124 resultados para Dental Implants. Stomatitis. Periimplantitis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interprofessional education (IPE) should help to promote a team-based approach to professional practice but there are barriers to its implementation including professional identity. The aim of this study was to use a qualitative research methodology to explore dental and dental care professional (DCP) students' perceptions of professional roles and identities in the dental team. Data were collected by means of focus groups from a purposive sample of dental and DCP students and were audio recorded, transcribed and analysed using an explanatory framework. Five common themes emerged around the issue of professional roles and identity in the dental team. The results indicate that professional identity was an important factor in team development and was determined by direct responsibility for patient care and by the amount of clinical experience acquired. Professional identity within a team context was perceived as different from professional identity per se. Dental students were found to lack confidence in their role as team leaders which was related to their lack of knowledge of team roles, responsibilities and experience. The role of the dental technician was perceived as 'outside' the dental team due to lack of patient interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years there has seen an increased interest in refractive surgery for the correction of presbyopia. This can be attributed to a number of factors such as the increased demand from patients to have perfect vision without the need for glasses, spurred on by the success of high street refractive laser surgery. Also the World Health Organisation (WHO) estimated in 2005 that over a 1.04 billion people worldwide are affected by presbyopia (Holden et al. 2008). This vast number of people is valued as a potential market and is a huge enticement to the ophthalmic industry to try and develop devices and products to treat this condition. Recent advances in technology have renewed interest in the implantation of corneal inlays for surgical treatment of presbyopia. Dexl et al. (2011) suggest that the reason for this is the further development of biomaterial technology, advances in femtosecond laser and the need for a reversible presbyopic treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous titanium samples were manufactured using the 3D printing and sintering method in order to determine the effects of final sintering temperature on morphology and mechanical properties. Cylindrical samples were printed and split into groups according to a final sintering temperature (FST). Irregular geometry samples were also printed and split into groups according to their FST. The cylindrical samples were used to determine part shrinkage, in compressive tests to provide stress-strain data, in microCT scans to provide internal morphology data and for optical microscopy to determine surface morphology. All of the samples were used in microhardness testing to establish the hardness. Below 1100 C FST, shrinkage was in the region of 20% but increased to approximately 30% by a FST of 1300 C. Porosity varied from a maximum of approximately 65% at the surface to the region of 30% internally. Between 97 and 99% of the internal porosity is interconnected. Average pore size varied between 24 µm at the surface and 19 µm internally. Sample hardness increased to in excess of 300 HV0.05 with increasing FST while samples with an FST of below 1250 C produced an elastic-brittle stress/strain curve and samples above this displayed elastic-plastic behaviour. Yield strength increased significantly through the range of sintering temperatures while the Young's modulus remained fairly consistent. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endodontic lubricants, irrigating solutions and medicaments help reduce the microbial load within root canals. Primary and secondary cases involve different microbes. Each'solution'or combinations thereof could play a significant role but no detailed guidelines exist on their use. An audit was undertaken to compare current practice in Belfast Dental School to the others across the UK and Republic of Ireland (ROI). This audit highlighted three main differences between Belfast and other dental schools. Many other institutions utilized other irrigants besides sodium hypochlorite (NaOCl), different intracanal medicaments, including calcium hydroxide, and higher concentrations of NaOCl. Having gathered this information, we ask, 'Is there sufficient evidence to change the endodontic regime currently used at Belfast Dental School?'. Using the findings from the literature review (Part 1), we introduce new evidence-based protocols for primary and secondary cases for use in Belfast Dental School. Clinical Relevance: In the absence of detailed clinical guidelines on the use of endodontic lubricants, irrigants and medicaments in primary and secondary cases, it is important to be aware of current practice in UK and ROI dental schools where dentists and specialists are trained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate dental erosion among 12-14 year old Sudanese school children and evaluate the associated risk factors. Basic Research Design: Cross sectional survey in secondary schools in Khartoum city, Sudan. Method and Participants: A sample of 157 school children was obtained from both private and public schools. Erosion on the labial and palatal surfaces of maxillary incisors was measured by criterion based on the Smith and Knight Tooth Wear Index. Dietary intake and other related factors were assessed using a questionnaire. Results: The overall erosion prevalence in this group was 66.9%, of which 45.2% was mild and 21.7% was moderate erosion. A strong association was found between erosion and private schooling (higher socioeconomic groups), carbonated drinks, herbal hibiscus drink and traditional acidic food consumption. Conclusion: There was a high prevalence of dental erosion among Sudanese school children which was mild to moderate in severity and was strongly associated with acidic dietary intake © BASCD 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In situ forming (ISF) drug delivery implants have gained tremendous levels of interest over the last few decades. This is due to their wide range of biomedical applications such as in tissue engineering, cell encapsulation, microfluidics, bioengineering and drug delivery. Drug delivery implants forming upon injection has shown a range of advantages which include localized drug delivery, easy and less invasive application, sustained drug action, ability to tailor drug delivery, reduction in side effects associated with systemic delivery and also improved patient compliance and comfort. Different factors such as temperature, pH, ions, and exchange of solvents are involved in in situ implant formation. This review especially focuses on ISF implants that are formed through solvent induced phase inversion (SPI) technique. The article critically reviews and compares a wide range of polymers, solvents, and co-solvents that have been used in SPI implant preparation for control release of a range of drug molecules. Major drawback of SPI systems has been their high burst release. In this regard, the article exhaustively discusses factors that affect the burst release and different modification strategies that has been utilised to reduce the burst effect from these implants. Performance and controversial issues associated with the use of different biocompatible solvents in SPI systems is also discussed. Biodegradation, formulation stability, methods of characterisation and sterilisation techniques of SPI systems is comprehensively reviewed. Furthermore, the review also examines current SPI-based marketed products, their therapeutic application and associated clinical data. It also exemplifies the interest of multi-billion dollar pharma companies worldwide for further developments of SPI systems to a range of therapeutic applications. The authors believe that this will be the first review article that extensively investigate and discusses studies done to date on SPI systems. In so doing, this article will undoubtedly serve as an enlightening tool for the scientists working in the concerned area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract
INTRODUCTION:
Transient receptor potential (TRP) channels comprise a group of nonselective calcium-permeable cationic channels, which are polymodal sensors of environmental stimuli such as thermal changes and chemicals. TRPM8 and TRPA1 are cold-sensing TRP channels activated by moderate cooling and noxious cold temperatures, respectively. Both receptors have been identified in trigeminal ganglion neurones, and their expression in nonneuronal cells is now the focus of much interest. The aim of this study was to investigate the molecular and functional expression of TRPA1 and TRPM8 in dental pulp fibroblasts.
METHODS:
Human dental pulp fibroblasts were derived from healthy molar teeth. Gene and protein expression was determined by polymerase chain reaction and Western blotting. Cellular localization was investigated by immunohistochemistry, and TRP functionality was determined by Ca(2+) microfluorimetry.
RESULTS:
Polymerase chain reaction and Western blotting showed gene and protein expression of both TRPA1 and TRPM8 in fibroblast cells in culture. Immunohistochemistry studies showed that TRPA1 and TRPM8 immunoreactivity co-localized with the human fibroblast surface protein. In Ca(2+) microfluorimetry studies designed to determine the functionality of TRPA1 and TRPM8 in pulp fibroblasts, we showed increased intracellular calcium ([Ca(2+)](i)) in response to the TRPM8 agonist menthol, the TRPA1 agonist cinnamaldehyde, and to cool and noxious cold stimuli, respectively. The responses to agonists and thermal stimuli were blocked in the presence of specific TRPA1 and TRPM8 antagonists.
CONCLUSIONS:
Human dental pulp fibroblasts express TRPA1 and TRPM8 at the molecular, protein, and functional levels, indicating a possible role for fibroblasts in mediating cold responses in human teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this research is to use finite element analysis (FEA) to quantify the effect of the sample shape and the imperfections induced during the manufacturing process of samples on the bond strength and modes of failure of dental adhesive systems through microtensile test. Using the FEA prediction for individual parameters effect, estimation of expected variation and spread of the microtensile bond strength results for different sample geometries is made. Methods: The estimated stress distributions for three different sample shapes, hourglass, stick and dumbbell predicted by FEA are used to predict the strength for different fracture modes. Parameters such as the adhesive thickness, uneven interface of the adhesive and composite and dentin, misalignment of axis of loading, the existence of flaws such as induced cracks during shaping the samples or bubbles created during application of the adhesive are considered. Microtensile experiments are performed simultaneously to measure bond strength and modes of failure. These are compared with the FEA results. Results: The relative bonding strength and its standard deviation for the specimens with different geometries measured through the microtensile tests confirm the findings of the FEA. The hourglass shape samples show lower tensile bond strength and standard deviation compared to the stick and dumbbell shape samples. ANOVA analysis confirms no significant difference between dumbbell and stick geometry results, and major differences of these two geometries compared to hourglass shape measured values. Induced flaws in the adhesive and misalignment of the angle of application of load have significant effect on the microtensile bond strength. Using adhesive with higher modulus the differences between the bond strength of the three sample geometries increase. Significance: The result of the research clarifies the importance of the sample geometry chosen in measuring the bond strength. It quantifies the effect of the imperfections on the bond strength for each of the sample geometries through a systematic and all embracing study. The results explain the reasons of the large spread of the microtensile test results reported by various researchers working in different labs and the need for standardization of the test method and sample shape used in evaluation of the dentin-adhesive bonding system. © 2007 Academy of Dental Materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Pharmaceutical Journal, 6 September 2014, Vol 293, No 7826, online | URI: