Background: The COMET (Core Outcome Measures in Effectiveness Trials) Initiative is developing a publicly accessible online resource to collate the knowledge base for core outcome set development (COS) and the applied work from different health conditions. Ensuring that the database is as comprehensive as possible and keeping it up to date are key to its value for users. This requires the development and application of an optimal, multi-faceted search strategy to identify relevant material. This paper describes the challenges of designing and implementing such a search, outlining the development of the search strategy for studies of COS development, and, in turn, the process for establishing a database of COS.

Methods: We investigated the performance characteristics of this strategy including sensitivity, precision and numbers needed to read. We compared the contribution of databases towards identifying included studies to identify the best combination of methods to retrieve all included studies.

Results: Recall of the search strategies ranged from 4% to 87%, and precision from 0.77% to 1.13%. MEDLINE performed best in terms of recall, retrieving 216 (87%) of the 250 included records, followed by Scopus (44%). The Cochrane Methodology Register found just 4% of the included records. MEDLINE was also the database with the highest precision. The number needed to read varied between 89 (MEDLINE) and 130 (SCOPUS).

Conclusions: We found that two databases and hand searching were required to locate all of the studies in this review. MEDLINE alone retrieved 87% of the included studies, but actually 97% of the included studies were indexed on MEDLINE. The Cochrane Methodology Register did not contribute any records that were not found in the other databases, and will not be included in our future searches to identify studies developing COS. SCOPUS had the lowest precision rate (0.77) and highest number needed to read (130). In future COMET searches for COS a balance needs to be struck between the work involved in screening large numbers of records, the frequency of the searching and the likelihood that eligible studies will be identified by means other than the database searches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To quantify variability in hand proportioning of zinc phosphate cement among a cohort of dental undergraduates and to determine the effect of any such variability on the diametral tensile strength (DTS) of the set cement. The null hypothesis was that such variability has no effect on DTS. 
Methods: Thirty-four operators dispensed a zinc phosphate cement [Fleck's® Cement] according to the manufacturers' instructions. The mass of powder and liquid dispensed was recorded. Cylindrical specimens (n = 2 x 34) of dimensions 6mm x 3mm were prepared using a stainless steel split mould. The maximum mass of powder and the minimum volume of liquid were used as one extreme ratio and the minimum mass of powder and the maximum volume of liquid used on the other extreme. The manufacturers' recommended ratio was also tested (n=34).The samples were left to set for one hour before being transferred into distilled water for 48 hours. Compression across a diameter was carried out using a universal testing machine, H10KS [Tinius Olsen], at a constant crosshead speed of 0.75 ±0.25 mm/min. Statistical analyses (α = 0.05) were by Student's t-test for the powder/liquid ratio and one-way ANOVA and Tukey HSD for for pair-wise comparisons of mean DTS. Tests were carried out for normality and constant variability. 
Results: The mean (range) amount of powder dispensed was 0.863g (0.531-1.216)g. The mean (range) amount of liquid dispensed was 0.341ml (0.265-0.394)ml. The manufacturer's recommended amounts were 0.8g of powder and 0.3ml of liquid. The mean powder/liquid ratio was not significantly different from the manufacturer's recommended value (p=0.64). Mean (SD) DTS were (MPa) max: 7.19(1.50), min: 2.65(1.01), manufacturer: 6.01(1.30). All pair-wise comparisons were significantly different (p<0.001). 
Conclusions: Variability exists in the hand proportioning powder and liquid components of zinc phosphate cement. This variability can affect the DTS of zinc phosphate cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within the last decade, due to significant improvements in the spatial and temporal resolution of chromospheric data, magneto hydrodynamic (MHD)wave studies in this fascinating region of the Sun's atmosphere have risen to the forefront of solar physics research. In this review we begin by reviewing the challenges and debates that have manifested in relation to MHD wave mode identification in fine-scale chromosphericmagnetic structures, including spicules, fibrils and mottles. Next we goon to discuss how the process of accurately identifying MHD wave modes also has a crucial role to play in estimating their wave energy flux.This is of cardinal importance for estimating what the possible contribution of MHD waves is to solar atmospheric heating. Finally, we detail how such advances in chromospheric MHD wave studies have also allowed us, for the first time, to implement cutting-edge magneto seismological techniques that provide new insight into the sub-resolution plasma structuring of the lower solar atmosphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Intermediate care (IC) describes a range of services targeted at older people, aimed at preventing unnecessary hospitalisation, promoting faster recovery from illness and maximising independence. Older people are at increased risk of medication-related adverse events, but little is known about the provision of medicines management services in IC facilities. This study aimed to describe the current provision of medicines management services in IC facilities in Northern Ireland (NI) and to explore healthcare workers' (HCWs) and patients' views of, and attitudes towards these services and the IC concept. 

Methods: Semi-structured interviews were conducted, recorded, transcribed verbatim and analysed using a constant comparative approach with HCWs and patients from IC facilities in NI. 

Results: Interviews were conducted with 25 HCWs and 18 patients from 12 IC facilities in NI. Three themes were identified: 'concept and reality', 'setting and supply' and 'responsibility and review'. A mismatch between the concept of IC and the reality was evident. The IC facility setting dictated prescribing responsibilities and the supply of medicines, presenting challenges for HCWs. A lack of a standardised approach to responsibility for the provision of medicines management services including clinical review was identified. Whilst pharmacists were not considered part of the multidisciplinary team, most HCWs recognised a need for their input. Medicines management was not a concern for the majority of IC patients. 

Conclusions: Medicines management services are not integral to IC and medicine-related challenges are frequently encountered. Integration of pharmacists into the multidisciplinary team could potentially improve medicines management in IC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioresorbable polymers increasingly are the materials of choice for implantable orthopaedic fixation devices. Controlled degradation of these polymers is vital for preservation of mechanical properties during tissue repair and controlled release of incorporated agents such as osteoconductive or anti-microbial additives. The work outlined in this paper investigates the use of low energy electron beam irradiation to surface modify polyhydroxyacid samples incorporating beta tricalcium phosphate (β-TCP). This work uniquely demonstrates that surface modification of bioresorbable polymers through electron beam irradiation allows for the early release of incorporated agents such as bioactive additives. Samples were e-beam irradiated at an energy of 125 keV and doses of either 150 kGy or 500 kGy. Irradiated and non-irradiated samples were degraded in phosphate buffered saline (PBS), to simulate bioresorption, followed by characterisation. The results show that low energy e-beam irradiation enhances surface hydrolytic degradation in comparison to bulk and furthermore allows for earlier release of incorporated calcium via dissolution into the surrounding medium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some reasons for registering trials might be considered as self-serving, such as satisfying the requirements of a journal in which the researchers wish to publish their eventual findings or publicising the trial to boost recruitment. Registry entries also help others, including systematic reviewers, to know about ongoing or unpublished studies and contribute to reducing research waste by making it clear what studies are ongoing. Other sources of research waste include inconsistency in outcome measurement across trials in the same area, missing data on important outcomes from some trials, and selective reporting of outcomes. One way to reduce this waste is through the use of core outcome sets: standardised sets of outcomes for research in specific areas of health and social care. These do not restrict the outcomes that will be measured, but provide the minimum to include if a trial is to be of the most use to potential users. We propose that trial registries, such as ISRCTN, encourage researchers to note their use of a core outcome set in their entry. This will help people searching for trials and those worried about selective reporting in closed trials. Trial registries can facilitate these efforts to make new trials as useful as possible and reduce waste. The outcomes section in the entry could prompt the researcher to consider using a core outcome set and facilitate the specification of that core outcome set and its component outcomes through linking to the original core outcome set. In doing this, registries will contribute to the global effort to ensure that trials answer important uncertainties, can be brought together in systematic reviews, and better serve their ultimate aim of improving health and well-being through improving health and social care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: A core outcome set (COS) can address problems of outcome heterogeneity and outcome reporting bias in trials and systematic reviews, including Cochrane reviews, helping to reduce waste. One of the aims of the international Core Outcome Measures in Effectiveness Trials (COMET) Initiative is to link the development and use of COS with the outcomes specified and reported in Cochrane reviews, including the outcomes listed in the summary of findings (SoF) tables. As part of this work, an earlier exploratory survey of the outcomes of newly published 2007 and 2011 Cochrane reviews was performed. This survey examined the use of COS, the variety of specified outcomes, and outcome reporting in Cochrane reviews by Cochrane Review Group (CRG). To examine changes over time and to explore outcomes that were repeatedly specified over time in Cochrane reviews by CRG, we conducted a follow-up survey of outcomes in 2013 Cochrane reviews.

METHODS: A descriptive survey of outcomes in Cochrane reviews that were first published in 2013. Outcomes specified in the methods sections and reported in the results section of the Cochrane reviews were examined by CRG. We also explored the uptake of SoF tables, the number of outcomes included in these, and the quality of the evidence for the outcomes.

RESULTS: Across the 50 CRGs, 375 Cochrane reviews that included at least one study specified a total of 3142 outcomes. Of these outcomes, 32 % (1008) were not reported in the results section of these reviews. For 23 % (233) of these non-reported outcomes, we did not find any reason in the text of the review for this non-report. Fifty-seven percent (216/375) of reviews included a SoF table.

CONCLUSIONS: The proportion of specified outcomes that were reported in Cochrane reviews had increased in 2013 (68 %) compared to 2007 (61 %) and 2011 (65 %). Importantly, 2013 Cochrane reviews that did not report specified outcomes were twice as likely to provide an explanation for why the outcome was not reported. There has been an increased uptake of SoF tables in Cochrane reviews. Outcomes that were repeatedly specified in Cochrane reviews by CRG in 2007, 2011, and 2013 may assist COS development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Improved prostate cancer (PCa)-specific biomarkers are urgently required to distinguish between indolent and aggressive disease, in order to avoid overtreatment. In this study, we investigated the prostatic tissue expression of secreted frizzled-related protein (SFRP)-2.

METHODS AND RESULTS: Following immunohistochemical analysis on PCa tissue microarrays with samples from 216 patients, strong/moderate SFRP-2 expression was observed in epithelial cells of benign prostatic hyperplasia, and negative/weak SFRP-2 expression was observed in the majority of tumour epithelia. However, among Gleason grade 5 carcinomas, 40% showed strong/moderate SFRP-2 expression and 60% showed negative SFRP-2 expression in epithelial cells. Further microscopic evaluation of Gleason grade 5 tumours revealed different morphological patterns, corresponding with differential SFRP-2 expression. The first subgroup (referred to as Type A) appeared to have a morphologically solid growth pattern, whereas the second subgroup (referred to as Type B) appeared to have a more diffuse pattern. Furthermore, 100% (4/4) of Type A patients experienced biochemical recurrence, as compared with 0% (0/6) of Type B patients.

CONCLUSIONS: These results imply: (i) that there is a loss of SFRP-2 expression from benign to malignant prostate glands; and (ii) differential SFRP-2 expression among two possible subgroups of Gleason grade 5 tumours.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breast cancer is a heterogeneous disease and several distinct subtypes exist based on differential gene expression patterns. Molecular apocrine tumours were recently identified as an additional subgroup, characterised as oestrogen receptor negative and androgen receptor positive (ER- AR+), but with an expression profile resembling ER+ luminal breast cancer. One possible explanation for the apparent incongruity is that ER gene expression programmes could be recapitulated by AR. Using a cell line model of ER- AR+ molecular apocrine tumours (termed MDA-MB-453 cells), we map global AR binding events and find a binding profile that is similar to ER binding in breast cancer cells. We find that AR binding is a near-perfect subset of FoxA1 binding regions, a level of concordance never previously seen with a nuclear receptor. AR functionality is dependent on FoxA1, since silencing of FoxA1 inhibits AR binding, expression of the majority of the molecular apocrine gene signature and growth cell growth. These findings show that AR binds and regulates ER cis-regulatory elements in molecular apocrine tumours, resulting in a transcriptional programme reminiscent of ER-mediated transcription in luminal breast cancers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Porous solids such as zeolites and metal-organic frameworks are useful in molecular separation and in catalysis, but their solid nature can impose limitations. For example, liquid solvents, rather than porous solids, are the most mature technology for post-combustion capture of carbon dioxide because liquid circulation systems are more easily retrofitted to existing plants. Solid porous adsorbents offer major benefits, such as lower energy penalties in adsorption-desorption cycles, but they are difficult to implement in conventional flow processes. Materials that combine the properties of fluidity and permanent porosity could therefore offer technological advantages, but permanent porosity is not associated with conventional liquids. Here we report free-flowing liquids whose bulk properties are determined by their permanent porosity. To achieve this, we designed cage molecules that provide a well-defined pore space and that are highly soluble in solvents whose molecules are too large to enter the pores. The concentration of unoccupied cages can thus be around 500 times greater than in other molecular solutions that contain cavities, resulting in a marked change in bulk properties, such as an eightfold increase in the solubility of methane gas. Our results provide the basis for development of a new class of functional porous materials for chemical processes, and we present a one-step, multigram scale-up route for highly soluble 'scrambled' porous cages prepared from a mixture of commercially available reagents. The unifying design principle for these materials is the avoidance of functional groups that can penetrate into the molecular cage cavities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Arteriovenous fistula (AVF) failure to mature (FTM) rates contribute to excessive dependence on central venous catheters for haemodialysis. Choosing the most appropriate vascular access site for an individual patient is guided largely by their age, co-morbidities and clinical examination. We investigated the clinical predictors of AVF FTM in a European cohort of patients and applied an existing clinical risk prediction model for AVF FTM to this population.
Methods: A prospective cohort study was designed that included all patients undergoing AVF creation between January 2009 and December 2014 in a single centre (Belfast City Hospital) who had a functional AVF outcome observed by March 2015.
Results: A total of 525 patients had a functional AVF outcome recorded and were included in the FTM analysis. In this cohort, 309 (59%) patients achieved functional AVF patency and 216 (41%) patients had FTM. Female gender [P < 0.001, odds ratio (OR) 2.03 (CI 1.37–3.02)] and lower-arm AVF [P < 0.001, OR 4.07 (CI 2.77–5.92)] were associated with AVF FTM. The Lok model did not predict FTM outcomes based on the associated risk stratification in our population.
Conclusions: In this European study, female gender was associated with twice the risk of AVF FTM and a lower-arm AVF with four times the risk of FTM. The FTM risk prediction model was not found to be discriminative in this population. Clinical risk factors for AVF FTM vary between populations;we would recommend that units investigate their own clinical predictors of FTM to maximize AVF functional patency and ultimately survival in dialysis patients. Clinical predictors of AVF FTM may not be sufficient on their own to improve vascular access functional patency rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to its complex and dynamic fine-scale structure, the chromosphere is a particularly challenging region of the Sun's atmosphere to understand. It is now widely accepted that to model chromospheric dynamics, even on a magnetohydrodynamic (MHD) scale, while also calculating spectral line emission, one must realistically include the effects of partial ionization and radiative transfer in a multi-fluid plasma under non-LTE conditions. Accurate quantification of MHD wave energetics must befounded on a precise identification of the actual wave mode being observed. This chapter focuses on MHD kink-mode identification, MHD sausage mode identification, and MHD torsional Alfvén wave identification. It then reviews progress in determining more accurate energy flux estimations of specific MHD wave modes observed in the chromosphere. The chapter finally examines how the discovery of these MHD wave modes has helped us advance the field of chromosphericmagnetoseismology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This chapter reviews the recent observations of waves and oscillations manifesting in fine-scale magnetic structures in the solar photosphere, which are often interpreted as the "building blocks' of the magnetic Sun. The authors found, through phase relationships between the various waveforms, that small-scale magnetic bright points (MBPs) in the photosphere demonstrated signatures of specific magnetoacoustic waves, in particular the sausage and kink modes. Modern magnetohydrodynamic (MHD) simulations of the lower solar atmosphere clearly show how torsional motions can easily be induced in magnetic elements in the photosphere through the processes of vortical motions and/or buffeting by neighboring granules. The authors detected significant power associated with high-frequency horizontal motions, and suggested that these cases may be especially important in the creation of a turbulent environment that efficiently promotes Alfvén wave dissipation.