153 resultados para Diagnostic attributes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the challenges of integrating an asthma disease management (DM) program into a primary care setting from the perspective of primary care practitioners. A second goal was to examine whether barriers differed between urban-based and nonurban-based practices. Using a qualitative design, data were gathered using focus groups in primary care pediatric practices. A purposeful sample included an equal number of urban and nonurban practices. Participants represented all levels in the practice setting. Important themes that emerged from the data were coded and categorized. A total of 151 individuals, including physicians, advanced practice clinicians, registered nurses, other medical staff, and nonmedical staff participated in 16 focus groups that included 8 urban and 8 nonurban practices. Content analyses identified 4 primary factors influencing the implementation of a DM program in a primary care setting. They were related to providers, the organization, patients, and characteristics of the DM program. This study illustrates the complexity of the primary care environment and the challenge of changing practice in these settings. The results of this study identified areas in a primary care setting that influence the adoption of a DM program. These findings can assist in identifying effective strategies to change clinical behavior in primary care practices. © 2008 Mary Ann Liebert, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the contribution of organizational factors to implementation of 3 asthma quality measures: enrollment in a disease management program, development of a written treatment plan, and prescription of severity-appropriate anti-inflammatory therapy. Study design: A total of 138 pediatric clinicians and 247 office staff in 13 urban clinics and 23 nonurban private practices completed questionnaires about their practice's organizational characteristics (eg, leadership, communication, perceived effectiveness, job satisfaction). Results: 94% of the clinicians and 92% of the office staff completed questionnaires. When adjusted for confounders, greater practice activity and perceived effectiveness in meeting family needs were associated with higher rates of enrollment in the Easy Breathing program, whereas higher scores for 3 organizational characteristics-communication timeliness, decision authority, and job satisfaction-were associated with both higher enrollment and a greater number of written treatment plans. None of the organizational characteristics was associated with greater use of anti-inflammatory therapy. Conclusions: Three organizational characteristics predicted 2 quality asthma measures: use of a disease management program and creation of a written asthma treatment plan. If these organizational characteristics were amenable to change, then our findings could help focus interventions in areas of effective and acceptable organizational change. © 2009 Mosby, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. © 2007 American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the diagnostic abilities of the standard bracketing strategy (BR) and a fast strategy, the tendency-oriented perimetry (TOP). Methods: Seventy-seven controls and 91 eyes from patients with glaucoma were analyzed with the strategies TOP and BR. Sensitivity (Se), specificity (Sp), the area under the receiver operating characteristic (ROC) curve (AC) and the optimum cutoff value (CO) were calculated for the visual field indices mean defect (MD), the square root of the loss variance (sLV) and the number of pathological points (NPP). Results: In the glaucoma group, the mean MD value using TOP and BR was 7.5 and 8.3 dB, respectively. The mean sLV value using TOP and BR was 5.0 and 5.3 dB, respectively. Indices provided by TOP had higher ROC values than the ones provided by BR. Using TOP, the index with the best diagnostic ability was sLV (Sp = 94.8, Se = 90.1, AC = 0.966, CO = 2.5 dB), followed by NPP and MD. Using BR, the best results were obtained for MD (Sp = 92.2, Se = 81.3, AC = 0.900, CO = 2.5 dB) followed by sLV and NPP. Conclusions: A fast strategy, TOP, had superior diagnostic ability than the standard BR. Although TOP provided lower LV values than BR, the diagnostic ability of this index was higher than that of the conventional strategy. Copyright © 2005 S. Karger AG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. Methods: The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. Results: A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Conclusion: Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We predicted that the probability of egg occurrence of salamander Salamandrina perspicillata depended on stream features and predation by native crayfish Austropotamobius fulcisianus and the introduced trout Salmo trutta. We assessed the presence of S. perspicillata at 54 sites within a natural reserve of southern Tuscany, Italy. Generalized linear models with binomial errors were constructed using egg presence/absence and altitude, stream mean size and slope, electrical conductivity, water pH and temperature, and a predation factor, defined according to the presence/absence of crayfish and trout. Some competing models also included an autocovariate term, which estimated how much the response variable at any one sampling point reflected response values at surrounding points. The resulting models were compared using Akaike's information criterion. Model selection led to a subset of 14 models with Delta AIC(c) <7 (i.e., models ranging from substantial support to considerably less support), and all but one of these included an effect of predation. Models with the autocovariate term had considerably more support than those without the term. According to multimodel inference, the presence of trout and crayfish reduced the probability of egg occurrence from a mean level of 0.90 (SE limits: 0.98-0.55) to 0.12 (SE limits: 0.34-0.04). The presence of crayfish alone had no detectable effects (SE limits: 0.86-0.39). The results suggest that introduced trout have a detrimental effect on the reproductive output of S. perspicillata and confirm the fundamental importance of distinguishing the roles of endogenous and exogenous forces that act on population distribution.