110 resultados para Porcelain, Chinese


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study associations between strabismus and alcohol use, anxiety, and depression among 10- to 17-year-old children in Guangdong, southern China. Design: Cross-sectional, population-based study. Methods: Among 7537 children aged 6-17 years from 9 randomly selected primary and middle schools, ocular alignment was assessed with the Hirschberg light reflex, cover-uncover testing, and alternate cover testing at distance (6 m) and near (40 cm). Additionally, 4000 children (53.1%) aged 10+ years received self-administered questionnaires containing screening questions on alcohol use, anxiety, and depression. Results: Examinations were completed on 7464 of 7537 subjects (99.0%), including 3928 boys (52.6%), with a mean age of 11.1 ± 1.8 years. The prevalence of any strabismus, including exotropia (2.7%), esotropia (0.2%), and intermittent exotropia (3.9%), was 6.8%. Strabismus was more prevalent in urban students (7.3%) and female subjects (7.4%) compared to rural students (6.0%) and male subjects (6.2%) (all P <.05). In multivariate regression models, any strabismus was associated with older age and rural vs urban residence. Among 3903 children (97.6%) answering questionnaires, history of alcohol use (62.3% vs 36.3%) and positive screening responses for depression (26.0% vs 11.6%) and anxiety (10.3% vs 4.9%) were significantly (P <.01 for all) more common among children with strabismus. Conclusion: These Chinese children with strabismus had a significantly higher prevalence of alcohol use and possible markers of emotional problems than children without strabismus. Further research should focus on the appropriateness of classifying surgical treatment for strabismus as "cosmetic" (ineligible for reimbursement) under China's rural health insurance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the demographics and distribution of corneal astigmatism before cataract surgery in Chinese patients. Setting: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Clinic-based cross-sectional study. Methods: From July 2009 to May 2011, preoperative bilateral partial coherence interferometry (IOLMaster) was performed in consecutive patients having cataract surgery. Patient demographics and keratometric data were recorded. Results: The mean age of the 2849 patients (4831 eyes) was 70.56 years ± 9.55 (SD); there was a predominance of women patients (64.0%). The mean axial length was 23.58 ± 1.13 mm. The mean corneal astigmatism in this cohort was 1.01 D (range 0.05 to 6.59 D). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 25.1% of eyes, against the rule (ATR) in 58.2% of eyes, and oblique in 16.7% of eyes. The mean steep keratometry measurement was 44.76 ± 1.56 D. Against-the-rule astigmatism increased significantly with older age. Conclusions: Corneal astigmatism largely fell between 0.25 D and 1.25 D in these predominantly elderly female Chinese patients, and ATR astigmatism increased with age. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Primary angle-closure glaucoma (PACG) is more prevalent among Chinese than whites. The authors tested the hypothesis that Chinese have shallower anterior chambers than do whites, a factor that may be related to PACG prevalence. METHODS: The authors compared anterior chamber depth, axial length, radius of corneal curvature, and refractive error among 531 Chinese, 170 whites, and 188 blacks older than 40 years of age using the same model of instruments and identical technique. RESULTS: Mean anterior chamber depth and axial length did not differ significantly for the three groups. Whites had a significantly higher prevalence of hyperopia > 2 diopters than did Chinese. Radius of corneal curvature was significantly smaller among Chinese than whites or blacks. CONCLUSIONS: These results suggest that Chinese do not differ on a population basis from other ethnic groups in many of the biometric risk factors known to be of importance for PACG. It will be necessary to identify other ocular biometric parameters to explain the excess burden of PACG among Chinese, which may improve the effectiveness of screening for this disease in all populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the association between corneal hysteresis and axial length/refractive error among rural Chinese secondary school children. DESIGN: Cross-sectional cohort study. METHODS: Refractive error (cycloplegic auto-refraction with subjective refinement), central corneal thickness (CCT) and axial length (ultrasonic measurement), intraocular pressure (IOP), and corneal hysteresis (Reichert Ocular Response Analyzer) were measured on a rural school-based cohort of children. RESULTS: Among 1,233 examined children, the mean age was 14.7 +/- 0.8 years and 699 (56.7%) were girls. The mean spherical equivalent (n = 1,232) was -2.2 +/- 1.6 diopters (D), axial length (n = 643) was 23.7 +/- 1.1 mm, corneal hysteresis (n = 1,153) was 10.7 +/- 1.6 mm Hg, IOP (n = 1,153) was 17.0 +/- 3.4 mm Hg, and CCT (n = 1,226) was 553 +/- 33 microns. In linear regression models, longer axial length was significantly (P < .001 for both) associated with lower corneal hysteresis and higher IOP. Hysteresis in this population was significantly (P < .001) lower than has previously been reported for normal White children (n = 42, 12.3 +/- 1.3 mm Hg), when adjusting for age and gender. This difference did not appear to depend on differences in axial length between the populations, as it persists when only Chinese children with normal uncorrected vision are included. CONCLUSIONS: Prospective studies will be needed to determine if low hysteresis places eyes at risk for axial elongation secondary or if primary elongation results in lower hysteresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. METHODS: Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. RESULTS: Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (< or = 6/12 in the better eye) was 41.2%, 19.3%, and 0.5%, respectively. Myopia < -0.5, < -2.0, and < -6.0 D in both eyes was present in 62.3%, 31.1%, and 1.9% of the subjects, respectively. Among the children with visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P < 0.001) more presenting visual disability and myopia < -2.0 D than did the boys. More myopic refractive error was associated with worse self-reported visual function (ANOVA trend test, P < 0.001). CONCLUSIONS: Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study spectacle wear among rural Chinese children. METHODS: Visual acuity, refraction, spectacle wear, and visual function were measured. RESULTS: Among 1892 subjects (84.7% of the sample), the mean (SD) age was 14.7 (0.8) years. Among 948 children (50.1%) potentially benefiting from spectacle wear, 368 (38.8%) did not own them. Among 580 children owning spectacles, 17.9% did not wear them at school. Among 476 children wearing spectacles, 25.0% had prescriptions that could not improve their visual acuity to better than 6/12. Therefore, 62.3% (591 of 948) of children needing spectacles did not benefit from appropriate correction. Children not owning and not wearing spectacles had better self-reported visual function but worse visual acuity at initial examination than children wearing spectacles and had a mean (SD) refractive error of -2.06 (1.15) diopter (D) and -2.78 (1.32) D, respectively. Girls (P < .001) and older children (P = .03) were more likely to be wearing their spectacles. A common reason for nonwear (17.0%) was the belief that spectacles weaken the eyes. Among children without spectacles, 79.3% said their families would pay for them (mean, US $15). CONCLUSIONS: Although half of the children could benefit from spectacle wear, 62.3% were not wearing appropriate correction. These children have significant uncorrected refractive errors. There is potential to support programs through spectacle sales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the effect of myopia and spectacle wear on bicycle-related injuries in rural Chinese students. Myopia is common among Chinese students but few studies have examined its effect on daily activities. METHODS: Data on visual acuity, refractive error, current spectacle wear, and history of bicycle use and accidents during the past 3 years were sought from 1891 students undergoing eye examinations in rural Guangdong province. RESULTS: Refractive and accident data were available for 1539 participants (81.3%), among whom the mean age was 14.6 years, 52.5% were girls, 26.8% wore glasses, and 12.9% had myopia of less than -4 diopters in both eyes. More than 90% relied on bicycles to get to school daily. A total of 2931 accidents were reported by 423 participants, with 68 requiring medical attention. Male sex (odds ratio, 1.55; P < .001) and spectacle wear (odds ratio, 1.38; P = .04) were associated with a higher risk of accident, but habitual visual acuity and myopia were unassociated with the crash risk, after adjusting for age, sex, time spent riding, and risky riding behaviors. CONCLUSION: These results may be consistent with data on motor vehicle accidents implicating peripheral vision (potentially compromised by spectacle wear) more strongly than central visual acuity in mediating crash risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the hypothesis that changes in nutritional status could be partly responsible for observed increases in myopia prevalence among Chinese children. DESIGN: Cross-sectional cohort study. METHODS: Rural Chinese secondary school children participating in a study of interventions to promote spectacle use were randomly sampled (20% of children with uncorrected vision >6/12 bilaterally, and 100% of remaining children) and underwent cycloplegic refraction with subjective refinement and measurement of height and weight. Stunting was defined according to the World Health Organization standard population. RESULTS: Among 3226 children in the sample, 2905 (90.0%) took part. Among 1477 children undergoing refraction, 1371 (92.8%) had height and weight measurements. These children had a mean age of 14.5 +/- 1.4 years, 59.8% were girls, and mean spherical equivalent refraction was -1.93 +/- 1.82 diopters. Stunting was present in 87 children (6.4%). While height was inversely associated with refractive error (RE) (taller children were more myopic) among boys (r = -0.147, P = .001), this disappeared when adjusting for age, and no such association was observed among girls. Neither girls nor boys with stunting differed significantly in refraction from children without stunting, and neither stunting nor height was associated with RE when adjusting for age, height, and parental education. The power of this study to have detected a 0.75 diopters difference in RE between children with and without stunting was 0.96. CONCLUSION: Results from this cross-sectional study are not consistent with the hypothesis that nutritional status is a determinant of RE in this setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: China is urbanizing rapidly, and the prevalence of myopia is high. This study was conducted to identify the reasons for observed differences in the prevalence of myopia among urban versus rural Chinese children. METHODS: All children with uncorrected acuity of 6/12 or worse and a 50% random sample of children with vision better than 6/12 at all secondary schools in mixed rural-urban Liangying Township, Guangdong, underwent cycloplegic refraction, and provided data on age, gender, parental education, weekly near work and time outdoors, and urban development level of respondents' neighborhoods (12-item questionnaire). Population density of 32 villages and urban zones in Liangying was calculated from census figures (mean population density, 217 persons/km(2); range, 94-957; mean for Guangdong, 486). RESULTS: Among 5844 eligible children, 4612 (78.9%) had parental consent and completed examinations; 2957 were refracted per protocol, and 2480 (83.9%) of these had questionnaire data. Those with completed examinations were more likely to be girls (P < 0.001), and questionnaire respondents were more myopic (P = 0.02), but otherwise did not differ significantly from nonrespondents. In multivariate models, older age (P < 0.001), more near work (P = 0.02), and higher population density (P = 0.003), but not development index, parental education, or time outdoors were significantly associated with more myopic refractive error. CONCLUSIONS: Higher population density appears to be associated with myopia risk, independent of academic activity, time spent outdoors, familial educational level, or economic development, factors that have been thought to explain higher myopia prevalence among urban children. Mechanisms for this apparent association should be sought.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the effectiveness of diode laser trans-scleral cyclophotocoagulation (TSCPC) on intraocular pressure (IOP) in nine patients having raised IOP following use of silicone oil (SO) for retinal detachment (RD) surgery in a retrospective observational case series. Diode laser TSCPC was applied at a power setting of 1.75 to 2.5 watts, for two sec with a maximum of 30 applications. The patients were followed up for 40 to 312 weeks. The mean pre-laser IOP was 32.06 mm Hg (SD 7.32). The mean post-laser IOP at one month, three months and six months was 17.89 mm Hg (SD 8.23), 21.89 mm Hg (SD 8.16) and 21.67 mm Hg (SD 7.55) respectively. The final IOP (at the last follow-up) was 19.56 mm Hg (SD 7.85) (P=0.021). Seven of them had undergone SO removal. In our observation, effectiveness of TSCPC in long-term control of SO-induced ocular hypertension was limited as compared to short-term control of IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Low corneal hysteresis is associated with longer axial length in Chinese secondary school children. The authors sought to explore this association in primary school children. METHODS: LogMAR presenting visual acuity, cycloplegic refractive error, ocular biometry, central corneal thickness (CCT), and corneal hysteresis (CH) was assessed for children in grades 1 to 3 at an academically competitive urban school in Shantou, China. RESULTS: Among 872 eligible children (mean age, 8.6 ± 2.1 years), 651 (74.7%) completed the examination. Among 1299 examined eyes, 111 (8.5%) had uncorrected vision ≤6/12. Mean spherical equivalent refractive error for all eyes was +0.26 ± 1.41 D, and axial length (AL) was 22.7 ± 0.90 mm. CH for the lowest (mean AL, 21.7 ± 0.39 mm), two middle (mean AL, 22.4 ± 0.15 and 22.9 ± 0.15 mm), and highest quartiles (mean AL, 23.7 ± 0.74 mm) of AL were 10.6 ± 2.1 mm Hg, 10.4 ± 2.1 mm Hg, 10.3 ± 2.3 mm Hg, and 10.2 ± 2.3 mm Hg respectively (age- and gender-adjusted Pearson's correlation coefficient r = -0.052; P = 0.001). In generalized estimating equation models adjusting for age, gender, and CCT, lower CH was significantly associated with longer AL (P < 0.001) and more myopic refractive error (P = 0.001). CONCLUSIONS: CH measurement is practical in young children because this is when myopia undergoes its most rapid progression. Prospective follow-up of this cohort at high risk for myopia is under way to determine whether low CH is predictive, or a consequence, of long AL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.