84 resultados para filmic images


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BARTON 1 has suggested that photoelectron interference patterns may be used directly as holograms to obtain atomic-resolution images of surface structures. Bulk structures have been obtained previously by this means from experimental patterns of high-energy Kikuchi(quasi-elastically scattered) and Auger electrons 2,3. Here we test the feasibility of this technique for determination of surface structures using Auger intensity patterns obtained 4,5 from iodine chemisorbed on a pseudomorphic silver monolayer on Pt{111}. By direct numerical holographic inversion, we obtain three-dimensional images which show that iodine adatoms are located in hollows of 3-fold symmetry on the surface. The images yield the site symmetry with good atomic resolution in the surface plane, but suffer from poor resolution along the Ag-I axis. We anticipate that data with better angular resolution obtained at low temperatures would improve the spatial resolution of such images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Identifying new and more robust assessments of proficiency/expertise (finding new "biomarkers of expertise") in histopathology is desirable for many reasons. Advances in digital pathology permit new and innovative tests such as flash viewing tests and eye tracking and slide navigation analyses that would not be possible with a traditional microscope. The main purpose of this study was to examine the usefulness of time-restricted testing of expertise in histopathology using digital images.
Methods: 19 novices (undergraduate medical students), 18 intermediates (trainees), and 19 experts (consultants) were invited to give their opinion on 20 general histopathology cases after 1 s and 10 s viewing times. Differences in performance between groups were measured and the internal reliability of the test was calculated.
Results: There were highly significant differences in performance between the groups using the Fisher's least significant difference method for multiple comparisons. Differences between groups were consistently greater in the 10-s than the 1-s test. The Kuder-Richardson 20 internal reliability coefficients were very high for both tests: 0.905 for the 1-s test and 0.926 for the 10-s test. Consultants had levels of diagnostic accuracy of 72% at 1 s and 83% at 10 s.
Conclusions: Time-restricted tests using digital images have the potential to be extremely reliable tests of diagnostic proficiency in histopathology. A 10-s viewing test may be more reliable than a 1-s test. Over-reliance on "at a glance" diagnoses in histopathology is a potential source of medical error due to over-confidence bias and premature closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social acceptance for wind turbines is variable, providing a challenge to the implementation of this energy source. Psychological research could contribute to the science of climate change. Here we focus on the emotional responses to the visual impact of wind turbines on the landscape, a factor which dominates attitudes towards this technology. Participants in the laboratory viewed images of turbines and other constructions (churches, pylons and power-plants) against rural scenes, and provided psychophysiological and self-report measures of their emotional reactions. We hypothesised that the emotional response to wind turbines would be more negative and intense than to control objects, and that this difference would be accentuated for turbine opponents. As predicted, the psychophysiological response to turbines was stronger than the response to churches, but did not differ from that of other industrial constructions. In contrast with predictions, turbines were rated as less aversive and more calming compared with other industrial constructions, and equivalent to churches. Supporters and non-supporters did not differ significantly from each other. We discuss how a methodology using photo manipulations and emotional self-assessments can help estimate the emotional reaction to the visual impact on the landscape at the planning stage for new wind turbine applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses on quantifying the benefits of pictogram based instructions relative to static images for work instruction delivery. The assembly of a stiffened aircraft panel has been used as an exemplar for the work which seeks to address the challenge of identifying an instructional mode that can be location or language neutral while at the same time optimising assembly build times and maintaining build quality. Key performance parameters measured using a series of panel build experiments conducted by two separate groups were: overall build time, the number of subject references to instructional media, the number of build errors and the time taken to correct any mistakes. Overall build time for five builds for a group using pictogram instructions was about 20% lower than for the group using image based instructions. Also, the pictogram group made fewer errors. Although previous work identified that animated instructions result in optimal build times, the language neutrality of pictograms as well as the fact that they can be used without visualisation hardware mean that, on balance, they have broader applicability in terms of transferring assembly knowledge to the manufacturing environment.