118 resultados para Operating costs.
High-Efficiency Harmonic-Peaking Class-EF Power Amplifiers with Enhanced Maximum Operating Frequency
Resumo:
The recently introduced Class-EF power amplifier (PA) has a peak switch voltage lower than that of the Class-E PA. However, the value of the transistor output capacitance at high frequencies is typically larger than the required Class-EF optimum shunt capacitance. Consequently, soft-switching operation that minimizes power dissipation during off-to-on transition cannot be achieved at high frequencies. Two new Class-EF PA variants with transmission-line load networks, namely, third-harmonic-peaking (THP) and fifth-harmonic-peaking (FHP) Class-EF PAs are proposed in this paper. These permit operation at higher frequencies at no expense to other PA figures of merit. Analytical expressions are derived in order to obtain circuit component values, which satisfy the required Class-EF impedances at fundamental frequency, all even harmonics, and the first few odd harmonics as well as simultaneously providing impedance matching to a 50- Ω load. Furthermore, a novel open-circuit and shorted stub arrangement, which has substantial practical benefits, is proposed to replace the normal quarter-wave line connected at the transistor's drain. Using GaN HEMTs, two PA prototypes were built. Measured peak drain efficiency of 91% and output power of 39.5 dBm were obtained at 2.22 GHz for the THP Class-EF PA. The FHP Class-EF PA delivered output power of 41.9 dBm with 85% drain efficiency at 1.52 GHz.
Resumo:
BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.
OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.
DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).
REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.
INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).
COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.
RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.
LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.
CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.
STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.
FUNDING: The National Institute for Health Research Health Technology Assessment programme.
Resumo:
Photovoltaic (PV) solar power generation is proven to be effective and sustainable but is currently hampered by relatively high costs and low conversion efficiency. This paper addresses both issues by presenting a low-cost and efficient temperature distribution analysis for identifying PV module mismatch faults by thermography. Mismatch faults reduce the power output and cause potential damage to PV cells. This paper first defines three fault categories in terms of fault levels, which lead to different terminal characteristics of the PV modules. The investigation of three faults is also conducted analytically and experimentally, and maintenance suggestions are also provided for different fault types. The proposed methodology is developed to combine the electrical and thermal characteristics of PV cells subjected to different fault mechanisms through simulation and experimental tests. Furthermore, the fault diagnosis method can be incorporated into the maximum power point tracking schemes to shift the operating point of the PV string. The developed technology has improved over the existing ones in locating the faulty cell by a thermal camera, providing a remedial measure, and maximizing the power output under faulty conditions.
Resumo:
BACKGROUND: The number of patients with advanced chronic kidney disease opting for conservative management rather than dialysis is unknown but likely to be growing as increasingly frail patients with advanced renal disease present to renal services. Conservative kidney management includes ongoing medical input and support from a multidisciplinary team. There is limited evidence concerning patient and carer experience of this choice. This study will explore quality of life, symptoms, cognition, frailty, performance decision making, costs and impact on carers in people with advanced chronic kidney disease managed without dialysis and is funded by the National Institute of Health Research in the UK.
METHODS: In this prospective, multicentre, longitudinal study, patients will be recruited in the UK, by renal research nurses, once they have made the decision not to embark on dialysis. Carers will be asked to 'opt-in' with consent from patients. The approach includes longitudinal quantitative surveys of quality of life, symptoms, decision making and costs for patients and quality of life and costs for carers, with questionnaires administered quarterly over 12 months. Additionally, the decision making process will be explored via qualitative interviews with renal physicians/clinical nurse specialists.
DISCUSSION: The study is designed to capture patient and carer profiles when conservative kidney management is implemented, and understand trajectories of care-receiving and care-giving with the aim of optimising palliative care for this population. It will explore the interactions that lead to clinical care decisions and the impact of these decisions on informal carers with the intention of improving clinical outcomes for patients and the experiences of care givers.
Resumo:
This study proposes an approach to optimally allocate multiple types of flexible AC transmission system (FACTS) devices in market-based power systems with wind generation. The main objective is to maximise profit by minimising device investment cost, and the system's operating cost considering both normal conditions and possible contingencies. The proposed method accurately evaluates the long-term costs and benefits gained by FACTS devices (FDs) installation to solve a large-scale optimisation problem. The objective implies maximising social welfare as well as minimising compensations paid for generation re-scheduling and load shedding. Many technical operation constraints and uncertainties are included in problem formulation. The overall problem is solved using both particle swarm optimisations for attaining optimal FDs allocation as main problem and optimal power flow as sub-optimisation problem. The effectiveness of the proposed approach is demonstrated on modified IEEE 14-bus test system and IEEE 118-bus test system.
Resumo:
A double layer circular polarization (CP) frequency selective surface (FSS) for use as a dual-band quasi-optical diplexer suitable for deployment in reflector antenna systems is described. The FSS was designed to reflect Ku band signals (11.7–12.75 GHz) while transmitting Ka band signals (17.3–20.2 GHz) and conserving CP in each of these bands. The simulated/measured reflection loss over the Ku band was less than 0.05/0.1 dB for both TE and TM polarizations, while the simulated/measured axial ratio was less than 0.2/0.75 dB. Over the Ka band, the simulated/measured transmission loss for both polarizations was below 0.25/0.4 dB and the simulated/measured axial ratio was less than 0.25/0.75 dB. To the best of our knowledge, this is the first report of a metallo-dielectric FSS that simultaneously operates in CP for an oblique angle of incidence in both Ku and Ka bands.
Resumo:
Objectives The increasing prevalence of overweight and obesity worldwide continues to compromise population health and creates a wider societal cost in terms of productivity loss and premature mortality. Despite extensive international literature on the cost of overweight and obesity, findings are inconsistent between Europe and the USA, and particularly within Europe. Studies vary on issues of focus, specific costs and methods. This study aims to estimate the healthcare and productivity costs of overweight and obesity for the island of Ireland in 2009, using both top-down and bottom-up approaches.
Methods Costs were estimated across four categories: healthcare utilisation, drug costs, work absenteeism and premature mortality. Healthcare costs were estimated using Population Attributable Fractions (PAFs). PAFs were applied to national cost data for hospital care and drug prescribing. PAFs were also applied to social welfare and national mortality data to estimate productivity costs due to absenteeism and premature mortality.
Results The healthcare costs of overweight and obesity in 2009 were estimated at €437 million for the Republic of Ireland (ROI) and €127.41 million for NI. Productivity loss due to overweight and obesity was up to €865 million for ROI and €362 million for NI. The main drivers of healthcare costs are cardiovascular disease, type II diabetes, colon cancer, stroke and gallbladder disease. In terms of absenteeism, low back pain is the main driver in both jurisdictions, and for productivity loss due to premature mortality the primary driver of cost is coronary heart disease.
Conclusions The costs are substantial, and urgent public health action is required in Ireland to address the problem of increasing prevalence of overweight and obesity, which if left unchecked will lead to unsustainable cost escalation within the health service and unacceptable societal costs.
Resumo:
In the 19th century, firms operating in the Anglo-Indian tea trade were organised using a variety ownership forms including the partnership, joint-stock and a combination of the two known as the Managing agency. Faced with both an increasing need for fixed capital and high agency costs caused by the distance between owners and managers, the firms adapted and increasingly adopted the hybrid managing agency model to overcome these problems. Using new data from Calcutta and Bengal Commercial Registers and detailed case studies of the Assam Company and Gillanders, Arbuthnot and Co, this paper demonstrates that British entrepreneurs did not see the choice of ownership as a dichotomy or firm boundaries as fixed, but instead innovatively drew on the strengths of different forms of ownership to compete and grow successfully.
Resumo:
Channel randomness can be exploited to generate secret keys. However, to ensure secrecy, it is necessary that the channel response of any eavesdropping party remain sufficiently de-correlated with that of the legitimate users'. In this paper, we investigate whether such de-correlation occurs for a body area network (BAN) operating in an indoor environment at 2.45 GHz. The hypothetical BAN configuration consisted of two legitimate transceivers, one situated on the user's left wrist and the other on the user's waist. The eavesdroppers were positioned in either a co-located or distributed manner in the area surrounding the BAN user. Using the simultaneous channel response measured at the legitimate BAN nodes and the eavesdropper positions for stationary and mobile scenarios, we analyze the localized correlation coefficient. This allows us to determine if it is possible to generate secret keys in the presence of multiple eavesdroppers in an indoor environment. Our experimental results show that although channel reciprocity was observed for both the stationary and the mobile scenarios, a higher de-correlation between the legitimate users' channels was observed for the stationary case. This indicates that mobile scenarios are better suited for secret key generation.
Resumo:
Models of ground source heat pump (GSHP) systems are used as an aid for the correct design and optimization of the system. For this purpose, it is necessary to develop models which correctly reproduce the dynamic thermal behavior of each component in a short-term basis. Since the borehole heat exchanger (BHE) is one of the main components, special attention should be paid to ensuring a good accuracy on the prediction of the short-term response of the boreholes. The BHE models found in literature which are suitable for short-term simulations usually present high computational costs. In this work, a novel TRNSYS type implementing a borehole-to-ground (B2G) model, developed for modeling the short-term dynamic performance of a BHE with low computational cost, is presented. The model has been validated against experimental data from a GSHP system located at Universitat Politècnica de València, Spain. Validation results show the ability of the model to reproduce the short-term behavior of the borehole, both for a step-test and under normal operating conditions.