140 resultados para Hyperspectral imaging,


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall aim of this study was to assess the accuracy, reproducibility and stability of a high resolution passive stereophotogrammetry system to image a female mannequin torso, to validate measurements made on the textured virtual surface compared with those obtained using manual techniques and to develop an approach to make objective measurements of the female breast. 3D surface imaging was carried out on a textured female torso and measurements made in accordance with the system of mammometrics. Linear errors in measurements were less than 0.5 mm, system calibration produced errors of less than 1.0 mm over 94% over the surface and intra-rater reliability measured by ICC = 0.999. The mean difference between manual and digital curved surface distances was 1.36 mm with maximum and minimum differences of 3.15 mm and 0.02 mm, respectively. The stereophotogrammetry system has been demonstrated to perform accurately and reliably with specific reference to breast assessment. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work is an evaluation of quantitative measurements of piezoresponse force microscopy for nanoscale characterization of ferroelectric films. To this end, we investigate how the piezoresponse phase difference Delta Phi between c domains depends on the frequency omega of the applied ac field much lower than the cantilever first resonance frequency. The main specimen under study was a 102 nm thick film of Pb(Zr(0.2)Ti(0.8))O(3). For the sake of comparison, a 100 nm thick PbTiO(3) film was also used. From our measurements, we conclude a frequency dependent behavior Delta Phi similar to omega(-1), which can only be partially explained by the presence of adsorbates on the surface. (C) 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural and functional change in the microcirculation in type 1 diabetes mellitus predicts future end-organ damage and macrovascular events. We explored the utility of novel signal processing techniques to detect and track change in ocular hemodynamics in patients with this disease. 24 patients with uncomplicated type 1 diabetes mellitus, and 18 age-and-sex matched control subjects were studied. Doppler ultrasound was used to interrogate the carotid and ophthalmic arteries and digital photography to image the retinal vasculature. Frequency analysis algorithms were applied to quantify velocity waveform structure and retinal photographic data at baseline and following inhalation of 100% oxygen. Frequency data was compared between groups. No significant differences were found in the resistive index between groups at baseline or following inhaled oxygen. Frequency analysis of the Doppler flow velocity waveforms identified significant differences in bands 3-7 between patients and controls in data captured from the ophthalmic artery (p<0.01 for each band). In response to inhaled oxygen, changes in the frequency band amplitudes were significantly greater in control subjects compared with patients (p<0.05). Only control subjects demonstrated a positive correlation (R=0.61) between change in retinal vessel diameter and frequency band amplitudes derived from ophthalmic artery waveform data. The use of multimodal signal processing techniques applied to Doppler flow velocity waveforms and retinal photographic data identified preclinical change in the ocular microcirculation in patients with uncomplicated diabetes mellitus. An impaired autoregulatory response of the retinal microvasculature may contribute to the future development of retinopathy in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production of shock- and collimated jet-like features is recorded from the self-emission of a plasma using a 16- frame camera, which can show the progression of the interaction over short (100s ns) durations. A cluster of laser beams, with intensity 1015 W/cm2, was focused onto a planar aluminum foil to produce a plasma that expanded into 0.7 mbar of argon gas. The acquisition of 16 ultrafast images on a single shot allows prompt spatial and temporal characterization of the plasma and enables the velocity of the jet- and shock-like features to be calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectroscopic capability of the photon scanning tunneling microscope is exploited to study directly the launch and propagation of surface plasmons on thin silver films. Two input beams, of different wavelength, are incident through the prism in a prism-Ag film-air-fibre tip system. Both excite surface plasmons at the Ag-air interface and light of both wavelengths is coupled into the fibre probe via the respective surface plasmon evanescent fields. One laser beam is used for instrument control. The second, or probe beam is tightly focused on the sample, within the area of the unfocused or control beam, giving a well-defined and symmetrical, confined surface plasmon launch site. However, the image at the probe wavelength is highly asymmetrical in section with an exponential tail extending beyond one side of the launch site. This demonstrates in a very direct fashion;the propagation of surface plasmons; a propagation length of similar to 11.7 mu m is measured at a probe wavelength of 543.5 nm. On rough Ag films the excitation of localised scattering centres is also observed in addition to the launch of delocalised surface plasmons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution imaging of a dipole source in stratified medium based on negative refraction is presented in this paper. Compensation of the material parameter contrast at the stratified media interface is achieved using a gradient phase profiled conjugating lens (GPCL). It is shown both analytically and numerically that the phase gradient applied across the GPCL positioned at the interface of vertically stratified media enables a high-quality image of a dipole source in a mirror symmetric position with respect to the lens plane. The analytical closed form expression of the phase gradient function is derived using Huygens-Kirchhoff principle. The result is applicable to media with arbitrary stratification and material parameters, including lossy materials. The mechanism for formation of the dipole image in the stratified medium and aberration due to the dielectric contrast at the interface, particularly electromagnetic loss, is discussed in detail. The efficacy of gradient phase and amplitude aberration compensations mechanisms available through the GPCL is articulated. The results of the study are of importance in a wide range of imaging problems in stratified media for medical, civil, and military applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanoparticles offer alternative options in cancer therapy both as drug delivery carriers and as direct therapeutic agents for cancer cell inactivation. More recently, gold nanoparticles (AuNPs) have emerged as promising radiosensitizers achieving significantly elevated radiation dose enhancement factors when irradiated with both kilo-electron-volt and mega-electronvolt X-rays. Use of AuNPs in radiobiology is now being intensely driven by the desire to achieve precise energy deposition in tumours. As a consequence, there is a growing demand for efficient and simple techniques for detection, imaging and characterization of AuNPs in both biological and tumour samples. Spatially accurate imaging on the nanoscale poses a serious challenge requiring high- or super-resolution imaging techniques. In this mini review, we discuss the challenges in using AuNPs as radiosensitizers as well as various current and novel imaging techniques designed to validate the uptake, distribution and localization in mammalian cells. In our own work, we have used multiphoton excited plasmon resonance imaging to map the AuNP intracellular distribution. The benefits and limitations of this approach will also be discussed in some detail. In some cases, the same "excitation" mechanism as is used in an imaging modality can be harnessed tomake it also a part of therapymodality (e.g. phototherapy)-such examples are discussed in passing as extensions to the imaging modality concerned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the labile status of phosphorus (P) in sediments is crucial for managing a eutrophic lake, but it is hindered by lacking in situ data particularly on a catchment scale. In this study, we for the first time characterized in situ labile P in sediments with the Zr-oxide diffusive gradients in thin films (Zr-oxide DGT) technique at a two-dimensional (2D), submillimeter resolution in a large eutrophic lake (Lake Taihu, China, with an area of 2338km2). The concentration of DGT-labile P in the sediment profiles showed strong variation mostly ranging from 0.01 to 0.35mgL-1 with a considerable number of hotspots. The horizontal heterogeneity index of labile P varied from 0.04 to 4.5. High values appeared at the depths of 0-30mm, likely reflecting an active layer of labile P under the sediment-water interface (SWI). Concentration gradients of labile P were observed from the high-resolution 1D DGT profiles in both the sediment and overlying water layers close to the SWI. The apparent diffusion flux of P across the SWI was calculated between -21 and 65ngcm-2d-1, which showed that the sediments tended to be a source and sink of overlying water P in the algal- and macrophyte-dominated regions, respectively. The DGT-labile P in the 0-30mm active layer showed a better correlation with overlying water P than the labile P measured by ex situ chemical extraction methods. It implies that in situ, high-resolution profiling of labile P with DGT is a more reliable approach and will significantly extend our ability in in situ monitoring of the labile status of P in sediments in the field.