84 resultados para Passive vibration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active network scanning injects traffic into a network and observes responses to draw conclusions about the network. Passive network analysis works by looking at network meta data or by analyzing traffic as it traverses a fixed point on the network. It may be infeasible or inappropriate to scan critical infrastructure networks. Techniques exist to uniquely map assets without resorting to active scanning. In many cases, it is possible to characterize and identify network nodes by passively analyzing traffic flows. These techniques are considered in particular with respect to their application to power industry critical infrastructure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Double Skin Façades (DSFs) are becoming increasingly popular architecture for commercial office buildings. Although DSFs are widely accepted to have the capacity to offer significant passive benefits and enable low energy building performance, there remains a paucity of knowledge with regard to their operation. Identification of the most determinant architectural parameters of DSFs is the focus of ongoing research. This paper presents an experimental and simulation study of a DSF installed on a commercial building in Dublin, Ireland. The DSF is south facing and acts to buffer the building from winter heat losses, but risks enhancing over-heating on sunny days. The façade is extensively monitored during winter months. Computational Fluid Dynamic (CFD) models are used to simulate the convective operation of the DSF. This research concludes DSFs as suited for passive, low energy architecture in temperature climates such as Ireland but identifies issues requiring attention in DSF design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The X-parameter based nonlinear modelling tools have been adopted as the foundation for the advanced methodology
of experimental characterisation and design of passive nonlinear devices. Based upon the formalism of the Xparameters,
it provides a unified framework for co-design of antenna beamforming networks, filters, phase shifters and
other passive and active devices of RF front-end, taking into account the effect of their nonlinearities. The equivalent
circuits of the canonical elements are readily incorporated in the models, thus enabling evaluation of PIM effect on the
performance of individual devices and their assemblies. An important advantage of the presented methodology is its
compatibility with the industry-standard established commercial RF circuit simulator Agilent ADS.
The major challenge in practical implementation of the proposed approach is concerned with experimental retrieval of the X-parameters for canonical passive circuit elements. To our best knowledge commercial PIM testers and practical laboratory test instruments are inherently narrowband and do not allow for simultaneous vector measurements at the PIM and harmonic frequencies. Alternatively, existing nonlinear vector analysers (NVNA) support X-parameter measurements in a broad frequency bands with a range of stimuli, but their dynamic range is insufficient for the PIM characterisation in practical circuits. Further opportunities for adaptation of the X-parameters methodology to the PIM
characterisation of passive devices using the existing test instruments are explored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The principle aspects of passive intermodulation (PIM) characterisation in distributed printed circuits with cascaded lumped nonlinearities are presented. Mechanisms of PIM generations have been investigated experimentally and modelled using the formalism of X-parameters. The devised equivalent circuit models are applied to the analysis of microstrip lines with distributed and cascaded lumped sources of nonlinearity. The dynamic measurements have revealed that PIM generation rates in straight and meandered microstrip lines differ and significantly deviate from those expected for the respective discrete sources of nonlinearity. The obtained results indicate that multiple physical sources of nonlinearity contribute to PIM generation in printed circuits. Finally, it is demonstrated that the electrical discontinuities can have significant effect on the overall PIM response of the distributed passive circuits and cause PIM product leakage and parasitic coupling between isolated circuit elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents initial results of evaluating suitability of the conventional two-tone CW passive intermodulation (PIM) test for characterization of modulated signal distortion by passive nonlinearities in base station antennas and RF front-end. A comprehensive analysis of analog and digitally modulated waveforms in the transmission lines with weak distributed nonlinearity has been performed using the harmonic balance analysis and X-parameters in Advanced Design System (ADS) simulator. The nonlinear distortion metrics used in the conventional two-tone CW PIM test have been compared with the respective spectral metrics applied to the modulated waveforms, such as adjacent channel power ratio (ACPR) and error vector magnitude (EVM). It is shown that the results of two-tone CW PIM tests are consistent with the metrics used for assessment of signal integrity of both analog and digitally modulated waveforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During extreme sea states so called impact events can be observed on the wave energy converter Oyster. In small scale experimental tests these impact events cause high frequency signals in the measured load which decrease confidence in the data obtained. These loads depend on the structural dynamics of the model. Amplification of the loads can occur and is transferred through the structure from the point of impact to the load cell located in the foundation. Since the determination of design data and load cases for Wave Energy Converters originate from scale experiments, this lack of confidence has a direct effect on the development.

Numerical vibration analysis is a valuable tool in the research of the structural load response of Oyster to impact events, but must take into account the effect of the surrounding water. This can be done efficiently by adding an added mass distribution, computed with a linearised potential boundary element method. This paper presents the development and validation of a numerical procedure, which couples the OpenSource boundary element code NEMOH with the Finite Element Analysis tool CodeAster. Numerical results of the natural frequencies and mode shapes of the structure under the influence of added mass due to specific structural modes are compared with experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passive intermodulation (PIM) often limits the performance of communication systems with analog and digitally-modulated signals and especially of systems supporting multiple carriers. Since the origins of the apparently multiple physical sources of nonlinearity causing PIM are not fully understood, the behavioral models are frequently used to describe the process of PIM generation. In this paper a polynomial model of memoryless nonlinearity is deduced from PIM measurements of a microstrip line with distributed nonlinearity with two-tone CW signals. The analytical model of nonlinearity is incorporated in Keysight Technology’s ADS simulator to evaluate the metrics of signal fidelity in the receive band for analog and digitally-modulated signals. PIM-induced distortion and cross-band interference with modulated signals are compared to those with two-tone CW signals. It is shown that conventional metrics can be applied to quantify the effect of distributed nonlinearities on signal fidelity. It is found that the two-tone CW test provides a worst-case estimate of cross-band interference for two-carrier modulated signals whereas with a three-carrier signal PIM interference in the receive band is noticeably overestimated. The simulated constellation diagrams for QPSK signals demonstrate that PIM interference exhibits the distinctive signatures of correlated distortion and this indicates that there are opportunities for mitigating PIM interference and that PIM interference cannot be treated as noise. One of the interesting results is that PIM distortion on a transmission line results in asymmetrical regrowth of output PIM interference for modulated signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Passive intermodulation (PIM) often limits the performance of communication systems, particularly in the presence of multiple carriers. Since the origins of the apparently multiple physical sources of nonlinearity causing PIM in distributed circuits are not fully understood, the behavioural models are frequently employed to describe the process of PIM generation. In this paper, a memoryless nonlinear polynomial model, capable of predicting high-order multi-carrier intermodulation products, is deduced from the third-order two-tone PIM measurements on a microstrip transmission line with distributed nonlinearity. The analytical model of passive distributed nonlinearity is implemented in Keysight Technology’s ADS simulator to evaluate the adjacent band power ratio for three-tone signals. The obtained results suggest that the costly multi-carrier test setups can possibly be replaced by a simulation tool based on the properly retrieved nonlinear polynomial model.