102 resultados para plastic thatch manufacture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design and manufacture of aircraft requires deep multi-disciplinary understanding of system behaviour. The intention of the designer can get lost due to the many changes occurring to the product and the inability of the methods and tools used to capture it. Systems engineering and optimisation tools underpin industrial approaches to design, but are not without issue. The challenge is to find a route from concept to manufacture which enables designers to maintain their original intent. The novelty in this work is that the parameterisation used to build the CAD model reflects the manufacturing capability, ensuring design intent is maintained from concept to manufacture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to investigate drilling process in carbon-fiber reinforced plastic (CFRP) composites with multilayer TiAlN/TiN PVD-coated tungsten carbide drill. The effect of process parameters have been investigated in drilling of Hexcel M21-T700GC. Thrust force and torque were measured online throughout the drilling experiments. Delamination were observed using optical microscope and analyzed via a developed algorithm based on digital image processing technique. Surface roughness of each hole was measured using a surface profilometer. In addition, the progression of tool wear in various surfaces of drill was observed using tool microscope and measured using image software. Our results indicate that the thrust force and torque increased with the increasing cutting speed and feed rate. Delamination and average surface roughness that rose with the increase in feed rate, however, decreased with the increasing cutting speed. The average surface roughness tended to increase with the increase in feed rate and decrease with the increasing cutting speed in drilling of carbon-fiber reinforced plastic (CFRP). Feed rate was found as the predominant factor on the drilling outputs. Abrasive wear was observed on both flank and relief surfaces, which created edge wear on cutting edges. No sign of chipping or plastic deformation has been observed on the surfaces of drills. © 2012 The Author(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of manufacturing a composite concrete article comprising affixing at least one layer of textile to a base layer and incorporating the base layer into a body of wet uncured concrete such that the base layer becomes embedded in the concrete, whereby at least a portion of the at least one textile layer defines at least a portion of a surface of the cured concrete article with the base layer embedded within the concrete to anchor the textile layer to the concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study was designed to evaluate the structures, muscles, and fasciae of which the modiolus is composed. It can aid in the understanding and, therefore, the utilization of plastic surgery for the aesthetic or reconstructive treatment of that region, especially the angle of the mouth. Methods: Dissections of the midface were done on five different cadavers. They were of different races (3 males, 2 females). The anatomy of the modiolus was studied in detail. New anatomical observations were classified as type I through type VI. Results: The perifacial artery fascia contributed to the modiolus in four (80%) specimens and was not part of it in 1 (20%) specimen. The facial artery was anterior to it in one (20%) specimen, lateral in four (80%) specimens, and never medial to it. No significant relationship was observed between the perifacial artery fascia contribution to the modiolus and gender or race. Also, the location of the facial artery lateral or anterior to the modiolus was not significantly related to gender or race. In addition, the deep and superficial fasciae of the face converged not anterior to the masseter muscle but actually at the modiolus, which was different from observations made by others. Conclusion: The modiolus is of critical importance in aesthetic and reconstructive plastic surgery of the face. © 2008 Springer Science+Business Media, LLC and International Society of Aesthetic Plastic Surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a study done for the first time to understand the histologic features of the lip deeply, quantitatively, and analytically and identify the differences between the outer, intermediate, and inner parts of the lips. Previous researchers did not tackle the histologic features of the lip from this point of view. Half lip was obtained from different well-preserved cadavers where the upper lip, lower lip, and lip angle were evaluated by coronal histologic sections. A total of 43 slides were studied and photographed using light and digital microscopes (Nikon COOLSCOPE, Nikon Corporation, Tokyo, Japan), respectively. The cadavers (26 men and 17 women) were in the age group of 45 to 65 years old, and older than 65 years. Data were entered on a study pro forma and statistically analyzed. Normal histologic features of the upper lip, intermediate, and the inner lip sections were observed. Fibrous septations that sometimes had muscular components inserting into them could be identified. In between these septations, there were loose areas (chambers). The mean numbers of chambers identified in the upper and lower lips were higher in the red areas, and more septations and chambers were identified in the lower lip. New histologic observations were classified into types 1 to 7. Significant relations were identified between the total number of septations and chambers in relation to age group and sex. Higher means of septations and chambers were detected in the age group older than 65 years, and in women as a whole. In conclusion, the findings detected in this work could explain the congenital lip pits that are familial or syndromic and many post-lip augmentation complications. © 2009 Lippincott Williams & Wilkins, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioresorbable polymers such as PLA have an important role to play in the development of temporary implantable medical devices with significant benefits over traditional therapies. However, development of new devices is hindered by high manufacturing costs associated with difficulties in processing the material. A major problem is the lack of insight on material degradation during processing. In this work, a method of quantifying degradation of PLA using IR spectroscopy coupled with computational chemistry and chemometric modeling is examined. It is shown that the method can predict the quantity of degradation products in solid-state samples with reasonably good accuracy, indicating the potential to adapt the method to developing an on-line sensor for monitoring PLA degradation in real-time during processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Milling of plant and soil material in plastic tubes, such as microcentrifuge tubes, over-estimates carbon (C) and under-estimates nitrogen (N) concentrations due to the introduction of polypropylene into milled samples, as identified using Fourier-transform infra-red spectroscopy.

This study compares C and N concentrations of roots and soil milled in microcentrifuge tubes versus stainless steel containers, demonstrating that a longer milling time, greater milling intensity, smaller sample size and inclusion of abrasive sample material all increase polypropylene contamination from plastic tubes leading to overestimation of C concentrations by up to 8 % (0.08 g g(-1)).

Erroneous estimations of C and N, and other analytes, must be assumed after milling in plastic tubes and milling methods should be adapted to minimise such error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe, for the first time, considerations in the sterile manufacture of polymeric microneedle arrays. Microneedles (MN) made from dissolving polymeric matrices and loaded with the model drugs ovalbumin (OVA) and ibuprofen sodium and hydrogel-forming MN composed of "super-swelling" polymers and their corresponding lyophilised wafer drug reservoirs loaded with OVA and ibuprofen sodium were prepared aseptically or sterilised using commonly employed sterilisation techniques. Moist and dry heat sterilisation, understandably, damaged all devices, leaving aseptic production and gamma sterilisation as the only viable options. No measureable bioburden was detected in any of the prepared devices, and endotoxin levels were always below the US Food & Drug Administration limits (20 endotoxin units/device). Hydrogel-forming MN were unaffected by gamma irradiation (25 kGy) in terms of their physical properties or capabilities in delivering OVA and ibuprofen sodium across excised neonatal porcine skin in vitro. However, OVA content in dissolving MN (down from approximately 101.1 % recovery to approximately 58.3 % recovery) and lyophilised wafer-type drug reservoirs (down from approximately 99.7 % recovery to approximately 60.1 % recovery) was significantly reduced by gamma irradiation, while the skin permeation profile of ibuprofen sodium from gamma-irradiated dissolving MN was markedly different from their non-irradiated counterparts. It is clear that MN poses a very low risk to human health when used appropriately, as evidenced here by low endotoxin levels and absence of microbial contamination. However, if guarantees of absolute sterility of MN products are ultimately required by regulatory authorities, it will be necessary to investigate the effect of lower gamma doses on dissolving MN loaded with active pharmaceutical ingredients and lyophilised wafers loaded with biomolecules in order to avoid the expense and inconvenience of aseptic processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar water disinfection (SODIS) is a well-established inexpensive means of water disinfection in developing countries, but lacks an indicator to illustrate its end-point. A study of the solar UV dosage required for SODIS, in order to achieve a bacteria concentration below the detection limit for: Escherichia coli, Enterococcus spp. and Clostridium perfringens, in water in PET bottles, PE and PE/EVA bags showed disinfection to be most efficient in PE bags, with a solar UV (290–385 nm) dose of 389 kJ m−2 required. In parallel to the disinfection experiments, a range of polyoxometalate, semiconductor photocatalysis and photodegradable dye-based solar UV dosimeter indicators were tested under the same solar UV irradiation conditions. All three types of dosimeter produced indicators that largely and significantly change colour upon exposure to 389 kJ m−2 solar UV; further indicators are reported which change colour at higher doses and hence would be suitable for the less efficient SODIS containers tested. All indicators tested were robust, easy to use and inexpensive so as not to add significantly to the attractive low cost of SODIS. Furthermore, whilst semiconductor photocatalyst and photodegradable dye based indicators are disposable, one-use systems, the polyoxometalate based indicators recover colour in the dark overnight, allowing them to be reused, and hence further decreasing the cost of using indicators during the implementation of the SODIS method.