Introduction
PET-computed tomography (PET-CT) is a useful staging imaging modality in colorectal liver metastases (CRLM). This study aimed to determine whether PET-CT parameters, standardized uptake value (SUV) and reconstructed tumour volume (RTV), are predictors of prognosis and survival.
Methods
A study of all resectable CRLM patients in the regional HPB unit from 2007–2009 was performed. Preoperative PET-CT scans were retrospectively reviewed; SUV, diameter and RTV for each lesion was recorded. Correlation analysis was performed with other pathological and biochemical parameters, by Pearson’s correlation analysis. Survival analysis was performed using Cox regression hazard model. A P value of less than 0.05 was considered statistically significant.
Results
A total of 79 patients were included. SUV moderately correlated with tumour diameter, both PET-CT (r=0.4927; P<0.0001) and histology (r=0.4513; P=0.0003); RTV (r=0.4489; P<0.001), preoperative carcinoembryonic antigen (CEA) (r=0.4977; P=0.0001), and postoperative CEA (r=0.3727; P=0.004). Multivariate analysis found that an independent predictor of SUVmax was preoperative CEA (P=0.03). RTV strongly correlated with preoperative CEA (r=0.9389; P<0.0001). SUV and RTV had a negative effect on survival.
Conclusion
PET-CT, in the setting of CRLM, may have a prognostic role in assessing survival. Although no definite conclusions can be drawn regarding the prognostic role of SUV and RTV, it acts to reinforce the need for further prospective studies to validate these findings.
Three dimensional morphology and compressive behaviour of sintered biodegradable composite scaffolds
Resumo:
Porous poly-L-lactide acid (PLA) scaffolds are prepared using polymer sintering and porogen leaching method. Different weight fractions of the Hydroxyapatite (HA) are added to the PLA to control the acidity and degradation rate. The three dimensional morphology and surface porosity are tested using micro CT, optical microscopy and scanning electron microscopy (SEM). Results indicate that the surface porosity does not change by addition of HA. The micro Ct examinations show slight decrease in the pore size and increase in wall thickness accompanied with reduced anisotropy for the scaffolds containing HA. SEM micrographs show detectable interconnected pores for the scaffold with pure PLA. Addition of the HA results in agglomeration of the HA which blocks some of the pores. Compression tests of the scaffold identify three stages in the stress-strain curve. The addition of HA adversely affects the modulus of the scaffold at the first stage, but this was reversed for the second and third stages of the compression. The results of these tests are compared with the cellular material model. The manufactured scaffold have acceptable properties for a scaffold, however improvement to the mixing of the phases of PLA and HA is required to achieve better integrity of the composite scaffolds.
Resumo:
Porous poly(L-lactic acid) (PLA) scaffolds of 85 per cent and 90 per cent porosity are prepared using polymer sintering and porogen leaching method. Different weight fractions of 10 per cent, 30 per cent, and 50 per cent of hydroxyapatite (HA) are added to the PLA to control the acidity and degradation rate. The three-dimensional (3D) morphology and surface porosity are tested using micro-computer tomography (micro-CT), optical microscopy, and scanning electron microscopy (SEM). Results indicate that the surface porosity does not change on the addition of HA. The micro-CT examinations show a slight decrease in the pore size and increase in the wall thickness accompanied by reduced anisotropy for the scaffolds containing HA. Scanning electron micrographs show detectable interconnected pores for the scaffold with pure PLA. Addition of the HA results in agglomeration of the HA particles and reduced leaching of the porogen. Compression tests of the scaffold identify three stages in the stress-strain curve. The addition of HA results in a reduction in the modulus of the scaffold at the first stage of elastic bending of the wall, but this is reversed for the second and third stages of collapse of the wall and densification in the compression tests. In the scaffolds with 85 per cent porosity, the addition of a high percentage of HA could result in 70 per cent decrease in stiffness in the first stage, 200 per cent increase in stiffness in the second stage, and 20 per cent increase in stiffness in the third stage. The results of these tests are compared with the Gibson cellular material model that is proposed for prediction of the behaviour of cellular material under compression. The pH and molecular weight changes are tracked for the scaffolds within a period of 35 days. The addition of HA keeps the pH in the alkaline region, which results in higher rate of degradation at an early period of observation, followed by a reduced rate of degradation later in the process. The final molecular weight is higher for the scaffolds with HA than for scaffolds of pure PLA. The manufactured scaffolds offer acceptable properties in terms of the pore size range and interconnectivity of the pores and porosity for non-load-bearing bone graft substitute; however, improvement to the mixing of the phases of PLA and HA is required to achieve better integrity of the composite scaffolds. © 2008 IMechE.
Resumo:
This paper reports image analysis methods that have been developed to study the microstructural changes of non-wovens made by the hydroentanglement process. The validity of the image processing techniques has been ascertained by applying them to test images with known properties. The parameters in preprocessing of the scanning electron microscope (SEM) images used in image processing have been tested and optimized. The fibre orientation distribution is estimated using fast Fourier transform (FFT) and Hough transform (HT) methods. The results obtained using these two methods are in good agreement. The HT method is more demanding in computational time compared with the Fourier transform (FT) method. However, the advantage of the HT method is that the actual orientation of the lines can be concluded directly from the result of the transform without the need for any further computation. The distribution of the length of the straight fibre segments of the fabrics is evaluated by the HT method. The effect of curl of the fibres on the result of this evaluation is shown.
Resumo:
The image analysis techniques developed in Part 1 to study microstructural changes in non-woven fabrics are applied to measure the fibre orientation distribution and fibre length distribution of hydroentangled fabrics. The results are supported by strength and modulus measurements using samples from the same fabrics. It is shown that the techniques developed can successfully be used to assess the degree of entanglement of hydroentangled fabrics regardless of their thickness.
Resumo:
Doses from CT examinations are difficult to estimate. However, they are requested more frequently due to the increase in CT examinations. In particular, fetal dose estimations are frequently required for patients who have discovered, subsequent to the examination, that they were pregnant when the examination was conducted. A computer model has been developed to facilitate such dose calculations. This model combines empirical beam data with anatomical information. The model has been verified using thermoluminescent dosemeter (TLD) readings of internal and surface dose from both phantoms and patients, including intrauterine doses for patients undergoing afterloading gynaecological intracavitary treatment. Although only limited experimental data were available, the results indicate that the model accurately predicts uterine doses within acceptable errors. This approach has been validated for fetal dose estimation. The model was also used in a comparison with the nationally available CT dose data from the National Radiological Protection Board (NRPB). The two models were found to be in agreement for fetal dose estimations.
Resumo:
Two recent scanning probe techniques were applied to investigate the bipolar twin state of 4-iodo-4'-nitrobiphenyl (INBP) crystals. Solution grown crystals of INBP show typically a morphology which does not express that of a mono-domain polar structure (Fdd2, mm2). From previous X-ray diffraction a twinning volume ratio of similar to 70 : 30 is now explained by two unipolar domains (Flack parameter: 0.075(29)) of opposite orientation of the molecular dipoles, joined by a transition zone showing a width of similar to 140 mm. Scanning pyroelectric microscopy (SPEM) demonstrates a continuous transition of the polarization P from +P into -P across the zone. Application of piezoelectric force microscopy (PFM) confirms unipolar alignment of INBP molecules down to a resolution of similar to 20 nm. A previously proposed real structure for INBP crystals built from lamellae with antiparallel alignment is thus rejected. Anomalous X-ray scattering was used to determine the absolute molecular orientation in the two domains. End faces of the polar axis 2 are thus made up by NO2 groups. Using a previously determined negative pyroelectric coefficient pc leads to a confirmation also by a SPEM analysis. Calculated values for functional group interactions (D...A), (A...A), (D...D) and the stochastic theory of polarity formation allow us to predict that NO2 groups should terminate corresponding faces. Following the present analysis, INBP may represent a first example undergoing dipole reversal upon growth to end up in a bipolar state.
Resumo:
A novel diffusive gradients in thin film probe developed comprises diffusive gel layer of silver iodide (AgI) and a back-up Microchelex resin gel layer. 2D high-resolution images of sulfide and trace metals were determined respectively on the AgI gel by densitometric analysis and on the Microchelex resin layer with laser-ablation-inductively-coupled plasma mass spectrometry (LA-ICP-MS).We investigated the validity of the analytical procedures used for the determination of sulfide and trace metals. We found low relative standard deviations on replicate measurements, linear trace-metal calibration curves between the LA-ICP-MS signal and the true trace-metal concentration in the resin gel, and a good agreement of the sulfide results obtained with the AgI resin gel and with other analytical methods. The method was applied on anoxic sediment pore waters in an estuarine and marine system. Simultaneous remobilization of sulfide and trace metals was observed in the marine sediment.
Resumo:
The operational lifetime of hip replacement prostheses can be severely limited due to the occurrence of excessive wear at the load-bearing interfaces. The aim of this study was to investigate how the surface topography of articulating counterfaces evolves over the duration of a laboratory wear run. It was observed that modular stainless steel femoral heads wearing against ultrahigh molecular weight polyethylene (UHMWPE) can themselves be subject to wearing. A comparison with retrieved in vivo-aged femoral heads shows many topographical similarities: in a qualitative sense, scratching and pitting are evident on laboratory and in vivo-worn femoral heads; quantitatively, roughness comparisons between the new and worn devices are seen to increase typically by a factor of 4 after laboratory wearing. The observations suggest that a particular wear mode, namely third-body wear, is responsible for the increased roughness. It is conjectured that third bodies might arise through surface fatigue wear on the metal counterface, Wear debris is also observed to have been generated from the polymer surface, creating rounded debris with sizes predominantly in the range 0.4-0.8 microns: dimensions that are comparable to values previously reported for in vivo generated debris.
Resumo:
The spectroscopic capability of the photon scanning tunneling microscope is exploited to study directly the launch and propagation of surface plasmons on thin silver films. Two input beams, of different wavelength, are incident through the prism in a prism-Ag film-air-fibre tip system. Both excite surface plasmons at the Ag-air interface and light of both wavelengths is coupled into the fibre probe via the respective surface plasmon evanescent fields. One laser beam is used for instrument control. The second, or probe beam is tightly focused on the sample, within the area of the unfocused or control beam, giving a well-defined and symmetrical, confined surface plasmon launch site. However, the image at the probe wavelength is highly asymmetrical in section with an exponential tail extending beyond one side of the launch site. This demonstrates in a very direct fashion;the propagation of surface plasmons; a propagation length of similar to 11.7 mu m is measured at a probe wavelength of 543.5 nm. On rough Ag films the excitation of localised scattering centres is also observed in addition to the launch of delocalised surface plasmons.