123 resultados para device for counting,
Resumo:
Varying intensities of nurse-mediated health education advice were administered to subjects over a three-month period. Mean serum total cholesterol was calculated for each group at the outset and completion of the study. A multidimensional health locus of control (MHLC) scales questionnaire was self-completed by subjects at the outset. A highly significant association between internality and reduction in serum total cholesterol in the high-intensity intervention group was observed. The completion of a MHLC scale questionnaire may assist health professionals in identifying which subjects may most benefit from high-intensity health education advice when raised serum total cholesterol is prevalent.
Resumo:
In response to claims that the quality (and in particular linearity) of children's mental representation of number acts as a constraint on number development, we carried out a longitudinal assessment of the relationships between number line estimation, counting, and mathematical abilities. Ninety-nine 5-year-olds were tested on 4 occasions at 3 monthly intervals. Correlations between the 3 types of ability were evident, but while the quality of children's estimations changed over time and performance on the mathematical tasks improved over the same period, changes in one were not associated with changes in the other. In contrast to the earlier claims that the linearity of number representation is potentially a unique contributor to children's mathematical development, the data suggest that this variable is not significantly privileged in its impact over and above simple procedural number skills. We propose that both early arithmetic success and estimating skill are bound closely to developments in counting ability.
Resumo:
Hydrogen is detected using a Pd/n-InP Schottky diode in which the elongated, very thin Pd electrode is of greater resistance than the underlying semiconductor substrate. Four-probe measurements of the device resistance, as a function of hydrogen concentration, are made by contacting only the Pd electrode, with a sensitivity of 1 ppm being achieved. On hydrogen exposure the device resistance drops from an initial high value, characteristic of the Pd electrode alone, to a lower value due to a hydrogen-induced lowering of the Schottky barrier that opens up the InP substrate as a parallel current carrying channel.
Resumo:
PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.
PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.
RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.
CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.
Resumo:
Patients with spontaneous lens dislocation and glaucoma can be challenging to manage. We present a forty-six year old Caucasian lady who was referred with bilateral high intraocular pressure, and was subsequently diagnosed with glaucoma in association with lens dislocation and Marfan syndrome. Baerveldt glaucoma drainage device tubes were inserted in both eyes due to poor response to medical therapy. However, this was complicated by recurrent vitreous occlusion of both glaucoma drainage tubes requiring further multiple surgical interventions. There have not been any further recurrences of vitreous incarceration or posterior segment complications since, but the patient remains under close follow-up. © 2010 Ang et al; licensee BioMed Central Ltd.
Resumo:
A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.
Resumo:
The susceptibility of WiFi networks to Rogue Access Point attacks derives from the lack of identity for 802.11 devices. The most common means of detecting these attacks in current research is through tracking the credentials or the location of unauthorised and possibly malicious APs. In this paper, the authors outline a method of distinguishing WiFi Access Points using 802.11 MAC layer management frame traffic profiles. This system does not require location estimation or credential tracking techniques as used in current research techniques, which are known to be inaccurate. These characteristic management traffic profiles are shown to be unique for each device, tantamount to a MAC identity. The application of this technique to solving Rogue AP attacks under the constraints of an open access, public WiFi environment is discussed with the conclusion that the identity is practically very difficult to forge
Resumo:
Two short site-specific pieces performed with others at the Royal Ulster Agricultural Show for Kabosh Theatre Company, as part of their continuing effort to broaden theatre audiences. One, using the form of the Edwardian melodrama, tells of Marconi's efforts to create a device to communicate with the dead. The second tells the tale of the Christian Brother who invented the submarine, John Philip Holland.
Resumo:
The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.