115 resultados para Measure Vertebral Rotation
Resumo:
Many international business (IB) studies have used foreign direct investment (FDI) stocks to measure the aggregate value-adding activity of multinational enterprises (MNE) affiliates in host countries. We argue that FDI stocks are a biased measure of that activity, because the degree to which they overestimate or underestimate affiliate activity varies systematically with host-country characteristics. First, most FDI into countries that serve as tax havens generate no actual productive activity; thus FDI stocks in such countries overestimate affiliate activity. Second, FDI stocks do not include locally raised external funds, funds widely used in countries with well-developed financial markets or volatile exchange rates, resulting in an underestimation of affiliate activity in such countries. Finally, the extent to which FDI translates into affiliate activity increases with affiliate labor productivity, so in countries where labor is more productive, FDI stocks also result in an underestimation of affiliate activity. We test these hypotheses by first regressing affiliate value-added and affiliate sales on FDI stocks to calculate a country-specific mismatch, and then by regressing this mismatch on a host country's tax haven status, level of financial market development, exchange rate volatility, and affiliate labor productivity. All hypotheses are supported, implying that FDI stocks are a biased measure of MNE affiliate activity, and hence that the results of FDI-data-based studies of such activity need to be reconsidered. [ABSTRACT FROM AUTHOR]
Resumo:
Solar array rotation mechanism provides a hinged joint between the solar panel and satellite body, smooth rota-tion of the solar array into deployed position and its fixation in this position. After unlocking of solar panel (while in orbit), rotation bracket turns towards ready-to-work position under the action of driving spring. During deployment, once reached the required operating angle (defined by power subsystem engineer), the rotation bracket collides with the fixed bracket that is mounted on body of the satellite, to stop rotation. Due to the effect of collision force that may alter the rotation mechanism function, design of centrifugal brake is essential. At stoppage moment micro-switches activate final position sensor and a stopper locks the rotation bracket. Design of spring and centrifugal brake components, static finite element stress analysis of primary structure body of rotation mechanism at stoppage moment have been obtained. Last, reliability analysis of rotation mechanism is evaluated. The benefit of this study is to aid in the design of rotation mechanism that can be used in micro-satellite applications.
Resumo:
Solar array rotation mechanism provides a hinged joint between the solar panel and satellite body, smooth rotation of the solar array into deployed position and its fixation in this position. After unlocking of solar panel (while in orbit), rotation bracket turns towards ready-to-work position under the action of driving spring. During deployment, once reached the required operating angle (defined by power subsystem engineer), the rotation bracket collides with the fixed bracket that is mounted on body of the satellite, to stop rotation. Due to the effect of collision force that may alter the rotation mechanism function, design of centrifugal brake is essential. At stoppage moment micro-switches activate final position sensor and a stopper locks the rotation bracket. Design of spring and centrifugal brake components, static finite element stress analysis of primary structure body of rotation mechanism at stoppage moment have been obtained. Last, reliability analysis of rotation mechanism is evaluated. The benefit of this study is to aid in the design of rotation mechanism that can be used in micro-satellite applications.
Resumo:
Diverse parameters, including chaotropicity, can limit the function of cellular systems and thereby determine the extent of Earth's biosphere. Whereas parameters such as temperature, hydrophobicity, pressure, pH, Hofmeister effects, and water activity can be quantified via standard scales of measurement, the chao-/kosmotropic activities of environmentally ubiquitous substances have no widely accepted, universal scale. We developed an assay to determine and quantify chao-/kosmotropicity for 97 chemically diverse substances that can be universally applied to all solutes. This scale is numerically continuous for the solutes assayed (from +361kJkg-1mol-1 for chaotropes to -659kJkg-1mol-1 for kosmotropes) but there are key points that delineate (i) chaotropic from kosmotropic substances (i.e. chaotropes =+4; kosmotropes =-4kJkg-1mol-1); and (ii) chaotropic solutes that are readily water-soluble (log P<1.9) from hydrophobic substances that exert their chaotropic activity, by proxy, from within the hydrophobic domains of macromolecular systems (log P>1.9). Examples of chao-/kosmotropicity values are, for chaotropes: phenol +143, CaCl2 +92.2, MgCl2 +54.0, butanol +37.4, guanidine hydrochloride +31.9, urea +16.6, glycerol [>6.5M] +6.34, ethanol +5.93, fructose +4.56; for kosmotropes: proline -5.76, sucrose -6.92, dimethylsulphoxide (DMSO) -9.72, mannitol -6.69, trehalose -10.6, NaCl -11.0, glycine -14.2, ammonium sulfate -66.9, polyethylene glycol- (PEG-)1000 -126; and for relatively neutral solutes: methanol, +3.12, ethylene glycol +1.66, glucose +1.19, glycerol [<5M] +1.06, maltose -1.43 (kJkg-1mol-1). The data obtained correlate with solute interactions with, and structure-function changes in, enzymes and membranes. We discuss the implications for diverse fields including microbial ecology, biotechnology and astrobiology.
Resumo:
THE MACHINIST LANDSCAPE: AN ENTROPIC GRID OF VARIANCE
‘By drawing a diagram, a ground plan of a house, a street plan to the location of a site, or a topographic map, one draws a “logical two dimensional picture”. A “logical picture” differs from a natural or realistic picture in that it rarely looks like the thing it stands for.’
A Provisional Theory of Non-Sites, Robert Smithson (1968)
Between design and ground there are variances, deviations and gaps. These exist as physical interstices between what is conceptualised and what is realised; and they reveal moments in the design process that resist the reconciliation of people and their environment (McHarg 1963). The Machinist Landscape interrogates the significance of these variances through the contrasting processes of coppice and photovoltaic energy. It builds on the potential of these gaps, and in doing so proposes that these spaces of variance can reveal the complexity of relationships between consumption and remediation, design and nature.
Fresh Kills Park, and in particular the draft master plan (2006), offers a framework to explore this artificial construct. Central to the Machinist Landscape is the analysis of the landfill gas collection system, planned on a notional 200ft grid. Variations are revealed between this diagrammatic grid measure and that which has been constructed on the site. These variances between the abstract and the real offer the Machinist Landscape a powerful space of enquiry. Are these gaps a result of unexpected conditions below ground, topographic nuances or natural phenomena? Does this space of difference, between what is planned and what is constructed, have the potential to redefine the dynamic processes and relations with the land?
The Machinist Landscape is structured through this space of variance with an ‘entropic grid’, the under-storey of which hosts a carefully managed system of short-rotation coppice (SRC). The coppice, a medieval practice related to energy, product, and space, operates on theoretical and programmatic levels. It is planted along a structure of linear bunds, stabilized through coppice pole retaining structures and enriched with nutrients from coppice produced bio-char. Above the coppice is built an upper-storey of photovoltaic (PV); its structures fabricated from the coppiced timber and the PV produced with graphene from coppice charcoal processes.
Resumo:
Emission line fluxes from cool stars are widely used to establish an apparent emission measure distribution, EmdApp(Te), between temperatures characteristic of the low transition region and the low corona. The true emission measure distribution, EmdTrue(Te), is determined by the energy balance and geometry adopted and, with a numerical model, can be used to predict EmdApp(Te), to guide further modelling. The scaling laws that exist between coronal parameters arise from the dimensions of the terms in the energy balance equation. Here, analytical approximations to numerical solutions for EmdTrue(Te) are presented, which show how the constants in the coronal scaling laws are determined. The apparent emission measure distributions show a minimum value at some T0 and a maximum at the mean coronal temperature Tc (although in some stars, emission from active regions can contribute). It is shown that, for the energy balance and geometry adopted, the analytical values of the emission measure and electron pressure at T0 and Tc depend on only three parameters: the stellar surface gravity and the values of T0 and Tc. The results are tested against full numerical solutions for e Eri (K2 V) and are applied to Procyon (a CMi, F5 IV/V). The analytical approximations can be used to restrict the required range of full numerical solutions, to check the assumed geometry and to show where the adopted energy balance may not be appropriate. © 2011 The Authors Monthly Notices of the Royal Astronomical Society © 2011 RAS.
Resumo:
The rotavirus (RV) inner capsid protein VP6 is widely used to evaluate immune response during natural infection and in vaccine studies. Recombinant VP6 from the most prevalent circulating rotavirus strains in each subgroup (SG) identified in a birth cohort of children in southern India [SGII (G1P[8]) and SGI (G10P[11])] were produced. The purified proteins were used to measure VP6-specific antibodies in a Dissociation-Enhanced Lanthanide Fluorometric Immunoassay (DELFIA). The ability of the assay to detect a =2 fold rise in IgG level in a panel of serum samples from a longitudinal study was compared to a gold standard virus-capture ELISA. A strong association was observed between the assays (p
Resumo:
Researchers and clinicians have experienced substantial difficulties locating measures that are suitable for use within palliative care settings. This article details the psychometric properties of nine instruments designed to assess the following psychosocial characteristics of family caregivers: competence, mastery, self-efficacy, burden, optimism, preparedness, social support, rewards, and mutuality. Results are based on the responses of 106 primary family caregivers caring for relatives dying of cancer. Principal components extraction with varimax rotation was used to explore the underlying structure of each measure. Following the exclusion of complex variables, suggested components for most measures comprised relatively homogenous items, which were good to excellent measures of each component. Some components comprised only two items; however, Cronbach's alphas typically indicated moderate to high levels of internal consistency. Overall, the results of this study suggest that most of the measures analyzed, excepting the mastery and mutuality scales, can be recommended to examine the family caregiver experience and test supportive interventions.
Resumo:
Steady simulations were performed to investigate tip leakage flow and heat transfer characteristics on the rotor blade tip and casing in a single-stage gas turbine engine. A typical high-pressure gas turbine stage was modeled with a pressure ratio of 3.2. The predicted isentropic Mach number and adiabatic wall temperature on the casing showed good agreement with available experimental data under similar operating condition. The present numerical study focuses extensively on the effects of tip clearance heights and rotor rotational speeds on the blade tip and casing heat transfer characteristics. It was observed that the tip leakage flow structure is highly dependent on the height of the tip gap and the speed of the rotor. In all cases, the tip leakage flow was seen to separate and recirculate just around the corner of the pressure side of the blade tip. This region of re-circulating flow enlarges with increasing clearance heights. The separated leakage flow reattaches afterwards on the tip surface. Leakage flow reattachment was shown to enhance surface heat transfer at the tip. The interaction between tip leakage flow and secondary flows that is induced by the relative casing motion is found to significantly influence the blade tip and casing heat transfer distribution. A region of critical heat transfer exists on the casing near the blade tip leading edge and along the pressure-side edge for all the clearance heights that were investigated. At high rotation speed, the region of critical heat transfer tends to move towards the trailing edge due to the change in inflow angle.
Resumo:
The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.
Resumo:
We show how our recently proposed scheme for the measurement of the micromaser linewidth, which relates the phase diffusion dynamics of the cavity field to the population statistics of probe atoms, can be applied in the presence of trapping states, where the phase diffusion approximation does not strictly hold. This should allow the observation of the peculiar linewidth oscillations versus atomic pumping which are expected in this regime, and whose origin lies in the quantum nature of the cavity field.
Resumo:
We propose a realistic scheme for measuring the micromaser linewidth by monitoring the phase diffusion dynamics of the cavity field. Our strategy consists of exciting an initial coherent state with the same photon number distribution as the micromaser steady-state field, singling out a purely diffusive process in the system dynamics. After the injection of a counterfield, measurements of the population statistics of a probe atom allow us to derive the micromaser linewidth in all ranges of the relevant parameters, establishing experimentally the distinctive features of the micromaser spectrum due to the discreteness of the electromagnetic field.