148 resultados para Safety equipment.


Relevância:

20.00% 20.00%

Publicador:

Resumo:


OBJECTIVES: Precision Teaching (PT) has been shown to be an effective intervention to assess teaching method effectiveness and evaluate learning outcomes. SAFMEDS (Say All Fast Minute Every Day Shuffled) are a practice/assessment procedure within the PT framework to assist learning and fluency. We explored the effects of a brief intervention with PT, to impart high frequency performance in safe intravenous fluid prescription in a group of final year undergraduate medical students.
METHODS: 133 final year undergraduate medical students completed a multiple choice question (MCQ) test on safe IV fluid prescription at the beginning and end of the study. The control group (n= 76) of students were taught using a current standardized teaching method. Students allocated to the intervention arm of the study were additionally instructed on PT and the use of SAFMEDS. The study group (n = 57) received 50 SAFMEDS cards containing information on the principles of IV fluid prescription scenarios. These students were trained/tested twice per day for 1 minute.
RESULTS: Interim analysis showed that the study group displayed an improvement in fluency and accuracy as the study progressed. There was a statistically significant improvement in MCQ performance for the PT group compared with the control group between the beginning and end of the study (35% vs 15%).
CONCLUSION: These results suggest PT employing SAFMEDS is an effective method for improving fluency, accuracy and patient safety in intravenous fluid prescribing amongst undergraduate medical students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine if cognitive reflection has a positive influence on clinical decision making in undergraduate medical students. METHODS: 153 final year undergraduate medical students completed a 3 hour interactive Safe Thinking Workshop on nontechnical skills and patient safety, incorporating an introduction to metacognitive concepts. All students underwent augmented Cognitive Reflective Testing during the workshop. Students then inspected and interpreted a set of arterial blood gas results relating to a patient with acute respiratory distress, then answered a short questionnaire addressing biochemical diagnosis, clinical diagnosis and effective management. A separate question was embedded in the questionnaire to determine if astute students could determine the severity of the illness. The study group (n = 78) completed the questionnaire immediately after the Safe Thinking Workshop, whilst the control group (n = 75) completed the questionnaire prior to the Workshop.RESULTS: The mean total score for study students was 80.51%, with a mean total score of 57.9% for the control group (t-test; p<0.05). Correct classification of illness severity was observed in 13.2% of study students, compared with 4.1% of control students (p<0.05). CONCLUSION: These results suggest that clinical decision making and recognition of illness severity can be enhanced by specific teaching in nontechnical skills, metacognitiion and cognitive reflection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tomato is the second most widely grown vegetable crop across the globe and it is one of widely cultivated crops in Sri Lanka. However, tomato industry in Sri Lanka facing a problem of high postharvest loss (54%) during the glut coupled with heavy revenue loss to the country by importing processed products. The aim of this work is to develop shelf-stable tomato product with maximum quality characteristics using high pressure processing (HPP). Tomato juice with altered and unaltered pH was processed using HPP at 600 MPa for 1 min after blanching (90 oC/2 min). As a control tomato juice was subjected to thermal processing (TP) at 95 oC /20 min. Processed samples were stored under 20oC and 28oC for 9 month period and analysed for total viable count (TVC) and instrumental colour (L, a, b) value at 0,1,2 3, and 4 week and 2, 3, 6 and 9 months interval. The raw juice sample had initial 6.69 log10 CFU/ml and both TP and HPP caused a more than 4.69 log10 reduction in the TVC of juice and microbial numbers remained low throughout the storage period even at 3 months after storage irrespective of the storage temperature. Both TP and HPP treated samples had the redness ⤘a value’ of 14.44-17.15 just after processing and showed non-significant reduction with storage in all the treatments after 3 months. The storage study results and discussed in relation to the end goal and compared with the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulation of disorders of respiratory mechanics shown by spirometry provides insight into the pathophysiology of disease but some clinically important disorders have not been simulated and none have been formally evaluated for education. We have designed simple mechanical devices which, along with existing simulators, enable all the main dysfunctions which have diagnostic value in spirometry to be simulated and clearly explained with visual and haptic feedback. We modelled the airways as Starling resistors by a clearly visible mechanical action to simulate intra- and extra-thoracic obstruction. A narrow tube was used to simulate fixed large airway obstruction and inelastic bands to simulate restriction. We hypothesized that using simulators whose action explains disease promotes learning especially in higher domain educational objectives. The main features of obstruction and restriction were correctly simulated. Simulation of variable extra-thoracic obstruction caused blunting and plateauing of inspiratory flow, and simulation of intra-thoracic obstruction caused limitation of expiratory flow with marked dynamic compression. Multiple choice tests were created with questions allocated to lower (remember and understand) or higher cognitive domains (apply, analyse and evaluate). In a cross-over design, overall mean scores increased after 1½ h simulation spirometry (43-68 %, effect size 1.06, P < 0.0001). In higher cognitive domains the mean score was lower before and increased further than lower domains (Δ 30 vs 20 %, higher vs lower effect size 0.22, P < 0.05). In conclusion, the devices successfully simulate various patterns of obstruction and restriction. Using these devices medical students achieved marked enhancement of learning especially in higher cognitive domains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The novel long-acting β2-agonist olodaterol demonstrated an acceptable safety profile in short-term phase II clinical studies. This analysis of four randomized, double-blind, placebo-controlled, parallel-group, phase III studies (1222.11, NCT00782210; 1222.12, NCT00782509; 1222.13, NCT00793624; 1222.14, NCT00796653) evaluated the long-term safety of olodaterol once daily (QD) in a large cohort of patients with moderate to very severe (Global initiative for chronic Obstructive Lung Disease 2-4) chronic obstructive pulmonary disease (COPD). The studies compared olodaterol (5 or 10 μg) QD via Respimat®, formoterol 12 μg twice daily (BID) via Aerolizer® (1222.13 and 1222.14), and placebo for 48 weeks. Patients continued receiving background maintenance therapy, with ∼60% receiving concomitant cardiovascular therapy and 25% having a history of concomitant cardiac disease. Pre-specified analyses of pooled data assessed the adverse events (AEs) and serious AEs in the whole population, and in subgroups with cardiac disease, along with in-depth electrocardiogram and Holter monitoring. In total, 3104 patients were included in the safety analysis: 876 received olodaterol 5 μg, 883 received olodaterol 10 μg, 885 received placebos, and 460 received formoterol 12 μg BID. Overall incidence of on-treatment AEs (71.2%), serious AEs (16.1%), and deaths (1.7%) were balanced across treatment groups. Respiratory and cardiovascular AEs, including major adverse cardiac events, were reported at similar frequencies in placebo and active treatment groups. The safety profiles of both olodaterol 5 μg (marketed and registered dose) and 10 μg QD delivered via Respimat® are comparable to placebo and formoterol BID in this population, with no safety signals identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pesticide use is important in agriculture to protect crops and improve productivity. However, they have the potential to cause adverse human health or environmental effects, dependent on exposure levels. This review examines existing pesticide legislation worldwide, focusing on the level of harmonisation, and impacts of differing legislation on food safety and trade. Pesticide legislation varies greatly worldwide as countries have different requirements guidelines and legal limits for plant protection. Developed nations have more stringent regulations than developing countries, which lack the resources and expertise to adequately implement and enforce legislation. Global differences in pesticide legislation act as a technical barrier to trade. International parties such as the European Union (EU), Codex Alimentarius Commission (Codex), and North American Free Trade Agreement (NAFTA) have attempted to harmonise pesticide legislation by providing maximum residue limits (MRLs), but globally these limits remain variable. Globally harmonised pesticide standards would serve to increase productivity, profits and trade, and enhance the ability to protect public health and the environment. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Issues surrounding the misuse of prohibited and licensed substances in animals destined for food production and performance sport competition continue to be an enormous challenge to regulatory authorities charged with enforcing their control. Efficient analytical strategies are implemented to screen and confirm the presence of a wide range of exogenous substances in various biological matrices. However, such methods rely on the direct measurement of drugs and/or their metabolites in a targeted mode, allowing the detection of restricted number of compounds. As a consequence, emerging practices, in particular the use of natural hormones, designer drugs and low-dose cocktails, remain difficult to handle from a control point of view. A new SME-led FP7 funded project, DeTECH21, aims to overcome current limitations by applying an untargeted metabolomics approach based on liquid chromatography coupled to high resolution mass spectrometry and bioinformatic data analysis to identify bovine and equine animals which have been exposed to exogenous substances and assist in the identification of administered compounds. Markerbased strategies, dealing with the comprehensive analysis of metabolites present in a biological sample (urine/plasma/tissue), offer a reliable solution in the areas of food safety and animal sport doping control by effective, high-throughput and sensitive detection of exogenously administered agents. Therefore, the development of the first commercially available forensic test service based on metabolomics profiling will meet 21st century demands in animal forensics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With interest in microneedles as a novel drug transdermal delivery system increasing rapidly since the late 1990s (Margetts and Sawyer Contin Educ Anaesthesia Crit Care Pain. 7(5):171-76, 2007), a diverse range of microneedle systems have been fabricated with varying designs and dimensions. However, there are still very few commercially available microneedle products. One major issue regarding microneedle manufacture on an industrial scale is the lack of specific quality standards for this novel dosage form in the context of Good Manufacturing Practice (GMP). A range of mechanical characterisation tests and microneedle insertion analysis techniques are used by researchers working on microneedle systems to assess the safety and performance profiles of their various designs. The lack of standardised tests and equipment used to demonstrate microneedle mechanical properties and insertion capability makes it difficult to directly compare the in use performance of candidate systems. This review highlights the mechanical tests and insertion analytical techniques used by various groups to characterise microneedles. This in turn exposes the urgent need for consistency across the range of microneedle systems in order to promote innovation and the successful commercialisation of microneedle products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research based upon microneedle (MN) arrays has intensified recently. While the initial focus was on biomolecules, the field has expanded to include delivery of conventional small-molecule drugs whose water solubility currently precludes transdermal administration. Much success has been achieved, with peptides, proteins, vaccines, antibodies and even particulates delivered by MN in therapeutic/prophylactic doses. Recent innovations have focused on enhanced formulation design, scalable manufacture and extension of exploitation to minimally invasive patient monitoring, ocular delivery and enhanced administration of cosmeceuticals. Only two MN-based drug/vaccine delivery products are currently marketed, partially due to limitations with older MN designs based upon silicon and metal. Even the more promising polymeric MN have raised a number of regulatory and manufacturability queries that the field must address. MN arrays have tremendous potential to yield real benefits for patients and industry and, through diligence, innovation and collaboration, this will begin to be realised over the next 3-5 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this case, an individual was suspected of attempting to burn materials potentially relating to a murder case. A number of spent and unspent matches were seized at the scene by police for forensic examination. Coincidentally, a police raid at the suspect's house revealed a number of matchboxes, all of the same brand, containing matches that had a visual similarity to those recovered at the scene. Stable Isotope Profiling (SIP) was used to assess whether matches could either be distinguished or shown to be indistinguishable by 13C and 2H isotopic composition. These results were then compared to those from the X-ray diffraction (XRD) analysis of match heads and microscopy of the wood. SIP showed the scene matches and seized matches to be different, which was confirmed by XRD and microscopy analyses.