92 resultados para Taylor made
Resumo:
A new pathway to (+)-inthomycin C is reported that exploits an O-directed free radical hydrostannation reaction on (−)-12 and a Stille cross-coupling as key steps. Significantly, the latter process was effected on 19 where a gauche-pentane repulsive interaction could interfere. Our stereochemical studies on the alkynol (−)-12 and the enyne (+)-7 confirm that Ryu and Hatakeyama’s (3S)-stereochemical revision of (+)-inthomycin C is invalid and that Zeeck and Taylor’s original (3R)-stereostructure for (+)-inthomycin C is correct.
Resumo:
Chloride-induced corrosion of steel in reinforced concrete structures is one of the main problems affecting their durability and it has been studied for decades, but most of them have focused on concrete without cracking or not subjected to any structural load. In fact, concrete structures are subjected to various types of loads, which lead to cracking when the tensile stress in concrete exceeds its tensile strength. Cracking could increase transport properties of concrete and accelerate the ingress of harmful substances (Cl -, O2, H2 O, CO2). This could initiate and accelerate different types of deterioration processes in concrete, including corrosion of steel reinforcement. The expansive products generated by the deterioration processes themselves can initiate cracking. The success of concrete patch repairs can also influence microcracking at the interface as well as the patch repair itself. Therefore, monitoring the development of microcracking in reinforced concrete members is extremely useful to assess the defects and deterioration in concrete structures. In this paper, concrete beams made using 4 different mixes were subjected to three levels of sustained lateral loading (0%, 50% and 100% of the load that can induce a crack with width of 0.1mmon the tension surface of beams - F 0.1) and weekly cycles of wetting (1 day)/drying (6 days) with chloride solution. The development of microcracking on the surface of concrete was monitored using the Autoclam Permeability System at every two weeks for 60 weeks. The ultrasonic pulse velocity of the concrete was also measured along the beam by using the indirect method during the test period. The results indicated that the Autoclam Permeability System was able to detect the development of microcracks caused by both sustained loading and chloride induced corrosion of steel in concrete. However, this was not the case with the ultrasonic method used in the work (indirect method applied along the beam); it was sensitive to microcracking caused by sustained loading but not due to corrosion. © 2014 Taylor & Francis Group.
Resumo:
Developing the controversy indicated in the heading, this article will proceed as follows. It establishes a notion of critical comparative law, by showing how comparative law may be capable of providing critique and analysis of law-making through judicial and legislative activity at a European level. This is followed by an exemplary discussion of how comparative law is actually used in relation to European harmonisation through case law, legislation and “soft law”. The question will then be asked whether and how these uses would change under a critical approach to comparative law. The discussion will focus on industrial relations and equality law.
In both fields, recent ECJ case law has proved controversial: This article submits that such controversy could partly be avoided by making better use of critical comparative law in deciding cases and in choosing adequate forms and content of legislation.
Resumo:
Evidence for osseous technologies has featured in excavation reports from Southeast Asia for almost a century and from archaeological deposits as old as 43,000 years BP. However, in contrast to the significance that is placed on this technology in other parts of the world, until recently, Southeast Asian assemblages have drawn only very limited attention. Concentrating on evidence from Malaysia, the current paper examines one element of this inventory of tools: the deliberate modification of pig canines and the means by which such alteration can be distinguished from patterns of natural tooth wear. Particular attention is paid to the bearded pig (Sus barbatus), as it is one of the two species of wild boar in Malaysia whose tusks are most likely to have been used by prehistoric toolmakers. Reference is also made to wider, regional ethnographic examples of known tusk implements and their accredited uses to further assist in the identification process. Distinguishing criteria for worked tusk are formulated according to the type and extent of modification. These criteria are then applied to archaeological specimens recovered from two prehistoric cave sites in Malaysia, Gua Bintong and Niah Cave.
Resumo:
Molecular Medicine and Molecular Pathology are integral parts of Haematology as we enter the new millennium. Their origins can be linked to fundamental developments in the basic sciences, particularly genetics, chemistry and biochemistry. The structure of DNA and the genetic code that it encrypts are the critical starting points to our understanding of these new disciplines. The genetic alphabet is a simple one, consisting of just 4 letters, buts its influence is crucial to human development and differentiation. The concept of a gene is not a new one but the Human Genome Project (a joint world-wide effort to characterise our entire genetic make-up) is providing an invaluable understanding of how genes function in normal cellular processes and pinpointing how disruption of these processes can lead to disease. Transcription and translation are the key events by which our genotype is converted to our phenotype (via a messenger RNA intermediate), producing the myriad proteins and enzymes which populate the cellular factory of our body. Unlike the bacterial or prokaryotic genome, the human genome contains a large amount of non coding DNA (less than 1% of our genome codes for proteins), and our genes are interrupted, with the coding regions or exons separated by non coding introns. Precise removal of the intronic material after transcription (though a process called splicing) is critical for efficient translation to occur. Incorrect splicing can lead to the generation of mutant proteins, which can have a dilaterious effect on the phenotype of the individual. Thus the 100,000-200,000 genes which are present in each cell in our body have a defined control mechanism permitting efficient and appropriate expression of proteins and enzymes and yet a single base change in just one of those genes can lead to diseases such as haemophilia or fanconis anaemia.
Resumo:
This paper presents an experimental study evaluating the effectiveness of the Near Surface Mounted (NSM) technique with innovative manually made FRP bars (MMFRP) for shear strengthening of RC beams. RC beams designed to fail in shear were tested in three-point bending. To delay the onset of MMFRP bar debonding, a new anchorage is also developed and tested. This paper reports the results of a series of tests on simply supported rectangular RC beams, strengthened in shear with MMFRP bar either with or without the proposed anchorage. The load-deflection responses of all test beams are plotted, in addition to selected strain results. Performance and the failure modes of the test beams are presented and discussed in this paper. The proposed MMFRP bars and end anchorage enhanced the shear capacity between 25 to 48% over the control specimen. Furthermore, the adoption of the proposed end anchorage of MMFRP bars significantly enhanced the ductility of the test specimens.
Resumo:
Introduction: It has been suggested that doctors in their first year of post-graduate training make a disproportionate number of prescribing errors.
Obkective: This study aimed to compare the prevalence of prescribing errors made by first-year post-graduate doctors with that of errors by senior doctors and non-medical prescribers and to investigate the predictors of potentially serious prescribing errors.
Methods: Pharmacists in 20 hospitals over 7 prospectively selected days collected data on the number of medication orders checked, the grade of prescriber and details of any prescribing errors. Logistic regression models (adjusted for clustering by hospital) identified factors predicting the likelihood of prescribing erroneously and the severity of prescribing errors.
Results: Pharmacists reviewed 26,019 patients and 124,260 medication orders; 11,235 prescribing errors were detected in 10,986 orders. The mean error rate was 8.8 % (95 % confidence interval [CI] 8.6-9.1) errors per 100 medication orders. Rates of errors for all doctors in training were significantly higher than rates for medical consultants. Doctors who were 1 year (odds ratio [OR] 2.13; 95 % CI 1.80-2.52) or 2 years in training (OR 2.23; 95 % CI 1.89-2.65) were more than twice as likely to prescribe erroneously. Prescribing errors were 70 % (OR 1.70; 95 % CI 1.61-1.80) more likely to occur at the time of hospital admission than when medication orders were issued during the hospital stay. No significant differences in severity of error were observed between grades of prescriber. Potentially serious errors were more likely to be associated with prescriptions for parenteral administration, especially for cardiovascular or endocrine disorders.
Conclusions: The problem of prescribing errors in hospitals is substantial and not solely a problem of the most junior medical prescribers, particularly for those errors most likely to cause significant patient harm. Interventions are needed to target these high-risk errors by all grades of staff and hence improve patient safety.
Resumo:
Bridge weigh-in-motion (B-WIM), a system that uses strain sensors to calculate the weights of trucks passing on bridges overhead, requires accurate axle location and speed information for effective performance. The success of a B-WIM system is dependent upon the accuracy of the axle detection method. It is widely recognised that any form of axle detector on the road surface is not ideal for B-WIM applications as it can cause disruption to the traffic (Ojio & Yamada 2002; Zhao et al. 2005; Chatterjee et al. 2006). Sensors under the bridge, that is Nothing-on-Road (NOR) B-WIM, can perform axle detection via data acquisition systems which can detect a peak in strain as the axle passes. The method is often successful, although not all bridges are suitable for NOR B-WIM due to limitations of the system. Significant research has been carried out to further develop the method and the NOR algorithms, but beam-and-slab bridges with deep beams still present a challenge. With these bridges, the slabs are used for axle detection, but peaks in the slab strains are sensitive to the transverse position of wheels on the beam. This next generation B-WIM research project extends the current B-WIM algorithm to the problem of axle detection and safety, thus overcoming the existing limitations in current state-of–the-art technology. Finite Element Analysis was used to determine the critical locations for axle detecting sensors and the findings were then tested in the field. In this paper, alternative strategies for axle detection were determined using Finite Element analysis and the findings were then tested in the field. The site selected for testing was in Loughbrickland, Northern Ireland, along the A1 corridor connecting the two cities of Belfast and Dublin. The structure is on a central route through the island of Ireland and has a high traffic volume which made it an optimum location for the study. Another huge benefit of the chosen location was its close proximity to a nearby self-operated weigh station. To determine the accuracy of the proposed B-WIM system and develop a knowledge base of the traffic load on the structure, a pavement WIM system was also installed on the northbound lane on the approach to the structure. The bridge structure selected for this B-WIM research comprised of 27 pre-cast prestressed concrete Y4-beams, and a cast in-situ concrete deck. The structure, a newly constructed integral bridge, spans 19 m and has an angle of skew of 22.7°.
Resumo:
We describe, for the first time, stimuli-responsive hydrogel-forming microneedle (MN) arrays that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of light. MN arrays were prepared using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) by micromolding. The obtained MN arrays showed good mechanical properties. The system was loaded with up to 5% (w/w) ibuprofen included in a light-responsive 3,5-dimethoxybenzoin conjugate. Raman spectroscopy confirmed the presence of the conjugate inside the polymeric MN matrix. In vitro, this system was able to deliver up to three doses of 50 mg of ibuprofen upon application of an optical trigger over a prolonged period of time (up to 160 hours). This makes the system appealing as a controlled release device for prolonged periods of time. We believe that this technology has potential for use in ?on-demand? delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.