133 resultados para hip replacement
Resumo:
Introduction: The prevalence of comorbidities in incident renal replacement therapy (RRT) patients changes with age and varies between ethnic groups. This study describes these associations and the independent effect of comorbidities on outcomes. Methods: Adult patients starting RRT between 2003 and 2008 in centres reporting to the UK Renal Registry (UKRR) with data on comorbidity (n ¼ 14,909) were included. The UKRR studied the association of comorbidity with patient demographics, treatment modality, haemoglobin, renal function at start of RRT and subsequent listing for kidney transplantation. The relationship between comorbidities and mortality at 90 days and one year after 90 days from start of RRT was explored using Cox regression. Results: Completeness of comorbidity data was 40.0% compared with 54.3% in 2003. Of patients with data, 53.8% had one or more comorbidities. Diabetes mellitus and ischaemic heart disease were the most common conditions seen in 30.1% and 22.7% of patients respectively. Current smoking was recorded for 14.5% of incident RRT patients in the 6-year period. Comorbidities became more common with increasing age in all ethnic groups although the difference between the 65–74 and 75+ age groups was not significant. Within each age group, South Asians and Blacks had lower rates of comorbidity, despite higher rates of diabetes mellitus. In multivariate survival analysis, malignancy and ischaemic/neuropathic ulcers were the strongest independent predictors of poor survival at 1 year after 90 days from the start of RRT. Conclusion: Differences in prevalence of comorbid illnesses in incident RRT patients may reflect variation in access to health care or competing risk prior to commencing treatment. At the same time, smoking rates remained high in this ‘at risk’ population. Further work on this and ways to improve comorbidity reporting should be priorities for 2010–11.
Resumo:
Introduction: The prevalence of 13 comorbid conditions and smoking status at the time of starting renal replacement therapy (RRT) in England, Wales and Northern Ireland are described. Methods: Adult patients starting RRT between 2002 and 2007 in centres reporting to the UK Renal Registry (UKRR) and with data on comorbidity (n¼13,293) were included. The association of comorbidity with patient demographics, treatment modality, haemoglobin, renal function at start of RRT and subsequent listing for kidney transplantation were studied. Association between comorbidities and mortality at 90 days and one year after 90 days from start of RRT was explored using Cox regression. Results: Completeness of data on comorbidity returned to the UKRR remained poor. Of patients with data, 52% had one or more comorbidities. Diabetes mellitus and ischaemic heart disease were the most common conditions seen in 28.9% and 22.5% of patients respectively. Comorbidities became more common with increasing age (up to the 65–74 age group), were more common amongst Whites and were associated with a lower likelihood of pre-emptive transplantation, a greater likelihood of starting on haemodialysis (rather than peritoneal dialysis) and a lower likelihood of being listed for kidney transplantation. In multivariable survival analysis, malignancy and ischaemic/neuropathic ulcers were the strongest predictors of poor survival at 1 year after 90 days from start of RRT. Conclusions: The majority of patients had at least one comorbid condition and comorbidity is an important predictor of early mortality on RRT.
Resumo:
Restoration of joint centre during total hip arthroplasty is critical. While computer-aided navigation can improve accuracy during total hip arthroplasty, its expense makes it inaccessible to the majority of surgeons. This article evaluates the use, in the laboratory, of a calliper with a simple computer application to measure changes in femoral head centres during total hip arthroplasty. The computer application was designed using Microsoft Excel and used calliper measurements taken pre- and post-femoral head resection to predict the change in head centre in terms of offset and vertical height between the femoral head and newly inserted prosthesis. Its accuracy was assessed using a coordinate measuring machine to compare changes in preoperative and post-operative head centre when simulating stem insertion on 10 sawbone femurs. A femoral stem with a modular neck was used, which meant nine possible head centre configurations were available for each femur, giving 90 results. The results show that using this technique during a simulated total hip arthroplasty, it was possible to restore femoral head centre to within 6?mm for offset (mean 1.67?±?1.16?mm) and vertical height (mean 2.14?±?1.51?mm). It is intended that this low-cost technique be extended to inform the surgeon of a best-fit solution in terms of neck length and neck type for a specific prosthesis.
Resumo:
The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.
Resumo:
Abstract:
Background: An estimated 30-60% of older
adults fall every year and about 1% of falls result in a hip fracture. Hip fracture is a serious and growing problem, with a 3-10 fold rise in worldwide incidence predicted by 2050 (Gullberg, et al 1997). Hip protectors are underwear with built in protection for the greater trochanter. They are designed to prevent hip fractures by dispersing or absorbing the force of a fall. Trials
published to 2001 were broadly supportive of
the effectiveness of hip protectors, and this
was reflected in a Cochrane review in 2000.
However, earlier trials were methodologically
flawed and subsequent trials have not demonstrated effectiveness. The most recent Cochrane review describes only a marginal benefit (Parker et al, 2005).
Review and Discussion: This presentation
evaluates the current evidence for the use
of hip protectors and discusses the use of
that evidence by manufacturers, suppliers,
professional groups and guideline developers.
Interestingly, despite the limitations of the
evidence base, most advice has been broadly
supportive. Reasons for this are proposed
and discussed in the context of a critique of
evidence-based healthcare. protectors. However, the available evidence can be used in different ways and for different purposes by those with an interest in promoting
the use of hip protectors. A conservative
approach is warranted, where, if we cannot
demonstrate that hip protectors work, we
presume that they do not. This presentation will be of use to practitioners wanting to evaluate the evidence base for hip protectors (and other recommended interventions) on behalf of clients. It will also be of interest to policy makers who must assess the claims made for health care technologies as part of the decisionmaking process.
Recommended reading:
Gullberg B, Johnell O, Kanis JA (1997) Worldwide
projections for hip fracture. Osteoporos
Int. 7(5):407-13 .
Parker MJ, Gillespie WJ, Gillespie LD (2005) Hip
protectors for preventing hip fractures in older
people. The Cochrane Database of Systematic
Reviews Issue 3. Art. No.: CD001255.pub3. DOI:
10.1002/14651858.CD001255.pub3.