This paper explores how the surface permeability of sandstone blocks changes over time in response to repeated salt weathering cycles. Surface permeability controls the amount of moisture and dissolved salt that can penetrate in and facilitate decay. Connected pores permit the movement of moisture (and hence soluble salts) into the stone interior, and where areas are more or less permeable soluble salts may migrate along preferred pathways at differential rates. Previous research has shown that salts can accumulate in the near-surface zone and lead to partial pore blocking which influences subsequent moisture ingress and causes rapid salt accumulation in the near-surface zone.
Two parallel salt weathering simulations were carried out on blocks of Peakmoor Sandstone of different volumes. Blocks were removed from simulations after 2, 5, 10, 20 and 60 cycles. Permeability measurements were taken for these blocks at a resolution of 20 mm, providing a grid of 100 permeability values for each surface. The geostatistical technique of ordinary kriging was applied to the data to produce a smoothed interpolation of permeability for these surfaces, and hence improve understanding of the evolution of permeability over time in response to repeated salt weathering cycles.
Results illustrate the different responses of the sandstone blocks of different volumes to repeated salt weathering cycles. In both cases, after an initial subtle decline in the permeability (reflecting pore blocking), the permeability starts to increase — reflected in a rise in mean, maximum and minimum values. However, between 10 and 20 cycles, there is a jump in the mean and range permeability of the group A block surfaces coinciding with the onset of meaningful debris release. After 60 cycles, the range of permeability in the group A block surface had increased markedly, suggesting the development of a secondary permeability. The concept of dynamic instability and divergent behaviour is applied at the scale of a single block surface, with initial small-scale differences across a surface having larger scale consequences as weathering progresses.
After cycle 10, group B blocks show a much smaller increase in mean permeability, and the range stays relatively steady — this may be explained by the capillary conditions set up by the smaller volume of the stone, allowing salts to migrate to the ‘back’ of the blocks and effectively relieving stress at the ‘front’ face.
Resumo:
The problem of the long-term impact of historical fire on masonry is not clearly understood. Much research focuses on the damage that is caused by fire in isolation, and omits to investigate the subsequent exploitation of weaknesses inherited from fire events. Fire can, for example, cause significant physical, chemical and mineralogical change to sandstone, which may then be exploited by background environmental factors such as salt and freeze–thaw weathering. To explore this experimentally, blocks of Peakmoor Sandstone were subjected to a real fire (as well as lime rendering/removal and frost cycle pre-treatments), and their subsequent response to salt weathering cycles was monitored by weight loss and visual assessment of the pattern of surface damage. Results illustrate that the post-fire deterioration of sandstone is strongly conditioned by fracture networks and soot cover inherited from the fire. The exploitation of fractures can lead to spalling during salt weathering cycles — this takes place as granular dissagregation steadily widens cracks and salts concentrate and crystallise in areas of inherited weakness. Soot cover can have a profound effect on subsequent performance. It reduces surface permeability and can be hydrophobic in character, limiting salt ingress and suppressing decay in the short term. However, as salt crystals concentrate under the soot crust, detachment of this layer can occur, exposing fire-damaged stone beneath. Understanding the subsequent exploitation of stone exposed to fire damage by background environmental factors (for example, salt weathering/ temperature cycling) is key to the post-fire management of stone decay.
Resumo:
This paper describes a substantial effort to build a real-time interactive multimodal dialogue system with a focus on emotional and non-verbal interaction capabilities. The work is motivated by the aim to provide technology with competences in perceiving and producing the emotional and non-verbal behaviours required to sustain a conversational dialogue. We present the Sensitive Artificial Listener (SAL) scenario as a setting which seems particularly suited for the study of emotional and non- verbal behaviour, since it requires only very limited verbal understanding on the part of the machine. This scenario allows us to concentrate on non-verbal capabilities without having to address at the same time the challenges of spoken language understanding, task modeling etc. We first report on three prototype versions of the SAL scenario, in which the behaviour of the Sensitive Artificial Listener characters was determined by a human operator. These prototypes served the purpose of verifying the effectiveness of the SAL scenario and allowed us to collect data required for building system components for analysing and synthesising the respective behaviours. We then describe the fully autonomous integrated real-time system we created, which combines incremental analysis of user behaviour, dialogue management, and synthesis of speaker and listener behaviour of a SAL character displayed as a virtual agent. We discuss principles that should underlie the evaluation of SAL-type systems. Since the system is designed for modularity and reuse, and since it is publicly available, the SAL system has potential as a joint research tool in the affective computing research community.
Resumo:
The government of the UK has set an ambitious target that all newly built homes be carbon neutral by 2016 and to achieving an overall 80% carbon emission by 2050. Carbon Trust in 2009 published a research revealing that non-domestic buildings accounted for 18% of the emissions in the UK. They argued that to achieve the targets of low carbon emission there is need for better building stock that are better used. The evaluation of the performance of buildings is therefore critical if the understanding of how they are used is to be known. This paper is a brief building performance evaluation of the newly build library at Queens University Belfast carried out during the summer of 2010. It employed the Post-Occupancy Evaluation (POE) methodology to assess its performance. The results reveal that despite the intelligent technologies in the building there was a mismatch between the measured data and the perception of users of its performance. The study suggests the need for further study for reasons of dichotomy of the data. Keywords: building performance evaluation, carbon reduction strategies, passive environmental design techniques, active renewable energy technologies, Northern Ireland