158 resultados para Mean intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the feasibility of a randomized-controlled trial (RCT) investigating the effects of adding auricular acupuncture (AA) to exercise for participants with chronic low-back pain (CLBP). Methods: Participants with CLBP were recruited from primary care and a university population and were randomly allocated (n=51) to 1 of 2 groups: (1) "Exercise Alone (E)"-12-week program consisting of 6 weeks of supervised exercise followed by 6 weeks unsupervised exercise (n=27); or (2) "Exercise and AA (EAA)"-12-week exercise program and AA (n=24). Outcome measures were recorded at baseline, week 8, week 13, and 6 months. The primary outcome measure was the Oswestry Disability Questionnaire. Results: Participants in the EAA group demonstrated a greater mean improvement of 10.7% points (95% confidence interval, -15.3,-5.7) (effect size=1.20) in the Oswestry Disability Questionnaire at 6 months compared with 6.7% points (95% confidence interval, -11.4,-1.9) in the E group (effect size=0.58). There was also a trend towards a greater mean improvement in quality of life, LBP intensity and bothersomeness, and fear-avoidance beliefs in the EAA group. The dropout rate for this trial was lower than anticipated (15% at 6 mo), adherence with exercise was similar (72% E; 65% EAA). Adverse effects for AA ranged from 1% to 14% of participants. Discussion: Findings of this study showed that a main RCT is feasible and that 56 participants per group would need to be recruited, using multiple recruitment approaches. AA was safe and demonstrated additional benefits when combined with exercise for people with CLBP, which requires confirmation in a fully powered RCT.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the innovation process has become more open and networked, Government policy in the UK has sought to promote both research excellence in the university sector and the translation of this into economic benefit through university–business engagement. However, this policy approach has tended to be applied uniformly with little account for organisational differences within the sector. In this paper we consider if differences between universities in their research performance is reflected in their knowledge transfer activity. Specifically, as universities develop a commercialization agenda are the strategic priorities for knowledge transfer, the organisational supports in place to facilitate knowledge transfer and the scale and scope of knowledge transfer activity different for high research intensive (HRI) and low research intensive (LRI) universities? The findings demonstrate that universities’ approach to knowledge transfer is shaped by institutional and organisational resources, in particular their ethos and research quality, rather than the capability to undertake knowledge transfer through a Technology Transfer Office (TTO). Strategic priorities for knowledge transfer are reflected in activity, in terms of the dominance of specific knowledge transfer channels, the partners with which universities engage and the geography of business engagement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion acceleration resulting from the interaction of ultra-high intensity (2 x 10(20) W/cm(2)) and ultra-high contrast (similar to 10(10)) laser pulses with 0.05-10 mu m thick Al foils at normal (0 degrees) and 35 degrees laser incidence is investigated. When decreasing the target thickness from 10 mu m down to 0.05 mu m, the accelerated ions become less divergent and the ion flux increases, particularly at normal (0 degrees) laser incidence on the target. A laser energy conversion into protons of,similar to 6.5% is estimated at 35 degrees laser incidence. Experimental results are in reasonable agreement with theoretical estimates and can be a benchmark for further theoretical and computational work. (C) 2011 American Institute of Physics. [doi:10.1063/1.3643133]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Acute ankle sprains are usually managed functionally, with advice to undertake progressive weight-bearing and walking. Mechanical loading is an important modular of tissue repair; therefore, the clinical effectiveness of walking after ankle sprain may be dose dependent. The intensity, magnitude and duration of load associated with current functional treatments for ankle sprain are unclear.

AIM: To describe physical activity (PA) in the first week after ankle sprain and to compare results with a healthy control group.

METHODS: Participants (16-65 years) with an acute ankle sprain were randomised into two groups (standard or exercise). Both groups were advised to apply ice and compression, and walk within the limits of pain. The exercise group undertook additional therapeutic exercises. PA was measured using an activPAL accelerometer, worn for 7 days after injury. Comparisons were made with a non-injured control group.

RESULTS: The standard group were significantly less active (1.2 ± 0.4 h activity/day; 5621 ± 2294 steps/day) than the exercise (1.7 ± 0 .7 h/day, p=0.04; 7886 ± 3075 steps/day, p=0.03) and non-injured control groups (1.7 ± 0.4 h/day, p=0.02; 8844 ± 2185 steps/day, p=0.002). Also, compared with the non-injured control group, the standard and exercise groups spent less time in moderate (38.3 ± 12.7 min/day vs 14.5 ± 11.4 min/day, p=0.001 and 22.5 ± 15.9 min/day, p=0.003) and high-intensity activity (4.1 ± 6.9 min/day vs 0.1 ± 0.1 min/day, p=0.001 and 0.62 ± 1.0 min/day p=0.005).

CONCLUSION: PA patterns are reduced in the first week after ankle sprain, which is partly ameliorated with addition of therapeutic exercises. This study represents the first step towards developing evidence-based walking prescription after acute ankle sprain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen's University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 10(9) Gy s(-1) and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study objective: To examine the relation between work stress, as indicated by the job strain model, and the effort-reward imbalance model, and smoking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Co-localisation is a widely used measurement in immunohistochemical analysis to determine if fluorescently labelled biological entities, such as cells, proteins or molecules share a same location. However the measurement of co-localisation is challenging due to the complex nature of such fluorescent images, especially when multiple focal planes are captured. The current state-of-art co-localisation measurements of 3-dimensional (3D) image stacks are biased by noise and cross-overs from non-consecutive planes.

Method: In this study, we have developed Co-localisation Intensity Coefficients (CICs) and Co-localisation Binary Coefficients (CBCs), which uses rich z-stack data from neighbouring focal planes to identify similarities between image intensities of two and potentially more fluorescently-labelled biological entities. This was developed using z-stack images from murine organotypic slice cultures from central nervous system tissue, and two sets of pseudo-data. A large amount of non-specific cross-over situations are excluded using this method. This proposed method is also proven to be robust in recognising co-localisations even when images are polluted with a range of noises.

Results: The proposed CBCs and CICs produce robust co-localisation measurements which are easy to interpret, resilient to noise and capable of removing a large amount of false positivity, such as non-specific cross-overs. Performance of this method of measurement is significantly more accurate than existing measurements, as determined statistically using pseudo datasets of known values. This method provides an important and reliable tool for fluorescent 3D neurobiological studies, and will benefit other biological studies which measure fluorescence co-localisation in 3D.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context. Radiative transfer calculations have predicted intensity enhancements for optically thick emission lines, as opposed to the normal intensity reductions, for astrophysical plasmas under certain conditions. In particular, the results are predicted to be dependent both on the geometry of the emitting plasma and the orientation of the observer. Hence in principle the detection of intensity enhancement may provide a way of determining the geometry of an unresolved astronomical source.
Aims. To investigate such enhancements we have analysed a sample of active late-type stars observed in the far ultraviolet spectral region.
Methods. Emission lines of O vi in the FUSE satellite spectra of ϵ Eri, II Peg and Prox Cen were searched for intensity enhancements due to opacity.
Results. We have found strong evidence for line intensity enhancements due to opacity during active or flare-like activity for all three stars. The O vi 1032/1038 line intensity ratios, predicted to have a value of 2.0 in the optically thin case, are found to be up to ~30% larger during several orbital phases.
Conclusions. Our measurements, combined with radiative transfer models, allow us to constrain both the geometry of the O vi emitting regions in our stellar sources and the orientation of the observer. A spherical emitting plasma can be ruled out, as this would lead to no intensity enhancement. In addition, the theory tells us that the line-of-sight to the plasma must be close to perpendicular to its surface, as observations at small angles to the surface lead to either no intensity enhancement or the usual line intensity decrease over the optically thin value. For the future, we outline a laboratory experiment, that could be undertaken with current facilities, which would provide an unequivocal test of predictions of line intensity enhancement due to opacity, in particular the dependence on plasma geometry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The initial kinetics of the oxidation of 4-chlorophenol, 4-CP, photocatalyzed by titania films and aqueous dispersions were studied as a function of oxygen partial pressure, P-O2, and incident light intensity, I. The reaction conditions were such that the kinetics were independent of [4-CP] but strongly dependent on PO2-a situation that allowed investigation of the less-often studied kinetics of oxygen reduction. The observed kinetics fit a pseudo-steady-state model in which the oxygen is Langmuir-adsorbed on the titania photocatalyst particles before being reduced by photogenerated electrons. The maximum rate of photocatalysis depends directly on I-beta, where, beta = 1 for films and 0.7 for dispersions of titania, indicating that the kinetics are dominated by the surface reactions of the photogenerated electrons and holes for the films and by direct recombination for the powder dispersions. Using the pseudo-first-order model, for both titania films and dispersions, the apparent Langmuir adsorption constant, K-LH, derived from a Langmuir-Hinshelwood analysis of the kinetics, appears to be largely independent of incident light intensity, unlike KLH for 4-CP Consequently, similar values are obtained for the Langmuir adsorption constant, K-ads, extracted from a pseudosteady-state analysis of the kinetics for oxygen on TiO2 dispersions and films in aqueous solution (i.e., ca. 0.0265 +/- 0.005 kPa(-1)), and for both films and dispersions, oxygen appears to be weakly adsorbed on TiO2 compared with 4-CP, at a rate that would take many minutes to reach equilibrium. The value of Kads for oxygen on titania particles dispersed in solution is ca. 4.7 times lower than that reported for the dark Langmuir adsorption isotherm; possible causes for this difference are discussed. (c) 2006 Elsevier Inc. All rights reserved.