284 resultados para Equipment testing
Resumo:
The study examined the extent to which variations in health-specific self-efficacy could affect general self-efficacy. In a repeated measures design, 300 participants were administered an efficacy questionnaire, before and after an alleged news report, aimed at increasing or decreasing self-efficacy over genetic-testing decision making. The results found that self-efficacy over testing was significantly reduced after reading the negative news report in those participants who felt personal efficacy over testing decisions was important. Levels of general self-efficacy were also significantly decreased. The findings suggest that being denied control over a specific area of self-efficacy can have a wider impact, with a lack of perceived efficacy over testing decision making adversely impacting on levels of general well-being. The wider implications of this generalization effect and the processes involved in efficacy generalization are discussed.
Resumo:
Polypropylene (PP), a semi-crystalline material, is typically solid phase thermoformed at temperatures associated with crystalline melting, generally in the 150° to 160°Celsius range. In this very narrow thermoforming window the mechanical properties of the material rapidly decline with increasing temperature and these large changes in properties make Polypropylene one of the more difficult materials to process by thermoforming. Measurement of the deformation behaviour of a material under processing conditions is particularly important for accurate numerical modelling of thermoforming processes. This paper presents the findings of a study into the physical behaviour of industrial thermoforming grades of Polypropylene. Practical tests were performed using custom built materials testing machines and thermoforming equipment at Queen′s University Belfast. Numerical simulations of these processes were constructed to replicate thermoforming conditions using industry standard Finite Element Analysis software, namely ABAQUS and custom built user material model subroutines. Several variant constitutive models were used to represent the behaviour of the Polypropylene materials during processing. This included a range of phenomenological, rheological and blended constitutive models. The paper discusses approaches to modelling industrial plug-assisted thermoforming operations using Finite Element Analysis techniques and the range of material models constructed and investigated. It directly compares practical results to numerical predictions. The paper culminates discussing the learning points from using Finite Element Methods to simulate the plug-assisted thermoforming of Polypropylene, which presents complex contact, thermal, friction and material modelling challenges. The paper makes recommendations as to the relative importance of these inputs in general terms with regard to correlating to experimentally gathered data. The paper also presents recommendations as to the approaches to be taken to secure simulation predictions of improved accuracy.
Resumo:
In a previous article in this journal, Daniel Kelly, Steven Stich, Kevin Haley, Serena Eng and Dan Fessler report data that, according to them, foster scepticism about an association between harm and morality existent in the Turiel tradition (Kelly et al., 2007). This article challenges their interpretation of the data. It does so by explicating some methodological problems in the Turiel tradition that Kelly et al. themselves in a way inherit and by drawing on new evidence coming from a partial replication of their research.
Resumo:
The Advanced JAX (TM) Bone Void Filler System (AJBVFS) is a novel bone graft material manufactured by Smith and Nephew Orthopaedics Ltd. and comprises beta tri-calcium phosphate granules with carboxymethylcellulose (CMC) gel as a handling agent. This study investigated the potential, in vitro, of the AJBVFS to function as a delivery system for cell therapy to enhance healing of bone defects. The attachment of rabbit bone marrow stromal cells (rbBMSCs), human BMSCs (hBMSCs) and human bone-derived cells (hBDCs) to JAX (TM) granules and the effect of CMC gel on cell proliferation and differentiation were investigated. There were slight species differences in the number and morphology of cells attached on the JAX (TM) granules with less rbBMSC attachment than human. All cells tolerated the presence of CMC gel and a reduction in cell number was only seen after longer exposure to higher gel concentrations. Low concentrations of CMC gel enhanced proliferation, alkaline phosphatase (ALP) expression and ALP activity in human cells but had no effect on rbBMSC. This study suggests that AJBVFS is an appropriate scaffold for the delivery of osteogenic cells and the addition of CMC gel as a handling agent promotes osteogenic proliferation and differentiation and is therefore likely to encourage bone healing.
Resumo:
This study evaluated a modification of the rat-pin model to enable testing of bone substitute materials. The model was characterized using the ceramic, beta-tricalcium phosphate (betaTCP) as a filler.
Resumo:
Background: Recent research has questioned the reliability and validity of the Nursing Work Index-Revised (NWI-R) instrument, raising the possibility that managers reconfiguring hospitals in line with the factors derived from the NWI-R may be misdirecting resources.
Testing the stability of the benefit transfer function for discrete choice contingent valuation data
Resumo:
This paper examines the stability of the benefit transfer function across 42 recreational forests in the British Isles. A working definition of reliable function transfer is Put forward, and a suitable statistical test is provided. A novel split sample method is used to test the sensitivity of the models' log-likelihood values to the removal of contingent valuation (CV) responses collected at individual forest sites, We find that a stable function improves Our measure of transfer reliability, but not by much. We conclude that, in empirical Studies on transferability, considerations of function stability are secondary to the availability and quality of site attribute data. Modellers' can study the advantages of transfer function stability vis-a-vis the value of additional information on recreation site attributes. (c) 2008 Elsevier GmbH. All rights reserved.
Resumo:
This paper investigates the performance of the tests proposed by Hadri and by Hadri and Larsson for testing for stationarity in heterogeneous panel data under model misspecification. The panel tests are based on the well known KPSS test (cf. Kwiatkowski et al.) which considers two models: stationarity around a deterministic level and stationarity around a deterministic trend. There is no study, as far as we know, on the statistical properties of the test when the wrong model is used. We also consider the case of the simultaneous presence of the two types of models in a panel. We employ two asymptotics: joint asymptotic, T, N -> infinity simultaneously, and T fixed and N allowed to grow indefinitely. We use Monte Carlo experiments to investigate the effects of misspecification in sample sizes usually used in practice. The results indicate that the assumption that T is fixed rather than asymptotic leads to tests that have less size distortions, particularly for relatively small T with large N panels (micro-panels) than the tests derived under the joint asymptotics. We also find that choosing a deterministic trend when a deterministic level is true does not significantly affect the properties of the test. But, choosing a deterministic level when a deterministic trend is true leads to extreme over-rejections. Therefore, when unsure about which model has generated the data, it is suggested to use the model with a trend. We also propose a new statistic for testing for stationarity in mixed panel data where the mixture is known. The performance of this new test is very good for both cases of T asymptotic and T fixed. The statistic for T asymptotic is slightly undersized when T is very small (