165 resultados para Liesegang rings
Resumo:
Background: Small molecule inhibitors of the zinc finger domain (ZFI) in the nucleocapsid protein (NCp7) of HIV-1 are potent inhibitors of HIV and SIV
replication and may have utility as topical products to prevent infection. Furthermore, intravaginal rings (IVRs) were developed as coitally-independent,
sustained release devices which could be used for administration of HIV microbicides. The aims of these studies were to demonstrate that IVRs sized for
macaques are practical and compatible with the current generation of thioester-based NCp7 inhibitors.
Methods: Non-medicated silicone elastomer vaginal rings of various sizes thought to be applicable for macaques were prepared and tested for vaginal fit in Pigtailed and Chinese Rhesus macaques. Macaques were monitored for 8 weeks for mucosal disruption by colposcopy and proinflammatory cytokine markers in cervical vaginal lavages (CVL) using Luminex bead-based technology. Three different ZFIs (compounds 52, 89 and 122, each derived from an N-substituted S-acyl-2-mercaptobenzamide thioester scaffold) were loaded at 50 mg into an optimal matrix-type ring design. In vitro continuous release studies were then conducted over 28 days and analyzed by HPLC. Rate of release was determined by linear regression analysis.
Results: Qualitative evaluation at the time of ring insertion suggested that the 25 mm ring provided optimal fit in both macaque species. All rings remained in
place during the study period (2 to 4 weeks), and the animals did not attempt to remove the rings. No tissue irritation was observed, and no signs of physical
discomfort were noted. Also, no significant induction of cervicovaginal proinflammatory markers was observed during the 8-week period during and following ring insertion. One Pigtailed macaque showed elevated IL-8 levels in the CVL during the period when the ring was in place; however, these levels were comparable to those observed in two control macaques. In vitro release of the ZFIs peaked at day 1 and then continually declined to near steady-state rates between 20-30 mcg/day. The percent release after 14 days was 2.9, 2.0 and 0.9 for ZFI 89, 52 and 122, respectively.
Conclusions: IVRs of 25mm diameter, determined to be the optimal size for macaques, were well tolerated and did not induce inflammation. Release of all ZFI compounds followed t 0.5 kinetics. These findings suggest that efficacy testing in primate models is warranted to fully evaluate the potential to prevent
transmission.
Resumo:
Cervical cancer is the third most prevalent cancer in women and disproportionately affects those in low resource settings due to limited programs for screening and prevention. In the developed world treatment for the disease in the non-metastasised state usually takes the form of surgical intervention and/or radiotherapy. In the developing world such techniques are less widely available. This paper describes the development of an intravaginal ring for the localised delivery of a chemotherapeutic drug to the cervix that has the potential to reduce the need for surgical intervention and will also provide a novel anti-cancer therapy for women in low resource settings. Disulfiram has demonstrated antineoplastic action against prostate, breast and lung cancer. Both PEVA and silicone elastomer were investigated for suitability as materials in the manufacture of DSF eluting intravaginal rings. DSF inhibited the curing process of the silicone elastomer, therefore PEVA was chosen as the material to manufacture the DSF-loaded vaginal rings. The vaginal rings had an excellent content uniformity while the DSF remained stable throughout the manufacturing process. Furthermore, the rings provided diffusion controlled release of DSF at levels well in excess of the IC50 value for the HeLa cervical cancer cell line.
Resumo:
Let C be a bounded cochain complex of finitely generatedfree modules over the Laurent polynomial ring L = R[x, x−1, y, y−1].The complex C is called R-finitely dominated if it is homotopy equivalentover R to a bounded complex of finitely generated projective Rmodules.Our main result characterises R-finitely dominated complexesin terms of Novikov cohomology: C is R-finitely dominated if andonly if eight complexes derived from C are acyclic; these complexes areC ⊗L R[[x, y]][(xy)−1] and C ⊗L R[x, x−1][[y]][y−1], and their variants obtainedby swapping x and y, and replacing either indeterminate by its inverse.
Resumo:
Background: Following progress of the dapivirine (DPV)-releasing silicone elastomer (SE) vaginal ring (VR) into Phase III clinical studies, there is now interest in developing next-generation rings that additionally provide contraception. Levonorgestrel (LNG) is a safe and effective progestin that is being widely considered for use as a hormonal contraceptive agent in future multipurpose prevention technology (MPT) products. Although LNG has previously been incorporated into various controlled release SE devices, minimal attention has focused on its propensity to irreversibly react with addition cure SE systems. Here, for the first time, we investigate this LNG binding phenomenon and outline strategies for overcoming it.
Methods: VRs containing various loadings of DPV and LNG were manufactured and in vitro release assessed. Different LNG-only SE samples were also prepared to assess the following parameters: (i) addition cure vs. condensation cure SEs; (ii) different types of addition cure SEs; (iii) mixing time, (iv) cure temperature, (v) cure time; and (vi) LNG particle size. After manufacture, the LNG-only samples were assayed for total drug content using a solvent extraction method. The SE curing reaction and the LNG binding reaction was probed using nuclear magnetic resonance (NMR) spectroscopy. Results:
Under certain drug/formulation/processing conditions, LNG was not recoverable from VRs. Further studies using non-ring samples showed that: (a) the phenomenon was only observed with addition cure SEs (and not condensation cure SEs); (b) the extent of binding was dependent upon the type of addition cure SE; (c) micronised LNG showed significantly greater binding than non-micronised LNG; (d) the extent of binding correlated with increased mixing time, cure time and cure temperature.
Conclusions: Careful control of the API characteristics, the SE composition, and the manufacturing conditions will be necessary to establish a practical VR formulation for controlled release of LNG.
Resumo:
We present a homological characterisation of those chain complexes of modules over a Laurent polynomial ring in several indeterminates which are finitely dominated over the ground ring (that is, are a retract up to homotopy of a bounded complex of finitely generated free modules). The main tools, which we develop in the paper, are a non-standard totalisation construction for multi-complexes based on truncated products, and a high-dimensional mapping torus construction employing a theory of cubical diagrams that commute up to specified coherent homotopies.
Resumo:
Vaginal rings (VRs) are flexible, torus-shaped, polymeric devices designed to sustain delivery of pharmaceutical drugs to the vagina for clinical benefit. Following first report in a 1970 patent application, several steroid-releasing VR products have since been marketed for use in hormone replacement therapy and contraception. Since 2002, there has been growing interest in the use of VR technology for delivery of drugs that can reduce the risk of sexual acquisition of human immunodeficiency virus type 1 (HIV-1), the causative agent of acquired immunodeficiency syndrome (AIDS). Although no vaginally-administered product has yet been approved for HIV reduction/prevention, extensive research efforts are continuing and a number of VR devices offering sustained release of so-called ‘HIV microbicide’ compounds are currently being evaluated in late-stage clinical studies. This review article provides an overview of the published scientific literature within this important field of research, focusing primarily on articles published within peer-reviewed journal publications. Many important aspects of microbicide-releasing VR technology are discussed, with a particular emphasis on the technological, manufacturing and clinical challenges that have emerged in recent years.