lead to graft failure, most rejections can be readily controlled if appropriate management is commenced at the proper time. Topical steroids are the mainstay of graft rejection management. In the high-risk situations however, systemic steroids, and other immunosuppressive drugs such as cyclosporin and tacrolimus (FK506) are of proven benefit, both for treatment and prevention of rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A giant retinal tear (GRT) is a full-thickness neurosensory retinal break that extends circumferentially around the retina for three or more clock hours in the presence of a posteriorly detached vitreous. Its incidence in large population-based studies has been estimated as 1.5% of rhegmatogenous retinal detachments, with a significant male preponderance, and bilaterality in 12.8%. Most GRTs are idiopathic, with trauma, hereditary vitreoretinopathies and high myopia each being causative in decreasing frequency. The vast majority of GRTs are currently managed with a pars plana vitrectomy; the use of adjunctive circumferential scleral buckling is debated, but no studies have shown a clear anatomical or visual advantage with its use. Similarly, silicone oil tamponade does not influence long-term outcomes when compared with gas. Primary and final retinal reattachment rates are achieved in 88% and 95% of patients, respectively. Even when the retina remains attached, however, visual recovery may be limited. Furthermore, fellow eyes of patients with a GRT are at higher risk of developing retinal tears and retinal detachment. Prophylactic treatment under these circumstances may be considered but there is no firm evidence of its efficacy at the present time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of addition of reinforcing carbon nanotubes (CNTs) into hydrogenated nitrile-butadiene rubber (HNBR) matrix on the mechanical, dynamic viscoelastic, and permeability properties were studied in this investigation. Different techniques of incorporating nanotubes in HNBR were investigated in this research. The techniques considered were more suitable for industrial preparation of rubber composites. The nanotubes were modified with different surfactants and dispersion agents to improve the compatibility and adhesion of nanotubes on the HNBR matrix. The effects of the surface modification of the nanotubes on various properties were examined in detail. The amount of CNTs was varied from 2.5 to 10 phr in different formulations prepared to identify the optimum CNT levels. A detailed analysis was made to investigate the morphological structure and mechanical behavior at room temperature. The viscoelastic behavior of the nanotube filler elastomer was studied by dynamic mechanical thermal analysis (DMTA). Morphological analysis indicated a very good dispersion of the CNTs for a low nanotube loading of 3.5 phr. A significant improvement in the mechanical properties was observed with the addition of nanotubes. DMTA studies revealed an increase in the storage modulus and a reduction in the glass-transition temperature after the incorporation of the nanotubes. Further, the HNBR/CNT nanocomposites were subjected to permeability studies. The studies showed a significant reduction in the permeability of nitrogen gas. Copyright © 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The azo dye, basic blue 66 (BB66) is used in a photocatalyst activity indicator ink (paii) to assess the activity of low activity photocatalytic surfaces, such as commercial photocatalytic tiles and silicone contaminated self-cleaning glass. The BB66 paii is shown to respond much faster than a previously reported, resazurin (Rz) based paii, i.e. the use of a BB66 paii on low activity self-cleaning tiles was found to be >6 times faster than the Rz paii. The BB66 paii is also shown to be effective at assessing the activity of piece of commercial self-cleaning glass contaminated with a coating of silicone, on which the Rz ink, in contrast, failed to show any significant change in colour over the same time period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel manufacturing process for fabricating microneedle arrays (MN) has been designed and evaluated. The prototype is able to successfully produce 14 × 14 MN arrays and is easily capable of scale-up, enabling the transition from laboratory to industry and subsequent commercialisation. The method requires the custom design of metal MN master templates to produce silicone MN moulds using an injection moulding process. The MN arrays produced using this novel method was compared with centrifugation, the traditional method of producing aqueous hydrogel-forming MN arrays. The results proved that there was negligible difference between either methods, with each producing MN arrays with comparable quality. Both types of MN arrays can be successfully inserted in a skin simulant. In both cases the insertion depth was approximately 60% of the needle length and the height reduction after insertion was in both cases approximately 3%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, micro-joining of plastic parts to metal parts in medical devices is achieved by using medical adhesives, For example, pacemakers, defibrillators and neurological stimulators are designed using silicone adhesive to seal the joint between the polyurethane connector module and the titanium can [1]. Nevertheless, the use of adhesive is problematic because it requires a long time to cure and has high tendency to produce leachable products which might be harmful to the human body. An alternative for directly joining plastics to metal without adhesive is therefore required. Laser transmission joining (LTJ) is growing in importance, and has the potential to gain the niche in micro-fabrication of plastics-metal hybrid joints for medical device applications. The possibility of directly joining plastics to metal by LTJ technique have been demonstrated by a number of studies in recent literature [2]. The widely-accepted understanding of LTJ between plastics and metal is that generation and rapid expansion of micro-bubbles at the plastics-metal interface exert high local pressure to press the melted plastics towards the metal surface features during the laser processing [2]. This subsequently creates the plastics-metal hybrid joint by the mechanisms of mechanical interlocking as well as chemical and physical bonds between the plastics and metal surfaces. Although the micro-bubbles can help promote the mechanical interlocking effect to increase the joint strength, the creation of bubble is a random and complex process depending on the complicated interactions between the laser intensity, thermal degradation properties of plastics, surface temperature and topographical features of metal. In an ideal situation, it is desirable to create the hybrid plastics-metal joint without bubbles. However, the mechanical performance of the hybrid plastics-metal joint without bubbles is still unknown, and systematic comparison between the hybrid joints with and without bubbles is lacking in literature. This becomes the objective of this study. In this work, the laser process parameters were carefully chosen from a preliminary study, such that different hybrid joints: with and without bubbles can be produced and compared. Biocompatible PET and commercially pure Ti were selected as materials for laser joining.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deposition of stiff and strong coatings onto porous templates offers a novel strategy for fabricating macroscale materials with controlled architectures at the micro- and nanoscale. Here, layer-by-layer assembly is utilized to fabricate nanocomposite-coated foams with highly customizable properties by depositing polymer–nanoclay coatings onto open-cell foam templates. The compressive mechanical behavior of these materials evolves in a predictable manner that is qualitatively captured by scaling laws for the mechanical properties of cellular materials. The observed and predicted properties span a remarkable range of density-stiffness space, extending from regions of very soft elastomer foams to very stiff, lightweight honeycomb and lattice materials.