97 resultados para Corneal opacity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM:

To describe the distribution of cataract subtypes present before surgery among a defined population of older, bilaterally pseudophakic individuals.

METHODS:

This was a cohort study of bilaterally pseudophakic individuals participating in the Salisbury Eye Evaluation (SEE), and their locally resident siblings. Subjects underwent slit lamp and retroillumination photography and grading using the Wilmer Cataract Grading System. For all individuals determined to be bilaterally pseudophakic, an attempt was made to determine for each eye the type(s) of cataract present before surgery, based on previous SEE photographs (for SEE participants) and/or medical records obtained from the operating ophthalmologist (for both SEE participants and their siblings).

RESULTS:

The mean age of 223 participants providing data in this study was 78.7 (SD 5.2) years, 19.3% of subjects were black and 60.1% female. The most common surgically removed cataract subtype in this population was pure nuclear (43.5%), followed by nuclear combined with posterior subcapsular cataract (PSC) (20.6%), and nuclear combined with cortical (13.9%); less common types were pure cortical (4.9%), pure PSC (4.5%), and PSC combined with cortical (2.7%). Factors such as sex and source of lens data (study photograph versus clinical record) did not significantly affect the distribution of lens opacity types, while PSC was significantly (p = 0.01) more common among younger people and nuclear cataract was significantly (p = 0.001) more common among white compared to black people.

CONCLUSION:

Epidemiological studies have suggested that the different subtypes of cataract are associated with different risk factors. As studies begin to identify new prevention strategies for cataract, it would appear likely that different strategies will be efficacious against different types of cataract. In this setting, it will be helpful to know which cataract types are most frequently associated with surgery. Among this older, majority white population, nuclear cataract showed a clear predominance among individuals having undergone surgery in both eyes. This may be contrasted with both clinic and population based studies of younger people, which have generally found PSC cataract to predominate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:

The purpose of this study was to report on Tsukamurella as a mimic of atypical mycobacterial infection.

METHODS:

We report a patient who had received repeated corneal grafts with culture-proven Tsukamurella keratitis.

RESULTS:

A slow-progressing corneal abscess that initially developed adjacent to a corneal stitch responded poorly to empiric antibiotic treatment. A preliminary culture report revealed fast-growing mycobacterial species. Treatment adjustments successfully controlled the disease. A final diagnosis of Tsukamurella was subsequently made on the basis of cultures.

CONCLUSIONS:

Tsukamurella exhibits laboratory similarities to mycobacteria and should be considered in the differential of atypical infection of the ocular surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE:

To compare the outcomes of cataract surgery performed with 3 incision size-dependent phacoemulsification groups (1.8, 2.2, and 3.0 mm).

DESIGN:

Prospective randomized comparative study.

METHODS:

One hundred twenty eyes of 120 patients with age-related cataract (grades 2 to 4) were categorized according to the Lens Opacities Classification System III. Eligible subjects were randomly assigned to 3 surgical groups using coaxial phacoemulsification through 3 clear corneal incision sizes (1.8, 2.2, and 3.0 mm). Different intraoperative and postoperative outcome measures were obtained, with corneal incision size and surgically induced astigmatism as the main clinical outcomes.

RESULTS:

There were no statistically significant differences in most of the intraoperative and postoperative outcome measures among the 3 groups. However, the mean cord length of the clear corneal incision was increased in each group after surgery. The mean maximal clear corneal incision thickness in the 1.8-mm group was significantly greater than for the other groups at 1 month. The mean surgically induced astigmatism in the 1.8- and 2.2-mm groups was significantly less than that in the 3.0-mm group after 1 month, without significant difference between the 1.8- and 2.2-mm groups.

CONCLUSIONS:

With appropriate equipment, smaller incisions may result in less astigmatism, but the particular system used will influence incision stress and wound integrity, and may thus limit the reduction in incision size and astigmatism that is achievable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The asymmetries observed in the line profiles of solar flares can provide important diagnostics of the properties and dynamics of the flaring atmosphere. In this paper the evolution of the Hα and Ca ii λ8542 lines are studied using high spatial, temporal, and spectral resolution ground-based observations of an M1.1 flare obtained with the Swedish 1 m Solar Telescope. The temporal evolution of the Hα line profiles from the flare kernel shows excess emission in the red wing (red asymmetry) before flare maximum and excess in the blue wing (blue asymmetry) after maximum. However, the Ca ii λ8542 line does not follow the same pattern, showing only a weak red asymmetry during the flare. RADYN simulations are used to synthesize spectral line profiles for the flaring atmosphere, and good agreement is found with the observations. We show that the red asymmetry observed in Hα is not necessarily associated with plasma downflows, and the blue asymmetry may not be related to plasma upflows. Indeed, we conclude that the steep velocity gradients in the flaring chromosphere modify the wavelength of the central reversal in the Hα line profile. The shift in the wavelength of maximum opacity to shorter and longer wavelengths generates the red and blue asymmetries, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The line intensity ratio method provides a nonintrusive diagnostic for the measurement of electron temperature in microwave-generated plasmas. For optically thin plasmas of low density, a line intensity method using He I lines can often be used, and is based on the fact that the electron impact excitation rate coefficients for helium singlet and triplet states are insensitive to electron density but differ as a function of the electron temperature. Line intensity measurements are presented from microwave-generated helium plasmas. Both steady-state corona and collision-radiative theoretical models are used to evaluate the ground and excited state populations. The line ratio versus electron temperature obtained from both of these methods are compared with the results from measurements. However, it is not possible to diagnose the electron temperature from the line ratios alone due to the presence of significant opacity and nonnegligible 1s2s S-3 metastable fraction in the plasma. (C) 2004 American Institute of Physics.