124 resultados para 90° holographic recording geometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arrays of vertically aligned gold nanotubes are fabricated over several square centimetres which display a geometry tunable plasmonic extinction peak at visible wavelengths and at normal incidence. The fabrication method gives control over nanotube dimensions with inner core diameters of 15–30 nm, wall thicknesses of 5–15 nm and nanotube lengths of up to 300 nm. It is possible to tune the position of the extinction peak through the wavelength range 600–900 nm by varying the inner core diameter and wall thickness. The experimental data are in agreement with numerical modelling of the optical properties which further reveal highly localized and enhanced electric fields around the nanotubes. The tunable nature of the optical response exhibited by such structures could be important for various label-free sensing applications based on both refractive index sensing and surface-enhanced Raman scattering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic contribution to the variation in human lifespan is approximately 25%.  Despite the large number of identified disease-susceptibility loci, it is not known which loci influence population mortality.  We performed a genome-wide association meta-analysis of 7729 long-lived individuals of European descent (≥ 85 years) and 16121 younger controls (< 65 years) followed by replication in an additional set of 13060 long-lived individuals and 61156 controls. In addition, we performed a subset analysis in cases ≥ 90 years. We observed genome-wide significant association with longevity, as reflected by survival to ages beyond 90 years, at a novel locus, rs2149954, on chromosome 5q33.3 (OR = 1.10, P =1.74 x 10-8). We also confirmed association of rs4420638 on chromosome 19q13.32 (OR = 0.72, P = 3.40 x 10-36), representing the TOMM40/APOE/APOC1 locus. In a prospective meta-analysis (n = 34103) the minor allele of rs2149954 (T) on chromosome 5q33.3 associates with increased survival (HR = 0.95, P = 0.003). This allele has previously been reported to associate with low blood pressure in middle age. Interestingly, the minor allele (T) associates with decreased cardiovascular mortality risk, independent of blood pressure. We report on the first GWAS-identified longevity locus on chromosome 5q33.3 influencing survival in the general European population. The minor allele of this locus associates with low blood pressure in middle age, although the contribution of this allele to survival may be less dependent on blood pressure. Hence, the pleiotropic mechanisms by which this intragenic variation contributes to lifespan regulation have to be elucidated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital manufacturing techniques can simulate complex assembly sequences using computer-aided design-based, as-designed' part forms, and their utility has been proven across several manufacturing sectors including the ship building, automotive and aerospace industries. However, the reality of working with actual parts and composite components, in particular, is that geometric variability arising from part forming or processing conditions can cause problems during assembly as the as-manufactured' form differs from the geometry used for any simulated build validation. In this work, a simulation strategy is presented for the study of the process-induced deformation behaviour of a 90 degrees, V-shaped angle. Test samples were thermoformed using pre-consolidated carbon fibre-reinforced polyphenylene sulphide, and the processing conditions were re-created in a virtual environment using the finite element method to determine finished component angles. A procedure was then developed for transferring predicted part forms from the finite element outputs to a digital manufacturing platform for the purpose of virtual assembly validation using more realistic part geometry. Ultimately, the outcomes from this work can be used to inform process condition choices, material configuration and tool design, so that the dimensional gap between as-designed' and as-manufactured' part forms can be reduced in the virtual environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide variety of processes make use of plain orifice nozzles. Fuel injectors for internal combustion engines incorporate these nozzles to generate finely atomized sprays. Processes such as jet cutting, jet cleaning, and hydroentanglement, on the other hand, use similar nozzles, but require coherent jets. The spray or jet characteristics depend on the stability of the flow emerging from the orifice. This problem has been extensively researched for nozzles with diameters above 300 μm. Much less is known about the characteristics of jets produced by nozzles with smaller diameters, where viscous effects and small geometric variations due to manufacturing tolerances are likely to play an increasing role. Results are presented of a wide-ranging investigation of geometry effects on the flow parameters and jet characteristics of nozzles with diameters between 120 and 170 μm. Nozzles with circular cross-section and conical, cone-capillary and capillary axial designs were investigated. For conical and cone-capillary nozzles, the effect of cone angle and effects due to interactions between adjacent nozzles in the multi-hole cone-capillary nozzles were studied. For capillary nozzles, the effects of diameter variations and inlet edge roundness for capillary nozzles were considered. Furthermore, the effect of varying the aspect ratio (ratio of major and minor axes) of elliptical nozzles was studied. Flowrate and jet impact force measurements were carried out to determine the discharge coefficient C, velocity coefficient C, and contraction coefficient C of the nozzles for supply pressures between 3 and 12 MPa. Visualizations of the jet flow were carried out in the vicinity of the nozzle exit in order to identify near-nozzle flow regimes and to study jet coherence. The relationship between nozzle geometry, discharge characteristics, and jet coherence is examined. © IMechE 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cone-capillary nozzles with varying cone angles from 10° to 120° and a capillary diameter of 120μ are experimentally investigated for their application in the hydroentanglement process. Cone-up and cone-down configurations in a range of water pressures of 30-120 bar are tested. The effects of the cone angle on flow parameters such as discharge and velocity coefficients and intact length are studied. Flow visualization techniques are used to recognize the flow regimes and characteristics and to inspect and compare the intact length and appearance of the jets. Cone-down nozzles with more consistent flow properties, lower discharges, and higher velocity coefficients are more suitable for the hydroentanglement process. Single-cone nozzles without capillaries and with varying cone angles are also tested. The flow properties of the jets from the single-cone nozzles are compared with the cone-capillary nozzles of the same cone angle to study the effect of the capillary section. The effect of the interaction of adjacent nozzles on the flow from multi-hole nozzles is studied, and the characteristics of the jets from the multi-hole nozzles are compared with the single-hole nozzles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To report any differences in the visual acuity (VA) recording method used in peer-reviewed ophthalmology clinical studies over the past decade. Methods: We reviewed the method of assessing and reporting VA in 160 clinical studies from 2 UK and 2 US peer-reviewed journals, published in 1994 and 2004. Results: The method used to assess VA was specified in 62.5% of UK-published and 60% of US-published papers. In the results sections of the UK publications the VA measurements presented were Snellen acuity (n = 58), logMAR acuity (n = 20) and symbol acuity (n = 1). Similarly in the US publications the VA was recorded in the results section using Snellen acuity (n = 60) and logMAR acuity (n = 14). Overall 10% of the authors appeared to convert Snellen acuity measurements to logMAR format. Five studies (3%) chose to express Snellen-type acuities in decimal form, a method which can easily lead to confusion given the increased use of logMAR scoring systems. Conclusion: The authors recommend that to ensure comparable visual results between studies and different study populations it would be useful if clinical scientists worked to standardized VA testing protocols and reported results in a manner consistent with the way in which they are measured. Copyright © 2008 S. Karger AG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Haematological malignancies (HM) represent over 6% of the total cancer incidence in Europe and affect all ages, ranging between 45% of all cancers in children and 7% in the elderly. Thirty per cent of childhood cancer deaths are due to HM, 8% in the elderly. Their registration presents specific challenges, mainly because HM may transform or progress in the course of the disease into other types of HM. In the context of cancer registration decisions have to be made about classifying subsequent notifications on the same patient as the same tumour (progression), a transformation or a new tumour registration. Allocation of incidence date and method of diagnosis must also be standardised. We developed European Network of Cancer Registries (ENCR) recommendations providing specific advice for cancer registries to use haematology and molecular laboratories as data sources, conserve the original date of incidence in case of change of diagnosis, make provision for recording both the original as well as transformed tumour and to apply precise rules for recording and counting multiple diagnoses. A reference table advising on codes which reflect a potential transformation or a new tumour is included. This work will help to improve comparability of data produced by population-based cancer registries, which are indispensable for aetiological research, health care planning and clinical research, an increasing important area with the application of targeted therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robust multiscale scheme referred to as micro–macro method has been developed for the prediction of localized damage in fiber reinforced composites and implemented in a finite element framework. The micro–macro method is based on the idea of partial homogenization of a structure. In this method, the microstructural details are included in a small region of interest in the structure and the rest is modeled as a homogeneous continuum. The solution to the microstructural fields is then obtained on solving the two different domains, simultaneously. This method accurately predicts local stress fields in stress concentration regions and is computationally efficient as compared with the solution of a full scale microstructural model. This scheme has been applied to obtain localized damage at high and low stress zones of a V-notched rail shear specimen. The prominent damage mechanisms under shear loading, namely, matrix cracking and interfacial debonding, have been modeled using Mohr–Coulomb plasticity and traction separation law, respectively. The average stress at the notch has been found to be 44% higher than the average stresses away from the notch for a 90 N shear load. This stress rise is a direct outcome of the geometry of the notch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we continue our investigation into the development of computational-science software based on the identification and formal specification of Abstract Data Types (ADTs) and their implementation in Fortran 90. In particular, we consider the consequences of using pointers when implementing a formally specified ADT in Fortran 90. Our aim is to highlight the resulting conflict between the goal of information hiding, which is central to the ADT methodology, and the space efficiency of the implementation. We show that the issue of storage recovery cannot be avoided by the ADT user, and present a range of implementations of a simple ADT to illustrate various approaches towards satisfactory storage management. Finally, we propose a set of guidelines for implementing ADTs using pointers in Fortran 90. These guidelines offer a way gracefully to provide disposal operations in Fortran 90. Such an approach is desirable since Fortran 90 does not provide automatic garbage collection which is offered by many object-oriented languages including Eiffel, Java, Smalltalk, and Simula.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrating analysis and design models is a complex task due to differences between the models and the architectures of the toolsets used to create them. This complexity is increased with the use of many different tools for specific tasks using an analysis process. In this work various design and analysis models are linked throughout the design lifecycle, allowing them to be moved between packages in a way not currently available. Three technologies named Cellular Modeling, Virtual Topology and Equivalencing are combined to demonstrate how different finite element meshes generated on abstract analysis geometries can be linked to their original geometry. Cellular models allow interfaces between adjacent cells to be extracted and exploited to transfer analysis attributes such as mesh associativity or boundary conditions between equivalent model representations. Virtual Topology descriptions used for geometry clean-up operations are explicitly stored so they can be reused by downstream applications. Establishing the equivalence relationships between models enables analysts to utilize multiple packages for specialist tasks without worrying about compatibility issues or substantial rework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Image

A new experimental procedure based on attenuated total reflection infrared spectroscopy has been developed to investigate surface species under liquid phase reaction conditions. The technique has been tested by investigating the enhanced selectivity in the hydrogenation of α,β-unsaturated aldehyde citral over a 5% Pt/SiO2 catalyst toward unsaturated alcohols geraniol/nerol, which occurs when citronellal is added to the reaction. The change in selectivity is proposed to be the result of a change in the citral adsorption mode in the presence of citronellal. Short time on stream attenuated total internal reflection infrared spectroscopy has allowed identification of the adsorption modes of citral. With no citronellal, citral adsorbs through both the C═C and C═O groups; however, in the presence of citronellal, citral adsorption occurs through the C═O group only, which is proposed to be the cause of the altered reaction selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Vaginal ring devices are being actively developed for controlled delivery of HIV microbicides and as multi-purpose prevention technology (MPT) products combining hormonal contraception with prevention of HIV and other sexually transmitted diseases. Presently, there is no reliable method for monitoring user adherence in HIV vaginal ring trials; previous acceptability studies have included some type of participant self-reporting mechanism, which have often been unreliable. More objective, quantitative and accurate methods for assessing adherence are needed.
Methods: A silicone elastomer vaginal ring containing an encapsulated miniature temperature recording device has been developed that can capture and store real-time temperature data during the period of designated use. Devices were tested in both simulated vaginal environments and following vaginal placement in cynomolgus macaques. Various use protocols and data sampling rates were tested to simulate typical patient usage scenarios. Results: The temperature logging devices accurately recorded vaginal temperature in macaques, clearly showing the regular diurnal temperature cycle. When environmental temperature and vaginal temperature was significantly different, the device was able to accurately pinpoint the insertion and removal times. Based on the data collected it was possible to infer removal periods as short as 5 min when the external environmental temperature was 25 °C. Accuracy increased with data sampling rate. Conclusions: This work provides proof-of-concept for monitoring adherence using a vaginal ring device containing an encapsulated temperature logger. The addition of one or more active agents into the ring body is not anticipated to affect the temperature monitoring function. A clinical study to compare self- reported user adherence data with that obtained by the device would be highly informative.