255 resultados para reactive attachment disorder


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study reports the development, characterisation and microbiological testing of surface-modified polyvinylchloride (PVC) films for the purpose of reducing bacterial adherence.

METHODS: Irreversible covalent surface modification was achieved via nucleophilic substitution of fluorinated thiol-terminated compounds onto the polymer backbone. Four fluorinated modifiers, 2,3,5,6-tetrafluorothiophenol (TFTP), 4-(trifluoromethyl)thiophenol (TFMTP), 3,5-bis(trifluoromethyl)benzenethiol (BTFMBT) and 3,3,4,4,5,5,6,6,7, 7,8,8,9,9,10,10,10-heptadecafluoro-decane-1-thiol (HDFDT), were investigated. Modification was confirmed using attenuated total reflectance infrared spectroscopy; Raman mapping demonstrated that modification was homogenous on the macroscopic scale. The influence of fluorination on surface hydrophobicity was studied by contact angle analysis. The effect on microbial adherence was examined using Pseudomonas aeruginosa and Staphylococcus aureus.

KEY FINDINGS: The resultant changes in contact angle relative to control PVC ranged from -4 degrees to +14 degrees . In all cases, adherence of P. aeruginosa and S. aureus was significantly reduced relative to control PVC, with adherence levels ranging from 62% and 51% for TFTP-modified PVC to 32% and 7% for TFMTP-modified PVC.

CONCLUSIONS: These results demonstrate an important method in reducing the incidence of bacterial infection in PVC medical devices without compromising mechanical properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Adsorption behaviour of reactive dyes in fixed-bed adsorber was evaluated in this work. The characteristics of mass transfer zone (MTZ), where adsorption in column occurs, were affected by carbon bed depth and influent dye concentration. The working lifetime (t(x)) of MTZ, the height of mass transfer zone (HMTZ), the rate of mass transfer zone (RMTZ), and the column capacity at exhaustion (q(column)) were estimated for the removal of remazol reactive yellow and remazol reactive black by carbon adsorber. The results showed that column capacity calculated at 90% of column exhaustion was lower than carbon capacity obtained from equilibrium studies. This indicated that the capacity of activated carbon was not fully utilized in the fixed-bed adsorber. The bed-depth service time model (BDST) was applied for analysis of reactive yellow adsorption in the column. The adsorption capacity of reactive yellow calculated at 50% breakthrough point (No) was found to be 0.1 kg kg(-1) and this value is equivalent to about 14% of the available carbon capacity. The results of this study indicated the applicability of fixed-bed adsorber for removing remazol reactive yellow from solution. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Response time (RT) variability is a common finding in ADHD research. RT variability may reflect frontal cortex function and may be related to deficits in sustained attention. The existence of a sustained attention deficit in ADHD has been debated, largely because of inconsistent evidence of time-on-task effects. A fixed-sequence Sustained Attention to Response Task (SART) was given to 29 control, 39 unimpaired and 24 impaired-ADHD children (impairment defined by the number of commission errors). The response time data were analysed using the Fast Fourier Transform, to define the fast-frequency and slow-frequency contributions to overall response variability. The impaired-ADHD group progressively slowed in RT over the course of the 5.5 min task, as reflected in this group's greater slow-frequency variability. The fast-frequency trial-to-trial variability was also significantly greater, but did not differentially worsen over the course of the task. The higher error rates of the impaired-ADHD group did not become differentially greater over the length of the task. The progressive slowing in mean RT over the course of the task may relate to a deficit in arousal in the impaired-ADHD group. The consistently poor performance in fast-frequency variability and error rates may be due to difficulties in sustained attention that fluctuate on a trial-to-trial basis. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autism and Asperger's disorder (AD) are neurodevelopmental conditions that affect cognitive and social-communicative function. Using a movement-related potential (MRP) paradigm, we investigated the clinical and neurobiological issue of 'disorder separateness' versus 'disorder variance' in autism and AD. This paradigm has been used to assess basal ganglia/supplementary motor functioning in Parkinson's disease. Three groups (high functioning autism [HFA]: 16 males, 1 female; mean age 12y 5mo [SD 4y 4mo]; AD: 11 males, 2 females; mean age 13y 5mo [SD 3y 8mo]; comparison group: 13 males, 8 females; mean age 13y 10mo, [SD 3y 11 mo]) completed a cued motor task during electroencephalogram recording of MRPs. The HFA group showed reduced peak amplitude at Cz, indicating less activity over the supplementary motor area during movement preparation. Although an overall significant between-group effect was found for early slope and peak amplitude, subanalysis revealed that the group with AD did not differ significantly from either group. However, it is suggested that autism and AD may be dissociated on the basis of brain-behaviour correlations of IQ with specific neurobiological measures. The overlap between MRP traces for autism and Parkinson's disease suggests that the neurobiological wiring of motor functioning in autism may bypass the supplementary motor area/primary motor cortex pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adsorption behavior of C.I. Reactive Blue 2, C.I. Reactive Red 4, and C.I. Reactive Yellow 2 from aqueous solution onto activated carbon was investigated under various experimental conditions. The adsorption capacity of activated carbon for reactive dyes was found to be relatively high. At pH 7.0 and 298 K, the maximum adsorption capacity for C.I. Reactive Blue 2, C.I. Reactive Yellow 2 and C.I. Reactive Red 4 dyes was found to be 0.27, 0.24, and 0.11 mmol/g, respectively. The shape of the adsorption isotherms indicated an L2-type isotherm according to the Giles and Smith classification. The experimental adsorption data showed good correlation with the Langmuir and Ferundlich isotherm models. Further analysis indicated that the formation of a complete monolayer was not achieved, with the fraction of surface coverage found to be 0.45, 0.42, and 0.22 for C.I. Reactive Blue 2, C.I. Reactive Yellow 2 and C.I. Reactive Red 4 dyes, respectively. Experimental data indicated that the adsorption capacity of activated carbon for the dyes was higher in acidic rather than in basic solutions, and further indicated that the removal of dye increased with increase in the ionic strength of solution, this was attributed to aggregation of reactive dyes in solution. Thermodynamic studies indicated that the adsorption of reactive dyes onto activated carbon was an endothermic process. The adsorption enthalpy (?H) for C.I. Reactive Blue 2 and C.I. Reactive Yellow 2 dyes were calculated at 42.2 and 36.2 kJ/mol, respectively. The negative values of free energy (?G) determined for these systems indicated that adsorption of reactive dyes was spontaneous at the temperatures under investigation (298-328 K). © 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron attachment to NCCCCN, dicyanoacetylene (2-butynedinitrile), has been observed. Metastable parent anions, NCCCCN-*, with microsecond or longer lifetimes are formed close to 0 eV electron energy with a cross section of >= 0.25 angstrom(2). The stability of NCCCCN suggests that radiative attachment to NCCCCN and similar linear carbon chain molecules may be an important mechanism for the formation of negatively charged molecular ions in astrophysical environments. CCCN- and CN- fragment anions are formed at similar to 3 and similar to 6 eV.