86 resultados para vehicle health monitoring (VHM) systems. Railway
Resumo:
Objectives: Health policy directs the management of patients with chronic disease in a country, but evaluating nationwide policies is difficult, not least because of the absence of suitable comparators. This paper examines the management of patients with type 2 diabetes in two demographically comparable populations with different health care systems to see if this represents a viable approach to evaluation.
Methods: A secondary analysis of centralized prescribing databases for 2010 was undertaken to compare the levels and costs of care of patients with type 2 diabetes in Northern Ireland’s National Health Service (NHS) (NI, n = 1.8 million) which has structured care, financial incentives related to diabetes care and an emphasis on generic prescribing, with that of the Republic of Ireland (ROI, n = 4.3 million) where management of diabetes care is guided solely by clinical and other guidelines.
Results: The prevalence of treated type 2 diabetes was 3.59% in NI and 3.09% in ROI, but there were similar and high levels of prescribing of secondary cardiovascular medications. Medication costs per person for anti-diabetic, anti-obesity and cardiovascular medication were 46% higher in ROI than NI, due to differences in levels of generic prescribing.
Conclusions: These different health care systems appear to be producing similar levels of care for patients with type 2 diabetes, although at different levels of cost. The findings question the need for financial incentives in NI and highlight the large cost savings potentially accruing from a greater shift to generic prescribing in ROI. Cross-country comparison, though not without difficulties, may prove a useful adjunct to within-country analysis of policy impact.
Resumo:
This paper presents a preliminary study of developing a novel distributed adaptive real-time learning framework for wide area monitoring of power systems integrated with distributed generations using synchrophasor technology. The framework comprises distributed agents (synchrophasors) for autonomous local condition monitoring and fault detection, and a central unit for generating global view for situation awareness and decision making. Key technologies that can be integrated into this hierarchical distributed learning scheme are discussed to enable real-time information extraction and knowledge discovery for decision making, without explicitly accumulating and storing all raw data by the central unit. Based on this, the configuration of a wide area monitoring system of power systems using synchrophasor technology, and the functionalities for locally installed open-phasor-measurement-units (OpenPMUs) and a central unit are presented. Initial results on anti-islanding protection using the proposed approach are given to illustrate the effectiveness.
Resumo:
This paper presents a novel method to carry out monitoring of transport infrastructure such as pavements and bridges through the analysis of vehicle accelerations. An algorithm is developed for the identification of dynamic vehicle-bridge interaction forces using the vehicle response. Moving force identification theory is applied to a vehicle model in order to identify these dynamic forces between the vehicle and the road and/or bridge. A coupled half-car vehicle-bridge interaction model is used in theoretical simulations to test the effectiveness of the approach in identifying the forces. The potential of the method to identify the global bending stiffness of the bridge and to predict the pavement roughness is presented. The method is tested for a range of bridge spans using theoretical simulations and the influences of road roughness and signal noise on the accuracy of the results are investigated.
Resumo:
This paper proposes an in situ diagnostic and prognostic (D&P) technology to monitor the health condition of insulated gate bipolar transistors (IGBTs) used in EVs with a focus on the IGBTs' solder layer fatigue. IGBTs' thermal impedance and the junction temperature can be used as health indicators for through-life condition monitoring (CM) where the terminal characteristics are measured and the devices' internal temperature-sensitive parameters are employed as temperature sensors to estimate the junction temperature. An auxiliary power supply unit, which can be converted from the battery's 12-V dc supply, provides power to the in situ test circuits and CM data can be stored in the on-board data-logger for further offline analysis. The proposed method is experimentally validated on the developed test circuitry and also compared with finite-element thermoelectrical simulation. The test results from thermal cycling are also compared with acoustic microscope and thermal images. The developed circuitry is proved to be effective to detect solder fatigue while each IGBT in the converter can be examined sequentially during red-light stopping or services. The D&P circuitry can utilize existing on-board hardware and be embedded in the IGBT's gate drive unit.
Resumo:
The monitoring of oral disease is important, not alone for oral health, but for the detection and prevention of
systemic disease. The link between oral health and systemic disease is the focus of many studies, with
indications emerging of a causal link [1]. For disease diagnostics, blood has typically been the fluid of choice
for analysis, the retrieval of which is invasive and therefore unsuitable for wearable technology. Analysis of
saliva, however, is less invasive than that of blood, requires little or no pre-treatment and is abundantly
available. A strong correlation has been found between the analytes of blood and saliva [2] with saliva
containing biomarkers for diseases such as diabetes, oral cancer and cardiovascular disease. The development of
an implantable multi-parametric wireless sensor, to monitor both salivary analytes and changes in gingival
temperature, is the aim of this research project.
The aim of our current study is to detect changes in salivary pH, using a gold electrode with a pHsensitive
iridium oxide layer, and an Ion Sensitive Field Effect Transistor probe. Characterisation studies were
carried out in artificial saliva (AS). A salivary pH of between 4.5pH-7.5pH [3], and gingival temperature
between 35°C-38°C [4], were identified as the target range of interest for the human oral environment. Sensor
measurements were recorded in solutions of varying pH and temperature. An ISFET probe was then implanted
into a prototype denture and characterised in AS. This study demonstrates the suitability of ISFET and gold
electrode pH sensors for incorporation into implantable oral sensors.
[1] G. Taylor and W. Borgnakke, “Periodontal disease: associations with diabetes, glycemic control and
complications,” Oral Dis., vol. 14, no. 3, pp. 191–203, Apr. 2008.
[2] E. Tékus, M. Kaj, E. Szabó, N. L. Szénási, I. Kerepesi, M. Figler, R. Gábriel, and M. Wilhelm,
“Comparison of blood and saliva lactate level after maximum intensity exercise,” Acta Biol. Hung., vol. 63
Suppl 1, pp. 89–98, 2012.
[3] S. Naveen, M. L. Asha, G. Shubha, A. Bajoria, and A. Jose, “Salivary Flow Rate, pH and Buffering
Capacity in Pregnant and Non Pregnant Women - A Comparative Study,” JMED Res., pp. 1–8, Feb. 2014.
[4] A. F. Holthuis and F. S. Chebib, “Observations on temperature and temperature patterns of the gingiva. I.
The effect of arch, region and health,” J. Periodontol., vol. 54, no. 10, pp. 624–628, Oct. 1983
Resumo:
Objectives: To explore the views of eye health professionals and service users on shared community and hospital care for wet or neovascular age-related macular degeneration (nAMD).
Method: Using maximum variation sampling, 5 focus groups and 10 interviews were conducted with 23 service users and 24 eye health professionals from across the UK (consisting of 8 optometrists, 6 ophthalmologists, 6 commissioners, 2 public health representatives and 2 clinical eye care advisors to local Clinical Commissioning Groups). Data were transcribed verbatim and analysed thematically using constant comparative techniques derived from grounded theory methodology.
Results: The needs and preferences of those with nAMD appear to be at odds with the current service being provided. There was enthusiasm among health professionals and service users about the possibility of shared care for nAMD as it was felt to have the potential to relieve hospital eye service burden and represent a more patient-centred option, but there were a number of perceived barriers to implementation. Some service users and ophthalmologists voiced concerns about optometrist competency and the potential for delays with referrals to secondary care if stable nAMD became active again. The health professionals were divided as to whether shared care was financially more efficient than the current model of care. Specialist training for optometrists, under the supervision of ophthalmologists, was deemed to be the most effective method of training and was perceived to have the potential to improve the communication and trust that shared care would require.
Conclusions: While shared care is perceived to represent a promising model of nAMD care, voiced concerns suggest that there would need to be greater collaboration between ophthalmology and optometry, in terms of interprofessional trust and communication.
Resumo:
A wearable silver nano particle inkjet printed antenna suitable for wireless biomedical sensing is presented. The performance is evaluated on a synthetic variable layered phantom test-bed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with antennas prototyped with copper. Total radiation efficiencies up to ???6.5 dB are reported, with less than 0.5 dB difference in performance between copper and silver nano particle variants, showing promising application for low-cost disposable wireless sensing.
Resumo:
Introduction
This report details the findings from research conducted across Northern Ireland’s Health and Social Care Trusts during 2015 which examines the current state of Personal and Public Involvement (PPI). This is about how service users, carers and patients engage with staff, management and directors of statutory health and social care organisations. Most statutory health and social care organisations must, under legislation, meet the requirements of PPI. PPI has been part of health and social care policy in Northern Ireland since 2007 and became law two years later with the introduction of the Health and Social Care Reform Act (2009). It is, therefore, timely that PPI is now assessed in this systematic way in order to both examine the aspects which are working well and to highlight those areas where improvements need to be made. As far as possible, this Summary Report is written in an accessible way, avoiding jargon and explaining key research terms, so as to ensure it is widely understood. This is in keeping with established good practice in service user involvement research. This summary, therefore, gives a picture of PPI in Northern Ireland currently. There is also a fuller report which gives a lot more details about the research and findings. Information on this is available from the Public Health Agency and/or the Patient and Client Council.