101 resultados para Steam injection.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND:

Plantar fasciitis is a common cause of heel pain. The aim of this study was twofold: to compare steroid injection with placebo injection and to compare ultrasound guided with unguided steroid injection in the management of this condition.

METHODS:

65 patients with inferior heel pain were recruited between November 2008 and June 2011. Heel pain was measured using a visual analogue scale (VAS) at baseline and follow-up 6 and 12 weeks after injection.

RESULTS:

22 patients were randomised to ultrasound guided steroid injection, 21 patients to palpation guided steroid injection and 22 to ultrasound guided placebo injection. There was a significant difference in VAS scores between the groups at 6 and 12 weeks (p=0.018 and p=0.004, respectively). There was a 19.7 (95% CI 2.5 to 37.0) difference in mean VAS scores at 6 weeks between the ultrasound guided steroid group and the placebo group and a 24.0 (95% CI 6.6 to 41.3) difference between the unguided steroid group and the placebo group at 6 weeks. At 12 weeks, the mean difference was 25.1 (95% CI 6.5 to 43.6) and 28.4 (95% CI 11.1 to 45.7) respectively between both steroid injection groups and the placebo group. There was no difference in VAS scores following steroid injection between the ultrasound guided and the unguided groups at either time point. Plantar fascia thickness was significantly reduced after injection in both active treatment groups (p=0.00).

CONCLUSIONS:

In this study, steroid injection showed a clear benefit over placebo at 6 weeks and this difference was maintained at 12 weeks.Trial Registration No ISRCTN79628180 (www.controlled-trials.com).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sustained-release matrix tablets based on Eudragit RL and RS were manufactured by injection moulding. The influence of process temperature; matrix composition; drug load, plasticizer level; and salt form of metoprolol: tartrate (MPT), fumarate (MPF) and succinate (MPS) on ease of processing and drug release were evaluated. Formulations composed of 70/30% Eudragit RL/MPT showed the fastest drug release, substituting part of Eudragit RL by RS resulted in slower drug release, all following first-order release kinetics. Drug load only affected drug release of matrices composed of Eudragit RS: a higher MPT concentration yielded faster release rates. Adding triethyl citrate enhanced the processability, but was detrimental to long-term stability. The process temperature and plasticizer level had no effect on drug release, whereas metoprolol salt form significantly influenced release properties. The moulded tablets had a low porosity and a smooth surface morphology. A plasticizing effect of MPT, MPS and MPF on Eudragit RS and Eudragit RL was observed via DSC and DMA. Solubility parameter assessment, thermal analysis and X-ray diffraction demonstrated the formation of a solid solution immediately after production, in which H-bonds were formed between metoprolol and Eudragit as evidenced by near-infrared spectroscopy. However, high drug loadings of MPS and MPF showed a tendency to recrystallise during storage. The in vivo performance of injection-moulded tablets was strongly dependent upon drug loading. © 2012 American Association of Pharmaceutical Scientists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that mitomycin-C increases the success rate of trabeculectomy; however, a rise in the incidence of postoperative complications has also been reported. Consequently, the use of antimetabolite is usually reserved for patients who are at high risk of surgical failure or for patients with advanced glaucoma in whom low intraocular pressure is desired. This report describes a patient who suffered severe visual loss which was a direct result of hypotonous maculopathy after trabeculectomy with mitomycin-C and various other complications from the subsequent interventions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Co3O4, Fe2O3 and a mixture of the two oxides Co–Fe (molar ratio of Co3O4/Fe2O3 = 0.67 and atomic ratio of Co/Fe = 1) were prepared by the calcination of cobalt oxalate and/or iron oxalate salts at 500 °C for 2 h in static air using water as a solvent/dispersing agent. The catalysts were studied in the steam reforming of ethanol to investigate the effect of the partial substitution of Co3O4 with Fe2O3 on the catalytic behaviour. The reforming activity over Fe2O3, while initially high, underwent fast deactivation. In comparison, over the Co–Fe catalyst both the H2 yield and stability were higher than that found over the pure Co3O4 or Fe2O3 catalysts. DRIFTS-MS studies under the reaction feed highlighted that the Co–Fe catalyst had increased amounts of adsorbed OH/water; similar to Fe2O3. Increasing the amount of reactive species (water/OH species) adsorbed on the Co–Fe catalyst surface is proposed to facilitate the steam reforming reaction rather than decomposition reactions reducing by-product formation and providing a higher H2 yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulations of the injection stretch-blow moulding process have been developed for the manufacture of poly(ethylene terephthalate) bottles using the commercial finite element package ABAQUS/standard. Initially a simulation of the manufacture of a 330 mL bottle was developed with three different material models (hyperelastic, creep, and a non-linear viscoelastic model (Buckley model)) to ascertain their suitability for modelling poly(ethylene terephthalate). The Buckley model was found to give results for the sidewall thickness that matched best with those measured from bottles off the production line. Following the investigation of the material models, the Buckley model was chosen to conduct a three-dimensional simulation of the manufacture of a 2 L bottle. It was found that the model was also capable of predicting the wall thickness distribution accurately for this bottle. In the development of the three-dimensional simulation a novel approach, which uses an axisymmetric model until the material reaches the petaloid base, was developed. This resulted in substantial savings in computing time. © 2000 IoM Communication Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferroelectric domain wall injection has been demonstrated by engineering of the
local electric field, using focused ion beam milled defects in thin single crystal lamellae of KTiOPO4 (KTP). The electric field distribution (top) displays localized field hot-spots, which correlate with nucleation events (bottom). Designed local field variations can also dictate subsequent domain wall mobility, demonstrating a new paradigm in ferroelectric domain wall control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the adverse effect of intravitreal injection of normal saline (NS) and phosphate buffered saline (PBS) in mouse eyes.

Methods: NS or PBS was injected intravitreally into C57BL/6J mouse eyes. Retinal lesions were monitored by fundus imaging, spectral-domain optical coherence tomography (SD-OCT), and histological investigations. Retinal immune gene expression was determined by real-time polymerase chain reaction (PCR). The toxic effect of NS and PBS or retinal protein from NS- or PBS-injected eyes on retinal pigment epithelium (RPE) was tested in B6-RPE-07 mouse RPE cell cultures.

Results: Intravitreal injection of NS dose-dependently induced localized retinal lesion in mice. Histological investigations revealed multiple vacuoles in photoreceptor outer segments and RPE cells. The lesions recovered over time and by 3 weeks post injection the majority of lesions vanished in eyes receiving 1 μl NS. Inflammatory genes, including TNF-α, IL-1β, IL-6, iNOS, and VEGF were upregulated in NS injected eyes. Intravitreal injection of PBS did not cause any pathology. The treatment of B6-RPE07 cells with 30% PBS or 30% NS did not affect RPE viability. However, incubation of 1-μg/ml retinal protein from NS-injected eyes, but not PBS-injected eyes induced RPE cell death.

Conclusion: NS is toxic to the C57BL/6J mouse retina and should not be used as a vehicle for intraocular injection. PBS is not toxic to the retina and is a preferred vehicle.

Translational Relevance: NS is not a physiological solution for intraocular injection in the C57BL/6J mice and questions its suitability for intraocular injection in other species, including human.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the histological features of subcutaneous inflammation induced by mistletoe, a popular Christmas decoration, when used as an anticancer complementary therapy. We also outline the use of extract of mistletoe in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple meso-scale capacitor structures have been made by incorporating thin (300 nm) single crystal lamellae of KTiOPO4 (KTP) between two coplanar Pt electrodes. The influence that either patterned protrusions in the electrodes or focused ion beam milled holes in the KTP have on the nucleation of reverse domains during switching was mapped using piezoresponse force microscopy imaging. The objective was to assess whether or not variations in the magnitude of field enhancement at localised “hot-spots,” caused by such patterning, could be used to both control the exact locations and bias voltages at which nucleation events occurred. It was found that both the patterning of electrodes and the milling of various hole geometries into the KTP could allow controlled sequential injection of domain wall pairs at different bias voltages; this capability could have implications for the design and operation of domain wall electronic devices, such as memristors, in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite adherence to strict standards of care in preparation for intravitreal injections, endophthalmitis can still occur. This article focuses on endophthalmitis and the importance of povidone-iodine in pre-procedure antisepsis. An overview of endophthalmitis and an examination of the benefits of povidone-iodine in ocular aseptic technique for the prevention of post-procedure endophthalmitis are provided. The misconceptions that patients and health practitioners may have in relation to povidone-iodine hypersensitivity are also explored.