229 resultados para Conventional products
Resumo:
A mechanistic study of the H-2-assisted Selective Catalytic Reduction (SCR) of NOx with octane as reductant over a Ag/Al2O3 catalyst was carried out using a modified DRIFTS cell coupled to a mass spectrometer Using fast transient cycling switching of H-2 with a time resolution of a few seconds It was possible to differentiate potential reaction intermediates from other moieties that are clearly spectator species Using such a periodic operation mode effects were uncovered that are normally hidden in conventional transient studies which typically consist of a single transient In experiments based on a single transient addition of H-2 to or removal of H-2 from the SCR feed it was found that the changes in the concentrations of gaseous species (products and reactants) were not matched by changes at comparable timescales of the concentration of surface species observed by IR This observation indicates that the majority of sur face species observed by DRIFTS under steady-state reaction conditions are spectators In contrast under fast cycling experimental conditions It was found that a surface isocyanate species had a temporal response that matched that of N-15(2) This suggests that some of the isocyanate species observed by infrared spectroscopy could be important intermediates in the hydrogen-assisted SCR reaction although it is emphasised that this may be dependent on the way in which the infrared spectra are obtained It is concluded that the use of fast transient cycling switching techniques may provide useful mechanistic information under certain circumstances.
Resumo:
Objectives: To estimate the proportion of cancer outpatients who visit a Complementary and Alternative Medicine (CAM) unit that is located within a conventional cancer treatment centre; to compare the characteristics of CAM unit visitors with those of all outpatients; to monitor the demand for 20 CAM therapies delivered by professionals, and the use of the CAM unit for waiting, gathering information and informal support from volunteer staff.
Design: Prospective, observational, over a six month period.
Setting: CAM unit within a NHS cancer treatment centre.
Main outcome measures: Utilisation of the CAM unit for 20 complementary therapies, and for waiting, gathering information, informal support; characteristics of CAM users compared with those of all cancer outpatients attending the cancer centre; predictors of CAM therapy use and frequent use.
Results: 761 (95% of those approached) people were recruited, 498 (65.4%) cancer patients, 202 (26.5%) relatives, 37 (4.8%) friends/carers, 24 (3.2%) staff. Women predominated (n = 560, 73.6%). Of all outpatients attending the cancer centre, 498 (15.8%) visited the CAM unit, 290 (9.2%) accessed therapies. Compared to all outpatients, those visiting the CAM unit were: younger (mean 63.7 vs. 58.4 years), more likely to be female (57.9% vs. 78.7%), have breast (14.8% vs. 51.9%), gynaecological (5.0% vs. 9.1%) cancer, live in local postal district (57.3% vs. 61.6%). Significant predictors of therapy use and frequent visits were being a patient, female, higher education, living closer to the cancer centre.
Conclusions: Despite easy access to CAM therapies, a relatively small number of people regularly used them, whilst a larger number selectively tried a few. The integrated CAM unit meets a demand for information and informal support. The findings inform emerging policy on integrating CAM and conventional cancer treatment to address psychosocial needs of people with cancer. More research is needed on why people do not use integrated CAM services and how charges affect demand. © 2008.
Resumo:
In remanufacturing, the supply of used products and the demand for remanufactured products are usually mismatched because of the great uncertainties on both sides. In this paper, we propose a dynamic pricing policy to balance this uncertain supply and demand. Specifically, we study a remanufacturer’s problem of pricing a single class of cores with random price-dependent returns and random demand for the remanufactured products with backlogs. We model this pricing task as a continuous-time Markov decision process, which addresses both the finite and infinite horizon problems, and provide managerial insights by analyzing the structural properties of the optimal policy. We then use several computational examples to illustrate the impacts of particular system parameters on pricing policy.
Resumo:
Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.
Resumo:
Ruthenium red, a di-mu-oxo-bridged ruthenium complex, and its oxidised form, ruthenium brown, have been studied as possible homogeneous redox catalysts for the oxidation of water to O2 by Ce(IV) ions in H2SO4 and HCIO4. In both media the Ce(IV) ions oxidised the ruthenium red to brown and, with excess of Ce(IV), decomposed the ruthenium brown irreversibly to product(s) with three weak absorption bands at 390, 523 and 593 nm. Only in HCIO4 did the decomposition product(s) appear to act as a stable O2 catalyst. Spectral evidence tentatively suggests that the active catalyst may be a hydrolysed Ru(IV) polymeric species. The rate of catalysis was proportional to the initial concentration of ruthenium red/brown and the activation energy was determined as 36 +/- 1 kJ mol-1 over the temperature range ambient to ca. 50-degrees-C. At temperatures greater than 50-degrees-C the O2 catalyst undergoes an irreversible thermal decomposition reaction.
Resumo:
Semicarbazide (SEM) was considered to be a characteristic protein-bound side-chain metabolite of the banned veterinary drug nitrofurazone and used as a marker of nitrofurazone abuse. It was recently discovered that SEM can arise in food from sources other than nitrofurazone. This uncertainty over the source of SEM may be overcome if alternative markers specific to tissue-bound nitrofurazone residues can be determined. The structure of nitrofurazone metabolites in vivo and particular proteins to which they are bound are not known. These proteins with altered structure due to the presence of the drug metabolites can be considered as potential alternative biomarkers of nitrofurazone abuse. The proteins implicated in the in vivo binding of nitrofurazone were separated and identified. A crude mixture of proteins extracted from the liver of a rat treated with the drug was separated using a series of different techniques such as preparative isoelectric focusing and size exclusion HPLC. Multiple fractions were assayed by LC-MS/MS to detect the presence of SEM. The proteins containing SEM residues were identified by peptide mass mapping using trypsin digestion and MALDI-TOF. The first protein identified as containing high concentration of SEM was albumin. It was also shown that low molecular weight species within a protein mixture whose main constituent was glutathione S-transferase contained a high concentration of SEM. The chemical composition of these components is under investigation. Preliminary data suggest the SEM forms part of a nitrofurazone metabolite conjugated to glutathione. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
cis- (3(cis)) and trans-2-(tetradec-5'-enyl)cyclobutanone (3(trans)) have been chemically synthesised and used in the unambiguous identification of the cis isomer 3(cis) in irradiated meat (example chicken) and fruit (example papaya). 11-(2'-Oxocyclobutyl)undecanoic acid 5 has been chemically synthesised, conjugated to bovine thyroglobulin and used to generate polyclonal antibodies in rabbits, which have been used in the development of an enzyme-linked immunosorbent assay for the detection of 2-substituted cyclobutanones in irradiated chicken meat.
Resumo:
The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.