109 resultados para ring contractions
Resumo:
The paper reports of a flat spiral phase plate structure based on reflectarray frequency selective surface, FSS, technology for the generation of helical far-field radiation patterns with circular polarization (CP) properties. Double split ring slot FSS is used as a means for adjusting the phase across the reflectarray. Simulations presented demonstrate generation of reflected helical beams at 10 GHz for CP wave incident on the structure. The far-field measurements are in a good agreement with the simulations and demonstrate a null of -11dB in the centre of the radiation pattern attributed to the helical wavefront.
Resumo:
Administration of biomacromolecular drugs in effective quantities from conventional vaginal rings is hampered by poor drug permeability in the polymers from which rings are commonly constructed. Here, we report the formulation development and testing of rod insert rings for sustained release of the candidate antiretroviral peptides T-1249 and JNJ54310516-AFP (JNJ peptide), both of which have potential as HIV microbicides. Rod inserts were prepared comprising antiviral peptides T-1249 or JNJ peptide in combination with a hydrophilic excipient (sodium chloride, sodium glutamate, lactose or zinc acetate) dispersed at different loadings within a medical grade silicone elastomer. The inserts were tested for weight change and swelling when immersed in simulated vaginal fluid (SVF). Dye migration into the inserts was also assessed visually over 28 days. In vitro release of T-1249 and JNJ peptide from rings containing various insert types was tested. Weight change and degree of swelling of rods immersed in SVF was dependent on the type and concentration of excipient present. The rods displayed the following rank order in terms of weight change: sodium glutamate > zinc acetate ≈ sodium chloride > lactose. The weight change and degree of swelling of the inserts did not correlate with the level of dye uptake observed. In vitro release of T-1249 was improved through addition of lactose, sodium chloride and sodium glutamate, while release of JNJ peptide was improved through addition of sodium chloride or sodium glutamate. Sustained release of hydrophobic peptides can be achieved using a rod insert ring design formulated to include a hydrophilic excipient. Release rates were dependent upon the type of excipient used. The degree of release improvement with different inserts partially reflects their ability to imbibe surrounding fluid and swell in aqueous environments.
Resumo:
We report the first detection of a gap and a ring in dust continuum emission from the protoplanetary disk around TW Hya, using the Atacama Large Millimeter/Submillimeter Array. The gap and ring are located at 25 and 41 AU from the central star, respectively, and are associated with the CO snowline at ~ 30AU. The gap width and depth are 15AU at the maximum and 23% at the minimum, respectively, regarding that the observations are limited to an angular resolution of ~ 15AU. In addition, we detect a decrement in CO line emission down to ~ 10AU, indicating freeze-out of gas-phase CO onto grain surfaces and possible subsequent surface reactions to form larger molecules. According to theoretical studies, the gap could be caused by gravitational interaction between the disk gas and a planet with a mass less than super-Neptune (2 Neptune mass), or result from destruction of large dust aggregates due to the sintering of CO ice.
Resumo:
This paper proposes a wideband equivalent circuit model for a twisted split ring frequency selective surface (FSS). Such surfaces can be used for modelling and design of polarisation sensitive surfaces such as circularly polarized selective surfaces as well as structures with asymmetric transmission. The proposed model is based extraction of equivalent circuit parameters from a single split ring (SRR) FSS and magnetic coupling from periodic eigenmode analysis of the coupled SRR. The resulting equivalent circuit model demonstrates excellent agreement with full-wave simulations.