135 resultados para durability
Resumo:
The durability of reinforced concrete structures depends, in the main, on the performance of the cover-zone concrete as it is this which protects the steel from the external environment. This paper focusses on the use of discretised electrical property measurements to study depth-related features during both the curing and post-curing period thereby allowing an integrated assessment of the protective properties of the cover region. In the current work, use is made of a small, multi-electrode array embedded within the surface 75mm of concrete specimens. Concretes were manufactured with different European cements (CEM) and water/binder ratios representing mixes which satisfied the minimum requirements for a range of environmental exposure classes including exposure to chlorides. Electrical resistance measurements were taken over a period in excess of 300 days which showed on-going hydration, pozzolanic reaction and pore-structure refinement; in addition, in the post-curing period, when exposed to a cyclic chloride ponding regime, measurements could be used to study the convective zone and ionic enrichment of the surface layer.
Resumo:
This paper gives an overview of the work carried out in a GARTEUR (Group for Aeronautical Research and Technology in Europe) program, under the chairmanship of the author, to develop and validate analytical and numerical methods to characterise real impact damage in composite structures, particularly those designed to sustain load in a postbuckled state, and to study the durability of bonded repairs. GARTEUR is an inter-governmental agreement between the seven European countries with the largest direct employment in the Aerospace industry, to mobilise scientific and technical knowledge between the member countries. A number of Action Groups have been launched, since GARTEUR’s inception in the early 1970s, to address specific technical issues of interest to the participating members. The research presented in this paper was performed under Action Group 28 with partners from ONERA, EADS-CCR (France), DLR, AIRBUS-Deutschland, EADS-M (Germany), CIRA (Italy), INTA (Spain), SICOMP, Saab, (Sweden), NLR (The Netherlands), QinetiQ, BAE Systems, Imperial College London and the University of Sheffield (United Kingdom). The Action Group tasks were divided into four Work Elements (WEs): WE1-Prediction and characterisation of impact damage, WE2- Postbuckling with delamination, WE3-Repair and WE4-Fatigue. This paper outlines the main developments and achievements within each Work Element.
Resumo:
This paper descirbes a simple test measuring the sorptivity (a measure of the absorption property if concrete) and the air and water permeability of concrete on site. Using this test, the decay of pressure is monitired for the air permeability test.whereas water penetrating into the concrete at a constant pressure of 0.01 bar and 1.5 bar are recorded for the sorptivity and the water permeability tests respectively. These tests are essentially non-destructive in nature and a skilled operator is not needed. It is possible to carry out a number of tests quickly and efficiently on site without prior planning. It has been found that statistically satisfactory results can be obtained from a mean of three tests. As the flow lines are largely concentrated within 40 mm from the surface, reasonably reliable results can be obtained by drying the surface even if the surface under test is initially wet.
Resumo:
This paper presents the results of an experimental investigation on compressive strength of unfired compressed brick obtained with coal combustion residues (CCRs) produced by the Niger Coal Society. Preliminary physical and optical (XRD and SEM) characterisation of coal slag, including lixiviation tests, have been carried out. Cement powder, lateritic clayey soil and sand have been chosen as stabilizing agents for bricks. 12 dosages have been tested and about 300 bricks have been produced with a hand-operated press. Results show uniaxial compressive strengths (UCSs) ranging from 4 MPa to 27 MPa for the highest cement stabilisation ratio. UCS higher than 7.5 MPa have been observed for stabilisation with 20% of laterite +10% cement after 45 days of curing. Obtained bricks showed good mechanical resistance and low weight. No health threat has been detected for the obtained samples. Study developments are oriented towards the analysis of Pozzolanic properties of CCRs, properties of hydrated lime stabilisation, thermal properties and durability assessment.© 2012 Elsevier Ltd. All rights reserved.
Resumo:
The current study monitors both the short- and long-term hydration characteristics of concrete using discretized conductivity measurements from initial gauging, through setting and hardening, the latter comprising both the curing and post-curing periods. In particular, attention is directed to the near-surface concrete as it is this zone which protects the steel from the external environment and has a major influence on durability, performance and service-life. A wide range of concrete mixes is studied comprising both plain Portland cement concretes and concretes containing fly-ash and ground granulated blast furnace slag. The parameter normalised conductivity was used to identify four distinct stages in the hydration process and highlight the influence of supplementary cementitious materials (SCM) on hydration and hydration kinetics. A relationship has been presented to account for the temporal decrease in conductivity, post 10-days hydration. The testing procedure and methodology presented lend itself to in-situ monitoring of reinforced concrete structures. (c) 2013 Elsevier Ltd. All rights reserved.
Resumo:
Plastic wastes, and particularly plastic bags and sachets, are a major concern for urban and rural environment in African countries. In the last years some actions have been started for the plastic recycling like the artisanal production of paving blocks with melted plastic bags and sand, albeit with differences in production processes. Nevertheless, the environmental and economic impact of such activities is still to be confirmed. The aim of this study is to propose a methodology for assessing and comparing the environmental and energetic performances of artisanal methods, and for defining the overall quality of the produced blocks. This methodology has been shaped through the analysis of
production processes operated by artisans/small enterprises in West Africa and through physic-mechanical tests on the blocks. A questionnaire which allows an insight into the process and on the product has been developed and tested over five processes. Results show that a high input energy level is observed through all the processes, while considerable savings of energy could be achieved. Moreover, tests results confirmed the importance of the utilised plastic concerning thermal dilatation, mechanical resistance at higher temperature and cooling-shrinkage effects. In conclusion, doubts remain about the technical and environmental effectiveness of the sampled experiences, durability of the products and sustainability of this approach. Nevertheless, being the collection and recycling of plastic wastes a potential income generation activity for marginalised social groups in urban environment, a process optimisation could improve the impact of blocks production. Alternative recycling activities should also be considered.
Resumo:
While on site measurement of air permeability provides a useful approach for assessing the likely long term durability of concrete structures, no existing test method is capable of effectively determining the relative permeability of high performance concrete (HPC). Lack of instrument sensitivity and the influence of concrete moisture are proposed as two key reasons for this phenomenon. With limited systematic research carried out in this area to date, the aim if this study was to investigate the influence of instrument sensitivity and moisture condition on air permeability measurements for both normal concrete and HPC. To achieve a range of moisture conditions, samples were dried initially for between one and 5 weeks and then sealed in polythene sheeting and stored in an oven at 50 C to internally distribute moisture evenly. Moisture distribution was determined throughout using relative humidity probe and electrical resistance measurements. Concrete air permeability was subsequently measured using standardised air permeability (Autoclam) and water penetration (BS EN: 12390-8) tests to assess differences between the HPCs tested in this study. It was found that for both normal and high performance concrete, the influence of moisture on Autoclam air permeability results could be eliminated by pre-drying (50 ± 1 C, RH 35%) specimens for 3 weeks. While drying for 5 weeks alone was found not to result in uniform internal moisture distributions, this state was achieved by exposing specimens to a further 3 weeks of sealed pre-conditioning at 50 ± 1 C. While the Autoclam test was not able to accurately identify relative HPC quality due to low sensitivity at associated performance levels, an effective preconditioning procedure to obtain reliable air permeability of HPC concretes was identified. © 2013 The Authors