82 resultados para Physical and chemical parameters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the results of a Monte Carlo technique to calculate the absolute magnitudes (H) and slope parameters (G) of about 240,000 asteroids observed by the Pan-STARRS1 telescope during the first 15 months of its 3-year all-sky survey mission. The system's exquisite photometry with photometric errors asteroids rotation period, amplitude and color to derive the most-likely H and G, but its major advantage is in estimating realistic statistical+systematic uncertainties and errors on each parameter. The method was confirmed by comparison with the well-established and accurate results for about 500 asteroids provided by Pravec et al. (2012) and then applied to determining H and G for the Pan-STARRS1 asteroids using both the Muinonen et al. (2010) and Bowell et al. (1989) phase functions. Our results confirm the bias in MPC photometry discovered by ( Jurić et al., 2002).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vermiculite minerals are locally available in the Mozambique Belt of Tanzania but are not currently commercially exploited. In part this may be due to lack of any precise characterization. This study was carried out as a first step to assess the suitability of these vermiculites for crop production by characterization of their mineralogical and chemical compositions. X-ray diffraction and scanning electron microscopy combined with an energydispersive X-ray system were used to establish the mineralogy. Electron microprobe analysis and inductively coupled plasma-mass spectrometry were used to study the chemical compositions and to identify any possible issues related to chemical composition that might affect their use if applied as soil conditioners. The samples were characterized as vermiculites and hydrobiotites with a wide variety of accessory minerals. Accessory minerals that might be of some concern are galena, fibrous amphiboles and sepiolite. The total levels of Ni in all vermiculites, and Cr in some, were also found to be high relative to common European standards and this might limit their potential as soil conditioners. It is clear that a field assessment of the bioavailability of various elements would be necessary before decisions relating to potential agricultural use could be made. © 2009 The Mineralogical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several factors affecting the reactivity of pulverised fuel ash (pfa) as a precursor for geopolymer concrete have been investigated. These include physical and chemical properties of various pfa sources, inclusion of ground granulated blast furnace slag (ggbs), chemical activator dosages and curing temperature. Alkali-activated pfa was found to require elevated curing temperatures and high alkali concentrations. A mixture of sodium hydroxide and sodium silicate was used and this was shown to result in high strengths, as high as 70 MPa at 28-days. The presence of silicates in solution was found to be a key factor. Detailed physical and chemical characterisation was carried out on thirteen pfa sources from the UK. The most important factor affecting the reactivity was found to be the particle size of pfa. The loss on ignition (LOI) and the amorphous content are also important parameters that need to be considered for the selection of pfa for use in geopolymer concrete. The partial replacement of pfa by ground granulated blast furnace slag (ggbs) was found to be beneficial in not only avoiding the need for elevated curing temperatures but also in improving compressive strengths. Microstructural characterisation with scanning electron microscope (SEM) coupled with energy dispersive X-ray spectroscopy (EDS) was performed on pfa/ggbs pastes. The reaction product of pfa and ggbs in these binary systems was calcium aluminium silicate hydrate gel (C-A-S-H) with inclusion of Na in the structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selective cell recognition and capture has recently attracted significant interest due to its potential importance for clinical, diagnostic, environmental, and security applications. Current methods for cell isolation from complex samples are largely dependent on cell size and density, with limited application scope as many of the target cells do not exhibit appreciable differences in this respect. The most recent and forthcoming developments in the area of selective recognition and capture of whole cells, based on natural receptors, as well as synthetic materials utilising physical and chemical properties of the target cell or microorganism, are highlighted. Particular focus is given to the development of cell complementary surfaces using the cells themselves as templating agents, by means of molecular imprinting, and their combination with sensing platforms for rapid cell detection in complex media. The benefits and challenges of each approach are discussed and a perspective of the future of this research area is given.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Ca2+ ion is an important intracellular messenger essential for the regulation of various cellular functions including proliferation, differentiation and apoptosis. Transient Receptor Potential (TRP) channels are calcium permeable cationic channels that play important role in regulation of free intracellular calcium ([Ca2+]i) in response to thermal, physical and chemical stimuli. Ca2+ signalling in human dental pulp stem cells (hDPSCs) and the ion channels regulating Ca2+ are largely not known. Objectives: Investigate changes in [Ca2+]i and determine the ion channels that regulate calcium signalling in hDPSCs. Methods: DPSCs were derived from immature third molars and cells less than passage 6 were used in all the experiments. Changes in [Ca2+]i were studied with Fura2 calcium imaging. RNA was extracted from DPSCs and a panel of TRP channel gene expression was determined by qPCR employing custom designed FAM TRP specific primers and probes (Roche, UK) and the Light Cycler 480 Probes Master (Roche). Results: hDPSCs express gene transcripts for all TRP families including TRPV1, V2, V4, TRPA1, TRPC3, TRPC5, TRPC6, TRPM3, TRPM7 and TRPP2. Stimulation of cells with appropriate TRP channel agonist induced increase in [Ca2+]i and similar responses were obtained when cell were mechanically stimulated by membrane stretch with application of hypotonic solution. Conclusion: TRP channels mediate calcium signalling in hDPSCs that merit further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE:

To determine the test-retest variability in perimetric, optic disc, and macular thickness parameters in a cohort of treated patients with established glaucoma.

PATIENTS AND METHODS:

In this cohort study, the authors analyzed the imaging studies and visual field tests at the baseline and 6-month visits of 162 eyes of 162 participant in the Glaucoma Imaging Longitudinal Study (GILS). They assessed the difference, expressed as the standard error of measurement, of Humphrey field analyzer II (HFA) Swedish Interactive Threshold Algorithm fast, Heidelberg retinal tomograph (HRT) II, and retinal thickness analyzer (RTA) parameters between the two visits and assumed that this difference was due to measurement variability, not pathologic change. A statistically significant change was defined as twice the standard error of measurement.

RESULTS:

In this cohort of treated glaucoma patients, it was found that statistically significant changes were 3.2 dB for mean deviation (MD), 2.2 for pattern standard deviation (PSD), 0.12 for cup shape measure, 0.26 mm for rim area, and 32.8 microm and 31.8 microm for superior and inferior macular thickness, respectively. On the basis of these values, it was estimated that the number of potential progression events detectable in this cohort by the parameters of MD, PSD, cup shape measure, rim area, superior macular thickness, and inferior macular thickness was 7.5, 6.0, 2.3, 5.7, 3.1, and 3.4, respectively.

CONCLUSIONS:

The variability of the measurements of MD, PSD, and rim area, relative to the range of possible values, is less than the variability of cup shape measure or macular thickness measurements. Therefore, the former measurements may be more useful global measurements for assessing progressive glaucoma damage.