114 resultados para Ear Protective Devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study explored the effect of HPP (400 MPa/1 min) and a Weissella viridescens protective culture, alone or in conjunction, against Listeria monocytogenes in ready-to-eat (RTE) salads with different pH values (4.32 and 5.59) during storage at 4 and 12 °C. HPP was able to reduce the counts of the pathogen after treatment achieving approximately a 4.0 and 1.5 log CFU/g reduction in the low and higher pH RTE salad, respectively. However, L. monocytogenes was able to recover and grow during subsequent storage. W. viridescens grew in both RTE salads at both storage temperatures, with HPP resulting in only a small immediate reduction of W. viridescens ranging from 0.50 to 1.2 log CFU/g depending on the pH of the RTE salad. For the lower pH RTE salad, the protective culture was able to gradually reduce the L. monocytogenes counts during storage whereas for the higher pH RTE salad in some cases it delayed growth significantly or exerted a bacteriostatic effect. exerted a bacteriostatic effect. The results revealed that the increased storage temperature led to an increase in the inactivation/inhibition of L. monocytogenes in the presence of W. viridescens. The combination of HPP and W. viridescens is a promising strategy to control L. monocytogenes and can increase safety even when a break in the chill chain occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperament tests are widely accepted as instruments for profiling behavioral variability in dogs, and they are applied in numerous areas of investigation (e.g. suitability for adoption or for breeding). During testing, to elicit a dog's reaction toward novel stimuli and predict its behavior in everyday life, model devices such as a child-like doll, or a fake dog, are often employed. However, the reliability of these devices to accurately stimulate dogs' reactions to children or dogs, is unknown and perhaps overestimated. This may be a particular concern in the case of aggressive behavior toward humans, a significant public health issue. The aim of this study was to: (1) evaluate the correlation between dogs' reactions to these devices, and owners' reports of their dog's aggression history (using the C-BARQ ??); (2) compare reactions toward the devices of dogs with and without histories of aggression. Subjects were selected among those visiting for behavioral consultation at the Veterinary Hospital of the University of Pennsylvania, and previously categorized as aggressive toward unfamiliar children, conspecifics, or as non-aggressive dogs (control). The test consisted of different components: an unfamiliar female tester approaching the dog; the presentation of a child-like doll, an ambiguous object, and a fake plastic dog. All tests were videotaped and durations of behaviors were later analyzed on the basis of a specified ethogram. Dogs' reactions were compared to C-BARQ scores, and interesting correlations emerged for 'dog-directed aggression/fear' (R = 0.48, P = 0.004), and 'stranger-directed aggression' (R = 0.58, P <0.001) factors. Dogs differed in their reactions toward the devices: the child-like doll and the fake dog elicited more social behaviors than the ambiguous object used as a control stimulus. Issues concerning the reliability of these tools to assess canine temperament are discussed. ?? 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The idea of proxying network connectivity has been proposed as an efficient mechanism to maintain network presence on behalf of idle devices, so that they can “sleep”. The concept has been around for many years; alternative architectural solutions have been proposed to implement it, which lead to different considerations about capability, effectiveness and energy efficiency. However, there is neither a clear understanding of the potential for energy saving nor a detailed performance comparison among the different proxy architectures. In this paper, we estimate the potential energy saving achievable by different architectural solutions for proxying network connectivity. Our work considers the trade-off between the saving achievable by putting idle devices to sleep and the additional power consumption to run the proxy. Our analysis encompasses a broad range of alternatives, taking into consideration both implementations already available in the market and prototypes built for research purposes. We remark that the main value of our work is the estimation under realistic conditions, taking into consideration power measurements, usage profiles and proxying capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glucagon-like peptide-1 (GLP-1) therapies are routinely used for glycaemic control in diabetes and their emerging cardiovascular actions have been a major recent research focus. In addition to GLP-1 receptor activation, the metabolically-inactive breakdown product, GLP-1(9-36)amide, also appears to exert notable cardiovascular effects, including protection against acute cardiac ischaemia. Here, we specifically studied the influence of GLP-1(9-36)amide on chronic post-myocardial infarction (MI) remodelling, which is a major driver of heart failure progression.

METHODS: Adult female C57BL/6 J mice were subjected to permanent coronary artery ligation or sham surgery prior to continuous infusion with GLP-1(9-36)amide or vehicle control for 4 weeks.

RESULTS: Infarct size was similar between groups with no effect of GLP-1(9-36)amide on MI-induced cardiac hypertrophy, although modest reduction of in vitro phenylephrine-induced H9c2 cardiomyoblast hypertrophy was observed. Whilst echocardiographic systolic dysfunction post-MI remained unchanged, diastolic dysfunction (decreased mitral valve E/A ratio, increased E wave deceleration rate) was improved by GLP-1(9-36)amide treatment. This was associated with modulation of genes related to extracellular matrix turnover (MMP-2, MMP-9, TIMP-2), although interstitial fibrosis and pro-fibrotic gene expression were unaltered by GLP-1(9-36)amide. Cardiac macrophage infiltration was also reduced by GLP-1(9-36)amide together with pro-inflammatory cytokine expression (IL-1β, IL-6, MCP-1), whilst in vitro studies using RAW264.7 macrophages revealed global potentiation of basal pro-inflammatory and tissue protective cytokines (e.g. IL-1β, TNF-α, IL-10, Fizz1) in the presence of GLP-1(9-36)amide versus exendin-4.

CONCLUSIONS: These data suggest that GLP-1(9-36)amide confers selective protection against post-MI remodelling via preferential preservation of diastolic function, most likely due to modulation of infiltrating macrophages, indicating that this often overlooked GLP-1 breakdown product may exert significant actions in this setting which should be considered in the context of GLP-1 therapy in patients with cardiovascular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The TELL ME agent based model simulates the connections between health agency communication, personal decisions to adopt protective behaviour during an influenza epidemic, and the effect of those decisions on epidemic progress. The behaviour decisions are modelled with a combination of personal attitude, behaviour adoption by neighbours, and the local recent incidence of influenza. This paper sets out and justifies the model design, including how these decision factors have been operationalised. By exploring the effects of different communication strategies, the model is intended to assist health authorities with their influenza epidemic communication plans. It can both assist users to understand the complex interactions between communication, personal behaviour and epidemic progress, and guide future data collection to improve communication planning.