110 resultados para 343.077


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The optimal ways of using aromatase inhibitors or tamoxifen as endocrine treatment for early breast cancer remains uncertain.

METHODS: We undertook meta-analyses of individual data on 31 920 postmenopausal women with oestrogen-receptor-positive early breast cancer in the randomised trials of 5 years of aromatase inhibitor versus 5 years of tamoxifen; of 5 years of aromatase inhibitor versus 2-3 years of tamoxifen then aromatase inhibitor to year 5; and of 2-3 years of tamoxifen then aromatase inhibitor to year 5 versus 5 years of tamoxifen. Primary outcomes were any recurrence of breast cancer, breast cancer mortality, death without recurrence, and all-cause mortality. Intention-to-treat log-rank analyses, stratified by age, nodal status, and trial, yielded aromatase inhibitor versus tamoxifen first-event rate ratios (RRs).

FINDINGS: In the comparison of 5 years of aromatase inhibitor versus 5 years of tamoxifen, recurrence RRs favoured aromatase inhibitors significantly during years 0-1 (RR 0·64, 95% CI 0·52-0·78) and 2-4 (RR 0·80, 0·68-0·93), and non-significantly thereafter. 10-year breast cancer mortality was lower with aromatase inhibitors than tamoxifen (12·1% vs 14·2%; RR 0·85, 0·75-0·96; 2p=0·009). In the comparison of 5 years of aromatase inhibitor versus 2-3 years of tamoxifen then aromatase inhibitor to year 5, recurrence RRs favoured aromatase inhibitors significantly during years 0-1 (RR 0·74, 0·62-0·89) but not while both groups received aromatase inhibitors during years 2-4, or thereafter; overall in these trials, there were fewer recurrences with 5 years of aromatase inhibitors than with tamoxifen then aromatase inhibitors (RR 0·90, 0·81-0·99; 2p=0·045), though the breast cancer mortality reduction was not significant (RR 0·89, 0·78-1·03; 2p=0·11). In the comparison of 2-3 years of tamoxifen then aromatase inhibitor to year 5 versus 5 years of tamoxifen, recurrence RRs favoured aromatase inhibitors significantly during years 2-4 (RR 0·56, 0·46-0·67) but not subsequently, and 10-year breast cancer mortality was lower with switching to aromatase inhibitors than with remaining on tamoxifen (8·7% vs 10·1%; 2p=0·015). Aggregating all three types of comparison, recurrence RRs favoured aromatase inhibitors during periods when treatments differed (RR 0·70, 0·64-0·77), but not significantly thereafter (RR 0·93, 0·86-1·01; 2p=0·08). Breast cancer mortality was reduced both while treatments differed (RR 0·79, 0·67-0·92), and subsequently (RR 0·89, 0·81-0·99), and for all periods combined (RR 0·86, 0·80-0·94; 2p=0·0005). All-cause mortality was also reduced (RR 0·88, 0·82-0·94; 2p=0·0003). RRs differed little by age, body-mass index, stage, grade, progesterone receptor status, or HER2 status. There were fewer endometrial cancers with aromatase inhibitors than tamoxifen (10-year incidence 0·4% vs 1·2%; RR 0·33, 0·21-0·51) but more bone fractures (5-year risk 8·2% vs 5·5%; RR 1·42, 1·28-1·57); non-breast-cancer mortality was similar.

INTERPRETATION: Aromatase inhibitors reduce recurrence rates by about 30% (proportionately) compared with tamoxifen while treatments differ, but not thereafter. 5 years of an aromatase inhibitor reduces 10-year breast cancer mortality rates by about 15% compared with 5 years of tamoxifen, hence by about 40% (proportionately) compared with no endocrine treatment.

FUNDING: Cancer Research UK, Medical Research Council.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Stereotactic ablative radiotherapy (SABR) has become standard for inoperable early-stage non-small cell lung cancer (NSCLC). However, there is no randomized evidence demonstrating benefit over more fractionated radiotherapy. We compared accelerated hypofractionation (AH) and SABR using a propensity score-matched analysis.

MATERIALS AND METHODS: From 1997-2007, 119 patients (T1-3N0M0 NSCLC) were treated with AH (48-60Gy, 12-15 fractions). Prior to SABR, this represented our institutional standard. From 2008-2012, 192 patients (T1-3N0M0 NSCLC) were treated with SABR (48-52Gy, 4-5 fractions). A total of 114 patients (57 per cohort) were matched (1:1 ratio, caliper: 0.10) using propensity scores.

RESULTS: Median follow-up (range) for the AH cohort was 36.3 (2.5-109.1) months, while that for the SABR group was 32.5 (0.3-62.6)months. Three-year overall survival (OS) and local control (LC) rates were 49.5% vs. 72.4% [p=0.024; hazard ratio (HR): 2.33 (1.28, 4.23), p=0.006] and 71.9% vs. 89.3% [p=0.077; HR: 5.56 (1.53, 20.2), p=0.009], respectively. On multivariable analysis, tumour diameter and PET staging were predictive for OS, while the only predictive factor for LC was treatment cohort.

CONCLUSIONS: OS and LC were improved with SABR, although OS is more closely related to non-treatment factors. This represents one of the few studies comparing AH to SABR for early-stage lung cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

γ-Ray sources are among the most fundamental experimental tools currently available to modern physics. As well as the obvious benefits to fundamental research, an ultra-bright source of γ-rays could form the foundation of scanning of shipping containers for special nuclear materials and provide the bases for new types of cancer therapy.

However, for these applications to prove viable, γ-ray sources must become compact and relatively cheap to manufacture. In recent years, advances in laser technology have formed the cornerstone of optical sources of high energy electrons which already have been used to generate synchrotron radiation on a compact scale. Exploiting the scattering induced by a second laser, one can further enhance the energy and number of photons produced provided the problems of synchronisation and compact γ-ray detection are solved.

Here, we report on the work that has been done in developing an all-optical and hence, compact non-linear Thomson scattering source, including the new methods of synchronisation and compact γ-ray detection. We present evidence of the generation of multi-MeV (maximum 16–18 MeV) and ultra-high brilliance (exceeding 1020 photons s−1mm−2mrad−2 0.1% BW at 15 MeV) γ-ray beams. These characteristics are appealing for the paramount practical applications mentioned above.