166 resultados para Plastic surgery
Resumo:
Background: Cataract extraction is the most commonly performed surgery in the National Health Service. Myopia increases the risk of postoperative rhegmatogenous retinal detachment (RRD). The aim of this study was to determine the incidence and rate of RRD seven years after cataract extraction in highly myopic eyes. Methods: Retrospective review was performed of notes of all high myopes (axial length 26.0 mm or more) who underwent cataract extraction during the study period in one centre. Results: 84 eyes met the study criteria. Follow-up time from surgery was 93 to 147 months (median 127 months). The average axial length was 28.72 mm (sd 1.37). Two eyes developed post-operative RRD; the incidence was 2.4% and the rate one RRD per 441.6 person-years. The results of 15 other studies on the incidence of RRD after cataract extraction in high myopia were pooled and combined with our estimate. Conclusion: Both patients in our study who developed RRD had risk factors for this complication as well as high myopia. Risk factors are discussed in the light of our results and the pooled estimate. Our follow-up time is longer than most. Future case series should calculate rates to allow meaningful comparison of case series. © The Ulster Medical Society, 2009.
Resumo:
Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.
Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.
Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
Breast augmentation for cosmetic purposes is an increasingly common procedure in the USA and UK. In the USA in 2003, a total of 254 140 breast augmentation procedures were carried out [American Society of Plastic Surgeons, http://www.plasticsurgery.org/newsroom/ Procedural-Statistics-Press-Kit-Index.cfm9-1-2005; 2006.(1)]. It has been previously estimated that between 1 and 1.5 million women in the USA have prosthetic breast implants [Cook RR, Delongchamp RR, Woodbury M, et at. The prevalence of women with breast implants in the United States, 1989. J Clin Epidemiol 1995;48:519-25.(2)]. The UK National Breast Implant Registry has recorded a rise in the numbers of women receiving breast implants, with over 13 000 procedures registered in 2001; an estimated 77% of these were for cosmetic purposes. No association has been found between the presence of breast implants in a breast and an increased risk of breast cancer, and this subject has been comprehensively reviewed elsewhere [Hoshaw SJ, Klein PJ, Clark BD, et al. Breast implants and cancer: causation, delayed detection, and survival. Plast Reconstr Surg 2001; 107:1393-407.(3)]. However, as the population of women with breast implants ages, an increasing number of them will develop breast cancer; a reflection of the fact that the incidence of the disease increases with increasing age. Debate continues on the effect of breast implants on the efficacy of mammography in diagnosing breast cancer, and the role of other imaging techniques for this purpose, as well as the limitations that the presence of implants place on percutaneous biopsy techniques. We review the Literature on the radiological and tissue diagnosis of breast cancer in women with a history of previous augmentation mammaplasty. (c) 2007 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
The incidence of breast cancer in women with implants is increasing and will continue to do so for the foreseeable future due to the marked increase in breast implant insertion in recent years. Undoubtedly many of these women will wish to know whether the presence of implants worsens the prognosis of their breast cancer. Furthermore, the clinical management of such patients may be difficult, as aesthetic results are likely to be a major concern for women who have already undergone cosmetic surgery to the breast. There is no consensus on surgical approach to this scenario. This article reviews the literature on the prognosis of breast cancer patients with a history of augmentation mammoplasty and examines the available data regarding their surgical treatment. (c) 2007 Published by Elsevier Ltd on behalf of British Association of Plastic, Reconstructive and Aesthetic Surgeons.
Resumo:
Previous research with parents of preterm and low-birth weight infants admitted to the Neonatal Intensive Care Unit (NICU) has indicated the following: (i) parents are at risk of experiencing stress associated with the NICU environment; (ii) parents are at risk of short- and longer-term psychological distress; and (iii) the family is at risk of longer-term stress and strain. However, parents of infants admitted to the NICU for surgery are an under-researched population. This paper provides an overview of the current literature in relation to this issue. The results highlight the paucity of research conducted with parents of infants admitted to the NICU for surgery. A number of gaps and limitations were also identified in the current literature, including a lack of examination why some parents cope better than others, and a focus solely on parents of preterm and low birth weight infants. To conclude, further research with parents of infants who had surgery in the first few weeks of life is needed. Such information could help inform clinicians caring for these infants and their families, and would enable identification of those parents and families most at risk.
Resumo:
No abstract available
Resumo:
Aim: Foreskin surgical procedures such as circumcision, prepuceplasty, frenuloplasty, dorsal slit, reduction of paraphimosis etc. in the adult male is usually performed by both general surgeons and urologists. Our aim was to evaluate the acceptance of performing these procedures in the day procedure unit or in the emergency unit under penile block.
Method: Fifty patients who underwent foreskin surgeries under local anaesthetic (LA) were evaluated with their experience. Twenty patients who underwent circumcision, 20 patients who underwent foreskin preserving operations such as frenuloplasty or prepuceplasty and 10 patients who underwent other procedures such as reduction of paraphimosis (five) and dorsal slit (five) were included inthe study. The patients were asked about their symptoms such as pain or discomfort during local infiltration of lignocaine, any discomfort during the actual procedure, post-operative discomfort and general acceptance. All the patients were given penile block using smaller size needle (25 gauge, 5/8th inch orange sterile luer slip hypodermic needle) and 1% plain lignocaine. Thirty doctors from general surgery (10), urology (10) and emergency medicine (10) participated in the survey. They were asked about their opinion, confidence and preference about performing foreskin surgical procedures under LA. This included both junior trainees, middle grade doctors and consultants. The majority of middle grade doctors and consultants were fairly confident in performing procedures under LA, whereas the junior trainees in surgery, urology and emergency were lacking confidence.
Conclusion: Penile block is a safe and effective way ofproviding sufficient anaesthesia for foreskin surgeries. Thetechnique is easy to learn. It reduces post-operative pain aswell. It can reduce the risk and cost of administering generalanaesthesia. doctors who are in training surgical specialityand emergency medicine should be encouraged to learnthe principles and technique in administering penile block.
Resumo:
Milling of plant and soil material in plastic tubes, such as microcentrifuge tubes, over-estimates carbon (C) and under-estimates nitrogen (N) concentrations due to the introduction of polypropylene into milled samples, as identified using Fourier-transform infra-red spectroscopy.
This study compares C and N concentrations of roots and soil milled in microcentrifuge tubes versus stainless steel containers, demonstrating that a longer milling time, greater milling intensity, smaller sample size and inclusion of abrasive sample material all increase polypropylene contamination from plastic tubes leading to overestimation of C concentrations by up to 8 % (0.08 g g(-1)).
Erroneous estimations of C and N, and other analytes, must be assumed after milling in plastic tubes and milling methods should be adapted to minimise such error.
Resumo:
Solar water disinfection (SODIS) is a well-established inexpensive means of water disinfection in developing countries, but lacks an indicator to illustrate its end-point. A study of the solar UV dosage required for SODIS, in order to achieve a bacteria concentration below the detection limit for: Escherichia coli, Enterococcus spp. and Clostridium perfringens, in water in PET bottles, PE and PE/EVA bags showed disinfection to be most efficient in PE bags, with a solar UV (290–385 nm) dose of 389 kJ m−2 required. In parallel to the disinfection experiments, a range of polyoxometalate, semiconductor photocatalysis and photodegradable dye-based solar UV dosimeter indicators were tested under the same solar UV irradiation conditions. All three types of dosimeter produced indicators that largely and significantly change colour upon exposure to 389 kJ m−2 solar UV; further indicators are reported which change colour at higher doses and hence would be suitable for the less efficient SODIS containers tested. All indicators tested were robust, easy to use and inexpensive so as not to add significantly to the attractive low cost of SODIS. Furthermore, whilst semiconductor photocatalyst and photodegradable dye based indicators are disposable, one-use systems, the polyoxometalate based indicators recover colour in the dark overnight, allowing them to be reused, and hence further decreasing the cost of using indicators during the implementation of the SODIS method.