166 resultados para Plastic surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). Design: Nonconsecutive observational case series. Participants and Intervention: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. Main Outcome Measures: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. Results: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5 ± 12 mmHg, and after surgery 11.8 ± 5.2 mmHg (mean follow-up, 26 ± 7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P <0.005). The age of the patient correlated highly with change in maximum cup depth (P <0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). Conclusion: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PurposeThe World Health Organisation (WHO) identified patient safety in surgery as an important public health matter and advised the adoption of a universal peri-operative surgical checklist. An adapted version of the WHO checklist has been mandatory in the National Health Service since 2010. Wrong intraocular lens (IOL) implantation is a particular safety concern in ophthalmology. The Royal College of Ophthalmologists launched a bespoke checklist for cataract surgery in 2010 to reduce the likelihood of preventable errors. We sought to ascertain the use of checklists in cataract surgery in 2012.Patients and methodsA survey of members of the Royal College of Ophthalmologists seeking views on the use of checklists in cataract surgery. Four hundred and sixty-nine completed responses were received (18% response rate).ResultsRespondents worked in England (75%), Scotland (11%), Wales (5%), Northern Ireland (2%), the Republic of Ireland (1%), and overseas (6%). Ninety-four per cent of respondents support the use of a checklist for cataract surgery and 85% say that they always use a checklist before cataract surgery. Sixty-seven per cent of cataract surgeons stated they undertake a pre-operative team brief. Thirty-six per cent use a cataract surgery checklist developed locally, 18% use the college's bespoke cataract surgery checklist, 39% use a generic surgical checklist, and 4% reported that they do not use a checklist.ConclusionNinety-three per cent of cataract surgeons responding to the questionnaire report using a surgical checklist and 67% use a team brief. However, only 54% use a checklist, which addresses the selection of the correct intraocular implant. We recommend wider adoption of checklists, which address risks relevant to cataract surgery, in particular the possibility of selection of an incorrect IOL.Eye advance online publication, 24 May 2013; doi:10.1038/eye.2013.101.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. ?Methods: The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. ?Results: A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (?2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). ?Conclusion: Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plastic wastes, and particularly plastic bags and sachets, are a major concern for urban and rural environment in African countries. In the last years some actions have been started for the plastic recycling like the artisanal production of paving blocks with melted plastic bags and sand, albeit with differences in production processes. Nevertheless, the environmental and economic impact of such activities is still to be confirmed. The aim of this study is to propose a methodology for assessing and comparing the environmental and energetic performances of artisanal methods, and for defining the overall quality of the produced blocks. This methodology has been shaped through the analysis of
production processes operated by artisans/small enterprises in West Africa and through physic-mechanical tests on the blocks. A questionnaire which allows an insight into the process and on the product has been developed and tested over five processes. Results show that a high input energy level is observed through all the processes, while considerable savings of energy could be achieved. Moreover, tests results confirmed the importance of the utilised plastic concerning thermal dilatation, mechanical resistance at higher temperature and cooling-shrinkage effects. In conclusion, doubts remain about the technical and environmental effectiveness of the sampled experiences, durability of the products and sustainability of this approach. Nevertheless, being the collection and recycling of plastic wastes a potential income generation activity for marginalised social groups in urban environment, a process optimisation could improve the impact of blocks production. Alternative recycling activities should also be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paired adrenal (suprarenal) glands are flattened retroperitoneal endocrine glands closely applied to the medial aspect of the superior pole of each kidney. The internal structure of these pale yellow glands are incongruous in that the adrenal gland is composed of two discrete parts, namely an outer cortex enveloping a central medulla. The adrenal cortex and medulla contain distinct endocrine tissues that secrete different hormones and are regulated by separate control systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of constitutive models that account for creep or secondary compression and rate dependent behaviour of soil have been reviewed in terms of their strengths and weaknesses. Some results of numerical analysis of some embankments have been discussed and an effort has been made to find out their strengths and limitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery.

METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed.

RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was
39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point.

CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the
mediastinum should be undertaken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to investigate drilling process in carbon-fiber reinforced plastic (CFRP) composites with multilayer TiAlN/TiN PVD-coated tungsten carbide drill. The effect of process parameters have been investigated in drilling of Hexcel M21-T700GC. Thrust force and torque were measured online throughout the drilling experiments. Delamination were observed using optical microscope and analyzed via a developed algorithm based on digital image processing technique. Surface roughness of each hole was measured using a surface profilometer. In addition, the progression of tool wear in various surfaces of drill was observed using tool microscope and measured using image software. Our results indicate that the thrust force and torque increased with the increasing cutting speed and feed rate. Delamination and average surface roughness that rose with the increase in feed rate, however, decreased with the increasing cutting speed. The average surface roughness tended to increase with the increase in feed rate and decrease with the increasing cutting speed in drilling of carbon-fiber reinforced plastic (CFRP). Feed rate was found as the predominant factor on the drilling outputs. Abrasive wear was observed on both flank and relief surfaces, which created edge wear on cutting edges. No sign of chipping or plastic deformation has been observed on the surfaces of drills. © 2012 The Author(s).