178 resultados para objective tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow responsive passive samplers offer considerable potential in nutrient monitoring in catchments; bridging the gap between the intermittency of grab sampling and the high cost of automated monitoring systems. A commercially available passive sampler was evaluated in a number of river systems encapsulating a gradient in storm response, combinations of diffuse and point source pressures, and levels of phosphorus and nitrogen concentrations. Phosphorus and nitrogen are sequestered to a resin matrix in a permeable cartridge positioned in line with streamflow. A salt tracer dissolves in proportion to advective flow through the cartridge. Multiple deployments of different cartridge types were undertaken and the recovery of P and N compared with the flow-weighted mean concentration (FWMC) from high-resolution bank-side analysers at each site. Results from the passive samplers were variable and largely underestimated the FWMC derived from the bank-side analysers. Laboratory tests using ambient river samples indicated good replication of advective throughflow using pumped water, although this appeared not to be a good analogue of river conditions where flow divergence was possible. Laboratory tests also showed good nutrient retention but not elution and these issues appeared to combine to limit the utility in ambient river systems at the small catchment scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In astrophysical systems, radiation-matter interactions are important in transferring energy and momentum between the radiation field and the surrounding material. This coupling often makes it necessary to consider the role of radiation when modelling the dynamics of astrophysical fluids. During the last few years, there have been rapid developments in the use of Monte Carlo methods for numerical radiative transfer simulations. Here, we present an approach to radiation hydrodynamics that is based on coupling Monte Carlo radiative transfer techniques with finite-volume hydrodynamical methods in an operator-split manner. In particular, we adopt an indivisible packet formalism to discretize the radiation field into an ensemble of Monte Carlo packets and employ volume-based estimators to reconstruct the radiation field characteristics. In this paper the numerical tools of this method are presented and their accuracy is verified in a series of test calculations. Finally, as a practical example, we use our approach to study the influence of the radiation-matter coupling on the homologous expansion phase and the bolometric light curve of Type Ia supernova explosions. © 2012 The Authors Monthly Notices of the Royal Astronomical Society © 2012 RAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine if phenotypic subtypes exist in Stargardt macular dystrophy-fundus flavimaculatus (SMD-FFM). Methods: A cross-sectional study of 63 patients with autosomal recessive SMD-FFM was undertaken. The age of onset, duration of symptoms, visual acuity, and clinical features on fundus examination, color fundus photographs, and fundus autofluorescence images were recorded. Electrophysiological tests, including pattern, focal, and full-field electroretinogram (ERG), electro-oculogram, and color-contrast sensitivity measurement, were also performed. Results: Based on electrophysiological attributes (ERG), patients with SMD-FFM could be classified into 3 groups. In group 1, there was severe pattern ERG abnormality with normal scotopic and full-field ERGs. In group 2, there was additional loss of photopic function, and in group 3, there was loss of both photopic and scotopic function. Differences in scotopic or photopic function among groups were not explained on the basis of differences in age of onset or duration of disease. Conclusions: Patients with SMD-FFM can be classified into 3 groups based on the absence or presence of generalized loss of either photopic or photopic and scotopic function. It appears that these 3 groups may represent distinct phenotypic subtypes in SMD-FFM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a step-wise approach for the understanding and interpretation of Humphrey's SITA visual field tests. The goal of this article is to help the reader to differentiate between non-specific abnormalities of the visual field and changes of the visual field that are suggestive of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to estimate costs and quality of life (QoL) of late-stage glaucoma patients in 4 European countries. Methods: Retrospective review of medical charts of patients with POAG who were followed in a low-vision or vision rehabilitation center in one of 4 countries for at least 1 year was used to determine patient characteristics, health status, and health care resource use. Visual impairment was measured by best-corrected visual acuity (Snellen score). Patients were also interviewed over the telephone in order to assess their health-related QoL (using EuroQol EQ-5D) and use of resources including: the number of visits to rehabilitation centers, visits to hospital and non-hospital specialists, the use of low-vision devices, medication, tests, and the use of hired home help. The costs associated with resource use were calculated from the perspective of a third-party payer of health and social care based on resource usage and unit costs in each country. Results: Patients undergoing visual rehabilitation in France (n=21), Denmark (n=59), Germany (n=60), and the United Kingdom (n=22) were identified, interviewed and had their medical charts reviewed. Annual maintenance costs of late-stage glaucoma amounted to €830 (±445) on average. Average home help costs were more than 3 times higher. QoL, on average, was 0.65 (±0.28). QoL was positively correlated with the level of visual acuity in the patients' best eye. On the other hand, visual acuity was also positively correlated to health care costs, but negatively correlated to costs of home help. Conclusions: The study was limited by its observational, uncontrolled design. The finding that late-stage glaucoma is associated with higher home help costs than health care maintenance costs suggests that potential savings from a better preventive treatment are to be found for social care payers rather than health care payers. © 2008 Informa UK Ltd All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to produce phage display-derived binders with the ability to distinguish Listeria monocytogenes from other Listeria spp., which may have potential utility to enhance detection of Listeria monocytogenes. To obtain binders with the desired binding specificity a series of surface and solution phage-display biopannings were performed. Initially, three rounds of surface biopanning against gamma-irradiated L. monocytogenes serovar 4b cells were performed followed by an additional surface biopanning round against L. monocytogenes 4b which included prior subtraction biopanning against gamma-irradiated L. innocua cells. In an attempt to further enhance binder specificity for L. monocytogenes 4b two rounds of solution biopanning were performed, both rounds included initial subtraction solution biopanning against L. innocua. Subsequent evaluations were performed on the phage clones by phage binding ELISA. All phage clones tested from the second round of solution biopanning had higher specificity for L. monocytogenes 4b than for L. innocua and three other foodborne pathogens (Salmonella spp., Escherichia coli and Campylobacter jejuni). Further evaluation with five other Listeria spp. revealed that one phage clone in particular, expressing peptide GRIADLPPLKPN, was highly specific for L. monocytogenes with at least 43-fold more binding capability to L. monocytogenes 4b than to any other Listeria sp. This proof-of-principle study demonstrates how a combination of surface, solution and subtractive biopanning was used to maximise binder specificity. L. monocytogenes-specific binders were obtained which could have potential application in novel detection tests for L. monocytogenes, benefiting both the food and medical industries. © 2013 Morton et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber-reinforced polymer (FRP) hollow tubes are used in structural applications, such as utility poles and pipelines. Concrete-filled FRP tubes (CFFTs) are also used as piles and bridge piers. Applications such as poles and marine piles are typically governed by cyclic bending. In this paper, the fatigue behavior of glass-FRP filament-wound tubes is studied using coupons cut from the tubes. Several coupon configurations were first examined in 24 tension and five compression monotonic loading tests. Fatigue tests were then conducted on 81 coupons to examine several parameters; namely, loading frequency as well as maximum-to-ultimate (max ult) and minimum-to-maximum (min max) stress ratios, including tension tension and tension compression, to simulate reversed bending. The study demonstrated the sensitivity of test results and failure mode to coupon configuration. The presence of compression loads reduced fatigue life, while increasing load frequency increased fatigue life. Stiffness degradation behavior was also established. To achieve at least one million cycles, it is recommended to limit (max ult) to 0.25. Models were used to simulate stiffness degradation and fatigue life curve of the tube. Fatigue life predictions of large CFFT beams showed good correlation with experimental results. © 2008 ASCE.