128 resultados para unit disk graphs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Newborn Individualized Developmental Care and Assessment Program (NIDCAP) is widely used in neonatal intensive care units and comprises 85 discrete infant behaviors, some of which may communicate infant distress. The objective of this study was to identify developmentally relevant movements indicative of pain in preterm infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of glutamine as a dietary supplement is associated with a reduced risk of infection. We hypothesized that the underlying mechanism could be an increase in the expression and/or functionality of Toll-like receptors (TLR), key receptors sensing infections. The objective of this study was to evaluate whether glutamine supplementation alters the expression and functionality of TLR2 and TLR4 in circulating monocytes of trauma patients admitted to the intensive care unit (ICU).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: A retrospective audit was conducted into Clinical Psychology referrals made by the adult cystic fibrosis (CF) team over a ten year period from 2001-2010. The aim of the audit was to examine the psychological difficulties referred to Clinical Psychology and identify any trends.
Methods: A database of all referrals received over a ten year period was created. A coding template was created by KR and AC which allowed for the categorisation of referrals into three main themes: Mood disturbance, CF related events and non-CF related events. The same coding template was used to categorise referrals to the children’s CF service. Descriptive statistics were used to interpret the data.
Results: In 2009/10, 11% of the adult CF population in Northern Ireland were referred to Clinical Psychology. In the past 10 years there were 200 referrals and 105 adults who accessed Clinical Psychology services. The majority of referrals (67%) were re-referrals (range 2-7). More females were referred and they were also more likely to be referred repeatedly The main reason for referral was anxiety. Depression, adherence and end of life/transplant issues also accounted for a large proportion of referrals. A small proportion of referrals were due to non CF related events. There were age and gender differences in the reasons for referral.
Conclusion: A minority of CF patients attending the regional unit were referred to Clinical Psychology. Those who accessed the services appear to be at increased risk of psychological morbidity as re-referral rates are high. The gender difference in referral and re-referral rates may reflect a difference in psychological morbidity or males not accessing services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the clinical agreement in the detection of optic disk changes in patients with glaucoma using simultaneous stereophotographs. DESIGN: Masked-observer variability study. METHODS: Ten glaucoma specialists examined pairs of simultaneous stereophotographs of glaucomatous and control optic disks to determine whether there were changes compatible with progression of glaucomatous damage. RESULTS: Intraobserver agreement had a kappa value ranging from 0.55 to 0.78. Interobserver agreement among the glaucoma specialists had a kappa value ranging from 0.34 to 0.68. CONCLUSION: Clinical examination of stereophotographs to detect optic disk changes in glaucoma patients has limitations associated with suboptimal reproducibility. © 2003 by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of the screening mode of the Humphrey-Welch Allyn frequency-doubling technology (FDT), Octopus tendency-oriented perimetry (TOP), and the Humphrey Swedish Interactive Threshold Algorithm (SITA)-fast (HSF) in patients with glaucoma. DESIGN: A comparative consecutive case series. METHODS: This was a prospective study which took place in the glaucoma unit of an academic department of ophthalmology. One eye of 70 consecutive glaucoma patients and 28 age-matched normal subjects was studied. Eyes were examined with the program C-20 of FDT, G1-TOP, and 24-2 HSF in one visit and in random order. The gold standard for glaucoma was presence of a typical glaucomatous optic disk appearance on stereoscopic examination, which was judged by a glaucoma expert. The sensitivity and specificity, positive and negative predictive value, and receiver operating characteristic (ROC) curves of two algorithms for the FDT screening test, two algorithms for TOP, and three algorithms for HSF, as defined before the start of this study, were evaluated. The time required for each test was also analyzed. RESULTS: Values for area under the ROC curve ranged from 82.5%-93.9%. The largest area (93.9%) under the ROC curve was obtained with the FDT criteria, defining abnormality as presence of at least one abnormal location. Mean test time was 1.08 ± 0.28 minutes, 2.31 ± 0.28 minutes, and 4.14 ± 0.57 minutes for the FDT, TOP, and HSF, respectively. The difference in testing time was statistically significant (P <.0001). CONCLUSIONS: The C-20 FDT, G1-TOP, and 24-2 HSF appear to be useful tools to diagnose glaucoma. The test C-20 FDT and G1-TOP take approximately 1/4 and 1/2 of the time taken by 24 to 2 HSF. © 2002 by Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the reproducibility of optic disk measurements provided by an image analyzer and a scanning laser tomograph. Methods: Ten images of the same eye of 10 normal volunteers were taken with the Heidelberg Retina Tomograph and with the Topcon ImageNet. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to evaluate the reproducibility of the measurements. Results: Eleven parameters were analyzed with the Topcon ImageNet. Six parameters (55%) had ICC greater than 90%. Four parameters (36%) had CV less than 10%. Twelve parameters were evaluated with the Heidelberg Retina Tomograph. Nine parameters (75%) had ICC over 90%. Nine parameters (75%) had CV less than 10%. Conclusion: Both systems provided reproducible data. The optic disk parameters provided by the Heidelberg Retina Tomograph had a better reproducibility than those obtained from the Topcon ImageNet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of sharing the cost of a network that meets the connection demands of a set of agents. The agents simultaneously choose paths in the network connecting their demand nodes. A mechanism splits the total cost of the network formed among the participants. We introduce two new properties of implementation. The first property, Pareto Nash implementation (PNI), requires that the efficient outcome always be implemented in a Nash equilibrium and that the efficient outcome Pareto dominates any other Nash equilibrium. The average cost mechanism and other asymmetric variations are the only mechanisms that meet PNI. These mechanisms are also characterized under strong Nash implementation. The second property, weakly Pareto Nash implementation (WPNI), requires that the least inefficient equilibrium Pareto dominates any other equilibrium. The egalitarian mechanism (EG) and other asymmetric variations are the only mechanisms that meet WPNI and individual
rationality. EG minimizes the price of stability across all individually rational mechanisms. © Springer-Verlag Berlin Heidelberg 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a case-study of a PMU application with PSS support in a real large scale Chinese power system to suppress inter-area oscillations. The paper uses PMU measured feedback signals from a PSS input signal for dynamic torque analysis (DTA). In the paper, a mathematical model of multi-machine power system is described, followed by formation of the residue and DTA indices. Simulations of the model are used with a large-scale power system model to demonstrate the role of PSS and the equivalence of DTA residue indices.