182 resultados para Vision Tests.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal permeability tests have been used to screen for a wide range of small intestinal diseases, including coeliac disease and enteric infections. Several probe molecules have been used to investigate intestinal permeability including monosaccharides, disaccharides, 51Cr-EDTA and polyethyleneglycol. While many factors may affect intestinal permeability tests, the use of two probe molecules, for example, lactulose and mannitol, and the expression of the result as a ratio minimises the effects of these extraneous factors. Rendering the test solution hyperosmolar was also found to increase the sensitivity of the test in detecting coeliac disease. Intestinal permeability is characteristically elevated in untreated coeliac disease, with a sensitivity of up to 96% for the dual sugar techniques. The reason for this is a consistent increase in the absorption of lactulose (via the paracellular route) due to increased "leakiness" of the intestine and a reduction in the absorption of mannitol (via the transcellular route) due to a reduction in surface area as a result of villous atrophy. The intestinal permeability test allows subjects to be selected for jejunal biopsy in whom the clinical features are compatible with coeliac disease and in timing a follow-up biopsy. It has been postulated that raised intestinal permeability may be involved in the pathogenesis of coeliac disease. Recently, serum measurements of the probe molecules may have a valuable role, particularly in paediatric patients. Sucrose permeability has also been proposed as an accurate marker of adult coeliac disease and shows promise as a noninvasive test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Routine intravenous cholangiography using the safer contrast medium, meglumine iotroxate, may be a useful investigation prior to laparoscopic cholecystectomy for the detection of suspected common bile duct stones. We compared this with endoscopic cholangiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we test the Prebish-Singer (PS) hypothesis, which states that real commodity prices decline in the long run, using two recent powerful panel data stationarity tests accounting for cross-sectional dependence and a structural break. We find that the hypothesis cannot be rejected for most commodities other than oil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Neurodevelopmental and behavioural problems have been repeatedly reported in very preterm. survivors, often showing themselves later in childhood as poor school performance. Early identification of problems would mean that appropriate remedial therapy can be implemented. We have previously shown that neurodevelopmental status at 1 year was predictive of outcome at 8 years in a cohort of preterm. infants. The aim of this paper was to see if neurodevelopmental outcome in adolescence could be predicted by assessment by 1 year in the same cohort of pretem infants. Study design: Prospective cohort study. Subjects: 150 adolescents, born before 33 weeks gestation. Outcome measures: Neurological examination, developmental quotient, vision and hearing by 1 year. At 14-15 years, neurological examination, school performance questionnaire, Schonnell test of reading age, a premorbid adjustment score, Rutter behavioural score and for those born from 1981, cognitive tests (WISC-R). Results: A highly significant relationship existed between neurological status by 1 year and the need for extra educational provision, overall neurodevelopmental status, cognitive function in those that had their IQs measured and premorbid adjustment score of prepsychotic symptoms in adolescence. However, status at 1 year was not predictive of adolescent reading age or behavioural score. Conclusions: Neurodevelopmental assessment at 1 year ispredictive of school performance and outcome in the adolescent period. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper seeks to explore the construction of narrative space in 3D PC computer games. With reference to Stephen Heath’s theory of filmic narrative space, the paper will examine how computer games, based on the rendition of a continuous 3D, real-time interactive environment, construct a distinct mode of narrativisation. The dynamic imbrication of the manipulation of 3D objects in a virtual world and the (re)presentation of this virtual mise-en-scene constitute an interaction that affects the concept of narrative in computer games. This leads to several questions that the paper seeks to investigate: How does the construction of space in PC games contribute to the meaning-making process or the gamer’s experience of narrative? How then is this experience of narrative game-space different from that of film?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow responsive passive samplers offer considerable potential in nutrient monitoring in catchments; bridging the gap between the intermittency of grab sampling and the high cost of automated monitoring systems. A commercially available passive sampler was evaluated in a number of river systems encapsulating a gradient in storm response, combinations of diffuse and point source pressures, and levels of phosphorus and nitrogen concentrations. Phosphorus and nitrogen are sequestered to a resin matrix in a permeable cartridge positioned in line with streamflow. A salt tracer dissolves in proportion to advective flow through the cartridge. Multiple deployments of different cartridge types were undertaken and the recovery of P and N compared with the flow-weighted mean concentration (FWMC) from high-resolution bank-side analysers at each site. Results from the passive samplers were variable and largely underestimated the FWMC derived from the bank-side analysers. Laboratory tests using ambient river samples indicated good replication of advective throughflow using pumped water, although this appeared not to be a good analogue of river conditions where flow divergence was possible. Laboratory tests also showed good nutrient retention but not elution and these issues appeared to combine to limit the utility in ambient river systems at the small catchment scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In astrophysical systems, radiation-matter interactions are important in transferring energy and momentum between the radiation field and the surrounding material. This coupling often makes it necessary to consider the role of radiation when modelling the dynamics of astrophysical fluids. During the last few years, there have been rapid developments in the use of Monte Carlo methods for numerical radiative transfer simulations. Here, we present an approach to radiation hydrodynamics that is based on coupling Monte Carlo radiative transfer techniques with finite-volume hydrodynamical methods in an operator-split manner. In particular, we adopt an indivisible packet formalism to discretize the radiation field into an ensemble of Monte Carlo packets and employ volume-based estimators to reconstruct the radiation field characteristics. In this paper the numerical tools of this method are presented and their accuracy is verified in a series of test calculations. Finally, as a practical example, we use our approach to study the influence of the radiation-matter coupling on the homologous expansion phase and the bolometric light curve of Type Ia supernova explosions. © 2012 The Authors Monthly Notices of the Royal Astronomical Society © 2012 RAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a novel approach for human action recognition based on the combination of computer vision techniques and common-sense knowledge and reasoning capabilities. The emphasis of this work is on how common sense has to be leveraged to a vision-based human action recognition so that nonsensical errors can be amended at the understanding stage. The proposed framework is to be deployed in a realistic environment in which humans behave rationally, that is, motivated by an aim or a reason. © 2012 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a step-wise approach for the understanding and interpretation of Humphrey's SITA visual field tests. The goal of this article is to help the reader to differentiate between non-specific abnormalities of the visual field and changes of the visual field that are suggestive of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to estimate costs and quality of life (QoL) of late-stage glaucoma patients in 4 European countries. Methods: Retrospective review of medical charts of patients with POAG who were followed in a low-vision or vision rehabilitation center in one of 4 countries for at least 1 year was used to determine patient characteristics, health status, and health care resource use. Visual impairment was measured by best-corrected visual acuity (Snellen score). Patients were also interviewed over the telephone in order to assess their health-related QoL (using EuroQol EQ-5D) and use of resources including: the number of visits to rehabilitation centers, visits to hospital and non-hospital specialists, the use of low-vision devices, medication, tests, and the use of hired home help. The costs associated with resource use were calculated from the perspective of a third-party payer of health and social care based on resource usage and unit costs in each country. Results: Patients undergoing visual rehabilitation in France (n=21), Denmark (n=59), Germany (n=60), and the United Kingdom (n=22) were identified, interviewed and had their medical charts reviewed. Annual maintenance costs of late-stage glaucoma amounted to €830 (±445) on average. Average home help costs were more than 3 times higher. QoL, on average, was 0.65 (±0.28). QoL was positively correlated with the level of visual acuity in the patients' best eye. On the other hand, visual acuity was also positively correlated to health care costs, but negatively correlated to costs of home help. Conclusions: The study was limited by its observational, uncontrolled design. The finding that late-stage glaucoma is associated with higher home help costs than health care maintenance costs suggests that potential savings from a better preventive treatment are to be found for social care payers rather than health care payers. © 2008 Informa UK Ltd All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.