287 resultados para Medical Implants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contamination of medical devices with bacteria such as Meticillin resistant Staphylococcus aureus (MRSA) is of great clinical concern. Poly(vinyl chloride) is widely used in the production of medical devices, such as catheters. The flexibility of catheter tubing is derived from the addition of plasticisers. Here, we report the design of two dual functional ionic liquids, 1-ethylpyridinium docusate and tributyl(2-hydroxyethyl)phosphonium docusate, which uniquely provide a plasticising effect, and exhibit antimicrobial and antibiofilm-forming activity to a range of antibiotic resistant bacteria. The plasticisation of poly(vinyl chloride) was tailored as a function of ionic liquid concentration. The effective antimicrobial behaviour of both ionic liquids originates from the chemical structure of the anion or cation and is not limited to the length of the alkyl chain on the anion/cation. The design approach adopted will be useful in developing ionic liquids as multi-functional additives for polymers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives This student selected component (SSC) was designed to equip United Kingdom (UK) medical students to respond ethically and with sensitivity to requests they might receive as qualified doctors in regard to euthanasia and assisted dying. The aim was to expose students to relevant opinions and experiences and to provide opportunities to explore and justify their own views and rehearse ethical decision making in a safe learning environment. Method The module is delivered by specialists from a number of disciplines including law, theology, medicine and nursing, each providing students with a working knowledge allowing them to actively discuss cases, articulate their own views and practise ethical reasoning through group and individual study. Visits to local intensive care units, palliative care wards and hospices are integrated effectively with theory. Student assessment comprises a dissertation, student-led debate and reflective commentary. Module impact was evaluated by analysis of student coursework and a questionnaire. Results Students found the content stimulating and relevant to their future career and agreed that the module was well-structured and that learning outcomes were achieved. They greatly appreciated the clinical context provided by the visits and opportunities to apply ethical reasoning to real cases and to debate ethical issues with peers. Students reported an increased discernment of the ethical and legal position and practical considerations and a greater awareness of the range of professional and lay viewpoints held. Student perceptions were confirmed on analysis of their submitted coursework. Many participants were less strongly in favour of euthanasia and assisted dying on module completion than at the outset but all felt better equipped to justify their own viewpoint and to respond appropriately to patient requests. Conclusions The multi-disciplinary nature of this course is helpful in preparing students to deal effectively and sensitively with ethical dilemmas they will encounter in their medical career. Use of an integrated, learner-centred approach equips students to actively engage with their peers in discussion of such issues and to formulate and defend their own position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate factors that influence hospital readmissions of elderly patients and to construct a robust hospital readmissions predictive model.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.

Relevância:

20.00% 20.00%

Publicador: