Resumo:
The reaction of 1-butylpyrrolidine with dimethyl carbonate to yield the ionic liquid precursor, 1-butyl-1-methylpyrrolidinium methylcarbonate, has been investigated under microwave heating conditions and the reaction parameters optimised to achieve 100% yield of the pyrrolidinium salt with no by-products in under 1 h. The reactions of tributylamine, trioctylphosphine, and 1-butylimidazole with dimethyl carbonate under comparable conditions have also been evaluated, yielding the corresponding methylcarbonate salts which can be used as intermediates for the preparation of halide-free ionic liquids without generating any undesirable salt wastes.
Resumo:
Experimental data are presented for liquid-liquid equilibria of mixtures of the room-temperature ionic liquid 1-ethyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl)imide ([C2MIM][NTf2]) with the three alcohols propan-1-ol, butan-1-ol, and pentan-1-ol and for the 1-butyl-3-methyl-imidazolium bis(trifluoromethylsulfonyl) imide ([C4MIM][NTf2]) with cyclohexanol and 1,2-hexanediol in the temperature range of 275 K to 345 K at ambient pressure. The synthetic method has been used. Cloud points at a given composition were observed by varying the temperature and using light scattering to detect the phase splitting. In addition, the influence of small amounts of water on the demixing temperatures of binary mixtures of [C2MIM][NTf2] and propan-1-ol, butan-1-ol, and pentan-1-ol was investigated.
Resumo:
beta-Agonists are among the most widely abused drugs in veterinary medicine for the illegal promotion of farm animal growth. An array of analytical procedures has been developed to detect the residues of these compounds in many biological materials. As the number of beta-agonist formulations increases, it has become increasingly difficult to devise screening techniques capable of detecting a broad spectrum of these residues in a single test. A dual immunoassay based on time-resolved fluorescence was developed that incorporated a monoclonal antibody raised to tertiary butyl amines and a polyclonal antibody to biphenolic beta-agonists. This assay was capable of detecting residues of a range of beta-agonists present in bovine urine without the need for sample extraction. The limits of detection of the assay ranged from 1 to 8.5 ng ml(-1) depending on the cross-reactivity of individual compounds with the antibodies employed in the procedure.
Resumo:
Densities and viscosities were measured as a function of temperature for six ionic liquids (1-butyl-3-methylimidazolium hexafluorophosphate, 1-butyl-3-methylimidazolium tetrafluoroborate, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, 1-ethyl-3-methylimidazolium ethylsulfate and butyltrimethylammonium bis(trifluoromethylsulfonyl)imide. The density and the viscosity were obtained using a vibrating tube densimeter from Anton Paar and a rheometer from Rheometrics Scientific at temperatures up to 393 K and 388 K with an accuracy of 10-3 g cm-3 and 1%, respectively. The effect of the presence of water on the measured values was also examined by studying both dried and water-saturated samples. A qualitative analysis of the evolution of density and viscosity with cation and anion chemical structures was performed. © The Royal Society of Chemistry 2006.
Resumo:
Experimental values for the solubility of carbon dioxide and hydrogen in three room temperature ionic liquids based on the same anion- (bistrifluoromethylsulfonyl)imide [Ntf2]-and three different cations-1-butyl-3-methylimidazolium, [C4mim], 1-ethyl-3- methylimidazolium, [C2mim] and trimethyl-butylammonium, [N 4111]-are reported between 283 and 343 K and close to atmospheric pressure. Carbon dioxide, with a mole-fraction solubility of the order of 10-2, is two orders of magnitude more soluble than hydrogen. The solubility of CO2 is very similar in the three ionic liquids although slightly lower in the presence of the [C2mim] cation. In the case of H2, noticeable differences were observed with larger mole fraction solubilities in the presence of [N4111] followed by [C 4mim]. All of the mole-fraction solubilities decrease with increasing temperature. From the variation of Henry's law constants with temperature, the thermodynamic functions of solvation were calculated. The precision of the experimental data, considered as the average absolute deviation of the Henry's law constants from appropriate smoothing equations, is always better than ±1%. © Springer Science+Business Media, LLC 2007.
Resumo:
The objective of this work was to study the influence of changing the cation of the ionic liquid (IL) on gas solubility. For this purpose, the low-pressure solubility of carbon dioxide and of ethane in three ILs based on the bis{(trifluoromethyl)sulfonyl}imide anion ([NTf2](-)) was determined experimentally. Solubility data is reported for 1-ethyl-3-methylimidazolium ([C(1)C(2)Im](+)), 1-butyl-1-methylpyrrolidinium ([C(1)C(4)pyrr](+)) and propylcholinium ([N1132-OH](+)) bis{(trifluoromethyl)sulfonyl}imide ILs between 300 and 345 K. These data are precise to within +/- 1% and accurate to within +/- 5%. In these ILs, carbon dioxide (mole fraction solubility between 1 and 3 x 10(-2), molarity between 0.03 and 0.1 mol L-1) is one order of magnitude more soluble than ethane. The effect of changing the cation is small but significant. Changing the cation has a similar effect on both gases even if the differences are more pronounced in the case of ethane with the order of solubility [C(1)C(4)pyrr][NTf2] > [C(1)C(2)Im][NTf2] > [N1132-OH][NTf2]. For all the systems, the solubility decreases with temperature corresponding to exothermic processes of solvation and negative enthalpies and entropies of solvation were calculated. The properties of solvation of the two gases in [C(1)C(4)pyrr][NTf2] do not vary significantly with temperature while important variations are depicted for both gases in [C(1)C(2)Im][NTf2]. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The densities of five imidazolium-based ionic liquids (ILs) (1-butyl-3-methylimidazolium tetrafluoroborate, [CiC4-Im][BF 4]; 1-butyl-3-methylimidazolium hexafluorophosphate, [CiC 4Im][PF6]; 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}imide, [C1C4Im][Tf 2N]; 1-ethyl-3-methylimidazoliumbis{(trifluoromethyl)sulfonyl}-imide, [C1C2Im][Tf2N]; l-ethyl-3-methylimidazolium ethylsulfate, [C1C2Im][EtSO4]) were measured as a function of temperature from (293 to 415) K and over an extended pressure range from (0.1 to 40) MPa using a vibratingtube densimeter. Knowledge of the variation of the density with temperature and pressure allows access to the mechanical coefficients: thermal expansion coefficient and isothermal compressibility. The effects of the anion and of the length of the alkyl chain on the imidazolium ring on the volumetric properties were particularly examined. The mechanical coefficients were compared with those of common organic solvents, water and liquid NaCl. Finally, a prediction model, based on an "ideal" volumetric behavior of the ILs, is proposed to allow calculation of the molar volume of imidazolium-based ionic liquids as a function of temperature. ©2007 American Chemical Society.
Resumo:
Densities and viscosities of the ionic liquid 1-butyl-3-methylimidazolium octylsulfate, [C4C1Im][C8SO4] were measured as a function of temperature between 313 K and 395 K. Solubilities of hydrogen and carbon dioxide were determined, between 283 K and 343 K, and at pressures close to atmospheric in [C4C1Im][C 8SO4] and in another ionic liquid based on the alkylsulfate anion-1-ethyl-3-methylimidazolium ethylsulfate, [C 2C1Im][C2SO4]. Density and viscosity were measured using a vibrating tube densimeter from Anton Paar and a rheometer from Rheometrics Scientific with accuracies of 10-3 g cm -3 and 1%, respectively. Solubilities were obtained using an isochoric saturation technique and, from the variation of solubility with temperature, the partial molar thermodynamic functions of solvation, such as the standard Gibbs energy, the enthalpy, and the entropy, are calculated. The precision of the experimental data, considered as the average absolute deviation of the Henry's law constants from appropriate smoothing equations, is better than ±1%. © The Royal Society of Chemistry.
Resumo:
Cataract surgery is one of the most commonly-practiced surgical procedures in Western medicine, and, while complications are rare, the most serious is infectious postoperative endophthalmitis. Bacteria may adhere to the implanted intraocular lens (IOL) and subsequent biofilm formation can lead to a chronic, difficult to treat infection. To date, no method to reduce the incidence of infectious endophthalmitis through bacterial elimination, while retaining optical transparency, has been reported. In this study we report a method to optimise the localisation of a cationic porphyrin at the surface of suitable acrylate copolymers, which is the first point of contact with potential pathogens. The porphyrin catalytically generates short-lived singlet oxygen, in the presence of visible light, which kills adherent bacteria indiscriminately. By restricting the photosensitiser to the surface of the biomaterial, reduction in optical transparency is minimised without affecting efficacy of singlet oxygen production. Hydrogel IOL biomaterials incorporating either methacrylic acid (MAA) or methyl methacrylate (MMA) co-monomers allow tuning of the hydrophobic and anionic properties to optimise the localisation of porphyrin. Physiochemical and antimicrobial properties of the materials have been characterised, giving candidate materials with self-generating, persistent anti-infective character against Gram-positive and Gram-negative organisms. Importantly, incorporation of porphyrin can also serve to protect the retina by filtering damaging shortwave visible light, due to the Soret absorption (?max) 430 nm). © 2012 Elsevier Ltd. All rights reserved.
Resumo:
Using in situ viscosity measurement, the rate of cellulose dissolution in a number of ionic liquids has been determined allowing their performance as solvents to be quantitatively assessed. 1-Butyl-3-methylimidazolium ethanoate was shown to dissolve cellulose faster than analogous ionic liquids with chloride or dimethylphosphate anions. Analysis of the data highlights the influence of both anion basicity and relative concentration on the rate of dissolution.
Resumo:
Stable chromium, molybdenum, tungsten, manganese, rhenium, ruthenium, osmium, cobalt, rhodium, and iridium metal nanoparticles (MNPs) have been reproducibly obtained by facile, rapid (3 min), and energysaving 10 W microwave irradiation (MWI) under an argon atmosphere from their metal–carbonyl precursors [Mx(CO)y] in the ionic liquid (IL) 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIm][BF4]). This MWI synthesis is compared to UV-photolytic (1000 W, 15 min) or conventional thermal decomposition (180–2508C, 6–12 h) of [Mx(CO)y] in ILs. The MWIobtained nanoparticles have a very small (<5 nm) and uniform size and are prepared without any additional stabilizers or capping molecules as long-term stable M-NP/IL dispersions (characterization by transmission electron microscopy (TEM), transmission electron diffraction (TED), and dynamic light scattering (DLS)). The ruthenium, rhodium, or iridium nanoparticle/IL dispersions are highly active
and easily recyclable catalysts for the biphasic liquid–liquid hydrogenation of cyclohexene to cyclohexane with activities of up to 522 (mol product)(mol Ru)1h1 and 884 (mol product)(molRh)1h1 and give almost quantitative conversion within 2 h at 10 bar H2 and 908C. Catalyst poisoning experiments with CS2 (0.05 equiv per Ru) suggest a heterogeneous surface catalysis of RuNPs.
Resumo:
Artificial riboflavin receptors adapted to aqueous environments were studied for their ability to selectively extract riboflavine (Rf) from three types of beverages i.e. milk, beer and a multivitamin mixture. The basic receptor was first prepared by molecular imprinting in nonaqueous medium using a hydrogen-bond donor-acceptor-donor functional monomer (2,6-bis(acrylamido)pyridine), complementary to the imide motif of the template, riboflavin tetra-acetate as template and pentaerythritol triacrylate (PETA) as a hydrophilic cross-linking monomer. The polymer was then packed in columns and used for extraction of riboflavine from beverages. Riboflavine (Rf) was selectively removed from milk and an artificial vitamin mixture but the nonspecific binding was still significant, as judged from the binding of Rf to a control nonimprinted polymer. In order to suppress this nonspecific binding, attempts to hydrolytically hydrophilize the polymer matrix were performed. The preferred approach consisted in a controlled base hydrolysis of pendent unreacted acrylate groups, using hydroxides with differently sized counterions as reagents. This resulted in a decreased binding of Rf to both polymers, but to an equal extent implying a preferential suppression of the nonspecific contribution to the binding. The hydrophilized polymers, when subjected to beer, showed larger imprinting factors at lower phase ratios compared to the nontreated polymers and a maximum removal of 86% compared to 47% for the nonimprinted control polymer.
Resumo:
The extraction of uranium(VI) from aqueous nitric acid solutions by tributylphosphate {TBP; 30%(v/v)} dissolved in the ionic liquid 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide was investigated. The experiments were performed in a Teflon microchannel of 0.5 mm internal diameter, while the dioxouranium(VI) concentrations in the aqueous and the ionic liquid phases were determined by UV-Vis spectroscopy. The effects of initial nitric acid concentration (0.01-3 M), residence time, and phase flow rate ratio were studied. It was found that, with increasing nitric acid concentration, the percentage of dioxouranium(VI) extracted decreased and then increased again, while the extraction efficiency followed a slightly different trend. Overall mass transfer coefficients varied between 0.049 s and 0.312 s . © 2012 Elsevier B.V. All rights reserved.
Resumo:
The density of ionic liquids (ILs) as a function of pressure and temperature has been modeled using a group contribution model. This model extends the calculations previously reported (Jacquemin et al. J. Chem. Eng. Data 2008) which used 4000 IL densities at 298.15 K and 600 IL densities as a function of temperature up to 423 K at 0.1 MPa to pressures up to 207 MPa by using described data in the literature and presented in this study. The densities of two different ionic liquids (butyltrimethylammonium bis(trifluoromethylsulfonyl)imide, [N][NTf], and 1-butyl-l-methyl-pyrrolidiniumbis(trifluoromethylsulfonyl)imide, [C mPyrro]-[NTf]) were measured as a function of temperature from (293 to 415) K and over an extended pressure range from (0.1 to 40) MPa using a vibrating-tube densimeter. The model is able to predict the ionic liquid densities of over 5080 experimental data points to within 0.36%. In addition, this methodology allows the calculation of the mechanical coefficients using the calculated density as a function of temperature and pressure with an estimated uncertainty of ± 20%. © 2008 American Chemical Society.
Resumo:
The two-phase flow of a hydrophobic ionic liquid and water was studied in capillaries made of three different materials (two types of Teflon, FEP and Tefzel, and glass) with sizes between 200µm and 270µm. The ionic liquid was 1-butyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide, with density and viscosity of 1420kgm and 0.041kgms, respectively. Flow patterns and pressure drop were measured for two inlet configurations (T- and Y-junction), for total flow rates of 0.065-214.9cmh and ionic liquid volume fractions from 0.05 to 0.8. The continuous phase in the glass capillary depended on the fluid that initially filled the channel. When water was introduced first, it became the continuous phase with the ionic liquid forming plugs or a mixture of plugs and drops within it. In the Teflon microchannels, the order that fluids were introduced did not affect the results and the ionic liquid was always the continuous phase. The main patterns observed were annular, plug, and drop flow. Pressure drop in the Teflon microchannels at a constant ionic liquid flow rate, was found to increase as the ionic liquid volume fraction decreased, and was always higher than the single phase ionic liquid value at the same flow rate as in the two-phase mixture. However, in the glass microchannel during plug flow with water as the continuous phase, pressure drop for a constant ionic liquid flow rate was always lower than the single phase ionic liquid value. A modified plug flow pressure drop model using a correlation for film thickness derived for the current fluids pair showed very good agreement with the experimental data. © 2013 Elsevier Ltd.