175 resultados para Equipment failure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pharmacokinetics of flosequinan were studied in a group of 18 patients with chronic cardiac failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic heart failure (CHF) is often associated with impaired renal function due to hypoperfusion. Such patients are very sensitive to changes in renal perfusion pressure, and may develop acute tubular necrosis if the pressure falls too far. The situation is complicated by the use of diuretics, ACE inhibitors and spironolactone, all of which may affect renal function and potassium balance. Chronic renal failure (CRF) may also be associated with fluid overload. Anaemia and hypertension in CRF contribute to the development of left ventricular hypertrophy (LVH), which carries a poor prognosis, so correction of these factors is important.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transplantation of hepatocytes or hepatocyte-like cells of extrahepatic origin is a promising strategy for treatment of acute and chronic liver failure. We examined possible utility of hepatocyte-like cells induced from bone marrow cells for such a purpose. Clonal cell lines were established from the bone marrow of two different rat strains. One of these cell lines, rBM25/S3 cells, grew rapidly (doubling time, approximately 24 hours) without any appreciable changes in cell properties for at least 300 population doubling levels over a period of 300 days, keeping normal diploid karyotype. The cells expressed CD29, CD44, CD49b, CD90, vimentin, and fibronectin but not CD45, indicating that they are of mesenchymal cell origin. When plated on Matrigel with hepatocyte growth factor and fibroblast growth factor-4, the cells efficiently differentiated into hepatocyte-like cells that expressed albumin, cytochrome P450 (CYP) 1A1, CYP1A2, glucose 6-phosphatase, tryptophane-2,3-dioxygenase, tyrosine aminotransferase, hepatocyte nuclear factor (HNF)1 alpha, and HNF4alpha. Intrasplenic transplantation of the differentiated cells prevented fatal liver failure in 90%-hepatectomized rats. In conclusion, a clonal stem cell line derived from adult rat bone marrow could differentiate into hepatocyte-like cells, and transplantation of the differentiated cells could prevent fatal liver failure in 90%-hepatectomized rats. The present results indicate a promising strategy for treating human fatal liver diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the use of a compliant web design for improved damage tolerance in stiffener run-outs is investigated. Firstly, a numerical study that incorporates the possibility of debonding and delamination (using VCCT) is used to select a favourable compliant run-out configuration. Then, three different configurations are compared to establish the merits of the compliant design: a baseline configuration, a configuration with optimised tapering and the selected compliant configuration. The performance of these configurations, in terms of strength and damage tolerance, was compared numerically using a parametric finite element analysis. The energy release rates for debonding and delamination, for different crack lengths across the specimen width, were used for this comparison. The three configurations were subsequently manufactured and tested. In order to monitor the failure process, acoustic emission (AE) equipment was used and proved valuable in the detection and analysis of failure. The predicted failure loads, based on the energy release rates, showed good agreement with the experiments, particularly when the distribution of energy release rate across the width of the specimen was taken into account. As predicted numerically, the compliant configuration failed by debonding and showed improved damage tolerance compared to the baseline and tapered stiffener run-outs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major concern in stiffener run-out regions, where the stiffener is terminated due to a cut-out, intersecting rib, or some other structural feature which interrupts the load path, is the relatively weak skin–stiffener interface in the absence of mechanical fasteners. More damage tolerant stiffener run-outs are clearly required and these are investigated in this paper. Using a parametric finite element analysis, the run-out region was optimised for stable debonding crack growth. The modified run-out, as well as a baseline configuration, were manufactured and tested. Damage initiation and propagation was investigated in detail using state-of-the-art monitoring equipment including Acoustic Emission and Digital Image Correlation. As expected, the baseline configuration failed catastrophically. The modified run-out showed improved crack-growth stability, but subsequent delamination failure in the stiffener promptly led to catastrophic failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a three-dimensional continuum damage mechanics-based material model which was implemented in an implicit finite element code to simulate the progressive intralaminar degradation of fibre reinforced laminates. The damage model is based on ply failure mechanisms and uses seven damage variables assigned to tensile, compressive and shear damage at a ply level. Non-linear behaviour and irreversibility were taken into account and modelled. Some issues on the numerical implementation of the damage model are discussed and solutions proposed. Applications of the methodology are presented in Part II

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A three-dimensional continuum damage mechanics-based material model was implemented in an implicit Finite Element code to simulate the progressive intralaminar degradation of fibre reinforced laminates based on ply failure mechanisms. This paper presents some structural applications of the progressive failure model implemented. The focus is on the non-linear response of the shear failure mode and its interaction with other failure modes. Structural applications of the damage model show that the proposed model is able to reproduce failure loads and patterns observed experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a 3-D failure model for predicting the dynamic material response of composite laminates under impact loading. The formulation is based on the Continuum Damage Mechanics (CDM) approach and enables the control of the energy dissipation associated with each failure mode regardless of mesh refinement and fracture plane orientation. Internal thermodynamically irreversible damage variables were defined in order to quantify damage concentration associated with each possible failure mode and predict the gradual stiffness reduction during the impact damage process. The material model has been implemented into LS-DYNA explicit finite element code within solid elements and it has proven to be capable of reproducing experimental results with good accuracy in terms of static/dynamic responses, absorbed energy and extent of damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-scale 34 m composite wind turbine blade was tested to failure under flap-wise loading. Local displacement measurement equipment was developed and displacements were recorded throughout the loading history.

Ovalization of the load carrying box girder was measured in the full-scale test and simulated in non-linear FE-calculations. The nonlinear Brazier effect is characterized by a crushing pressure which causes the ovalization. To capture this effect, non-linear FE-analyses at different scales were employed. A global non-linear FE-model of the entire blade was prepared and the boundaries to a more detailed sub-model were extracted. The FE-model was calibrated based on full-scale test measurements.

Local displacement measurements helped identify the location of failure initiation which lead to catastrophic failure. Comparisons between measurements and FE-simulations showed that delamination of the outer skin was the initial failure mechanism followed by delamnination buckling which then led to collapse. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent efforts towards the development of the next generation of large civil and military transport aircraft within the European community have provided new impetus for investigating the potential use of composite material in the primary structure. One concern in this development is the vulnerability of co-cured stiffened structures to through-thickness stresses at the skin-stiffener interfaces particularly in stiffener runout regions. These regions are an inevitable consequence of the requirement to terminate stiffeners at cutouts, rib intersections or other structural features which interrupt the stiffener load path. In this respect, thickerskinned components are more vulnerable than thin-skinned ones. This work presents an experimental and numerical study of the failure of thick-sectioned stiffener runout specimens loaded in uniaxial compression. The experiments revealed that failure was initiated at the edge of the runout and propagated across the skin-stiffener interface. High frictional forces at the edge of the runout were also deduced from a fractographic analysis and it is postulated that these forces may enhance the fracture toughness of the specimens. Finite element analysis using an efficient thick-shell element and the Virtual Crack Closure Technique was able to qualitatively predict the crack growth characteristics for each specimen