121 resultados para AIR-ABRASION
Resumo:
Electroless nickel (EN) and electroless nickel composite (ENC) coatings were deposited on aluminium alloy substrate, LM24. The micro abrasion test was conducted to study the wear behaviour of the coatings with the effect of SiC concentration. Microhardness of the coatings was tested also. The wear scars were analysed using optical microscope and scanning electron microscope (SEM). The wear resistance was found to be improved in composite coating that has higher microhardness as compared to particles free and the bare aluminium substrate. In as-deposited condition for the composite coating, the wear volume increases on increase in SiC percentage in the coating but is found to be minimum for lower SiC percentage. The increase in hardness on heat treatment at 400°C is due to the hardening or grain coarsening with the formation Ni3P.
Resumo:
This paper describes a study that used video materials and visits to an airport to prepare children on the autism spectrum for travel by plane. Twenty parents and carers took part in the study with children aged from 3 to 16 years. The authors explain that the methods they used were based on Applied Behaviour Analysis (ABA) research; a video modeling technique called Point-Of-View Video-priming and during visits to an airport they used procedures known as Natural Environment Teaching. The findings suggest that using video and preparing children by taking them through what is likely to happen in the real environment when they travel by plane is effective and the authors suggest these strategies could be used to support children with autism with other experiences they need or would like to engage in such as visits to the dentist or hairdressers and access to leisure centres and other public spaces.
Resumo:
A microcosm system was developed to investigate transfers of organic xenobiotics in air-soil-plant systems. This was validated using 14C labelled 1,2-dichlorobenzene (DCB) as a model compound. Trapping efficiency was 106 ± 3% for volatile compounds and 93.0 ± 2.2% for carbon dioxide in a blank microcosm arrangement. Recovery of 1,2-dichlorobenzene spiked to grassed and unplanted soils was > 90% after 1 week. The predominant DCB loss process was volatilisation with no evidence for mineralisation over 1 week and 20-30% of the added spike remained in soil. Although there was no evidence for root uptake and translocation of added label, foliar uptake of soil volatilised compound was detected. The microcosm showed good potential for study of 14C labelled and unlabelled organic xenobiotic transfers in air-soil-plant systems with single plants and also intact planted cores.
Resumo:
The purpose of this study is to determine the influence of inclining the heat exchanger relative to the fan in a forced draught air-cooled heat exchanger. Since inclination increases plenum depth, the effect of inclination is also compared with increasing plenum depth without inclination. The experimental study shows that inclination improves thermal performance by only 0.5%, when compared with a baseline non-inclined case with a shallow plenum. Similarly, increasing plenum depth without inclination has a thermal performance benefit of approximately 1%. The numerical study shows that, as the heat exchanger is inclined, the low velocity core at the centre of the heat exchanger moves to one side.
Resumo:
This paper describes large scale tests conducted on a novel unglazed solar air collector system. The proposed system, referred to as a back-pass solar collector (BPSC), has on-site installation and aesthetic advantages over conventional unglazed transpired solar collectors (UTSC) as it is fully integrated within a standard insulated wall panel. This paper presents the results obtained from monitoring a BPSC wall panel over one year. Measurements of temperature, wind velocity and solar irradiance were taken at multiple air mass flow rates. It is shown that the length of the collector cavities has a direct impact on the efficiency of the system. It is also shown that beyond a height-to-flow ratio of 0.023m/m<sup>3</sup>/hr/m<sup>2</sup>, no additional heat output is obtained by increasing the collector height for the experimental setup in this study, but these numbers would obviously be different if the experimental setup or test environment (e.g. location and climate) change. An equation for predicting the temperature rise of the BPSC is proposed.
Resumo:
Glazed Double Skin Facades (DSF) offer the potential to improve the performance of all-glass building skins, common to commercial office buildings in which full facade glazing has almost become the standard. Single skin glazing results in increased heating and cooling costs over opaque walls, due to lower thermal resistance of glass, and the increased impact of solar gain through it. However, the performance benefit of DSF technology continues to be questioned and its operation poorly understood, particularly the nature of airflow through the cavity. This paper deals specifically with the experimental analysis of the air flow characteristics in an automated double skin façade. The benefit of the DSF as a thermal buffer, and to limit overheating is evaluated through analysis of an extensive set of parameters including air and surface temperatures at each level in the DSF, airflow readings in the cavity and at the inlet and outlet, solar and wind data, and analytically derived pressure differentials. The temperature and air-flow are monitored in the cavity of a DSF using wireless sensors and hot wire anemometers respectively. Automated louvre operation and building set-points are monitored via the BMS. Thermal stratification and air flow variation during changing weather conditions are shown to effect the performance of the DSF considerably and hence the energy performance of the building. The relative pressure effects due to buoyancy and wind are analysed and quantified. This research aims to developed and validate models of DSFs in the maritime climate, using multi-season data from experimental monitoring. This extensive experimental study provides data for training and validation of models.
Resumo:
This paper reports on the accuracy of new test methods developed to measure the air and water permeability of high-performance concretes (HPCs). Five representative HPC and one normal concrete (NC) mixtures were tested to estimate both repeatability and reliability of the proposed methods. Repeatability acceptance was adjudged using values of signal-noise ratio (SNR) and discrimination ratio (DR), and reliability was investigated by comparing against standard laboratory-based test methods (i.e., the RILEM gas permeability test and BS EN water penetration test). With SNR and DR values satisfying recommended criteria, it was concluded that test repeatability error has no significant influence on results. In addition, the research confirmed strong positive relationships between the proposed test methods and existing standard permeability assessment techniques. Based on these findings, the proposed test methods show strong potential to become recognized as international methods for determining the permeability of HPCs.
Resumo:
This paper reports on the solubility and diffusivity of dissolved oxygen in a series of ionic liquids (ILs) based on the bis{(trifluoromethyl)sulfonyl}imide anion with a range of related alkyl and ether functionalised cyclic alkylammonium cations. Cyclic voltammetry has been used to observe the reduction of oxygen in ILs at a microdisk electrode and chronoamperometric measurements have then been applied to simultaneously determine both the concentration and the diffusion coefficient of oxygen in the different ILs. The viscosity of the ILs and the calculated molar volume and free volume is also reported. It is found that, within this class of ILs, the oxygen diffusivity generally increases with decreasing viscosity of the neat IL. An inverse relationship between oxygen solubility and IL free volume is reported for the two IL families implying oxygen is not simply occupying the available empty space. In addition, it is reported that the introduction of ether-group into the IL cation structure promotes the diffusivity of dissolved oxygen but reduces the solubility of the gas.
Resumo:
There is a significant lack of indoor air quality research in low energy homes. This study compared the indoor air quality of eight
newly built case study homes constructed to similar levels of air-tightness and insulation; with two different ventilation strategies (four homes with Mechanical Ventilation with Heat Recovery (MVHR) systems/Code level 4 and four homes naturally ventilated/Code level 3). Indoor air quality measurements were conducted over a 24 h period in the living room and main bedroom of each home during the summer and winter seasons. Simultaneous outside measurements and an occupant diary were also employed during the measurement period. Occupant interviews were conducted to gain information on perceived indoor air quality, occupant behaviour and building related illnesses. Knowledge of the MVHR system including ventilation related behaviour was also studied. Results suggest indoor air quality problems in both the mechanically ventilated and naturally ventilated homes, with significant issues identified regarding occupant use in the social homes
Resumo:
The use of sustainable assessment methods in the UK is on the rise, anticipating the future regulatory trajectory towards zero carbon by 2016. The indisputable influence of sustainable rating tools on UK building regulations conveys the importance of evaluating their effectiveness in achieving true sustainable design, without adversely effecting human health and wellbeing. This paper reviews indoor air-quality (IAQ) issues addressed by UK sustainable assessment tools, and the potential trade-offs between building energy conservation and IAQ. The barriers to effective adoption of IAQ strategies are investigated, including recommendations, suggestions, and future research needs. The review identified a fundamental lack of IAQ criteria in sustainable assessment tools aimed at the residential sector. The consideration of occupants’ health and well-being should be paramount in any assessment scheme, and should not be overshadowed or obscured by the drive towards energy efficiency. A balance is essential.