98 resultados para Hip hop


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study focuses on the effect of the material type and the lubricant on the abrasive wear behaviour of two important commercially available ceramic on ceramic prosthetic systems, namely, Biolox(R) forte and Bioloxl(R) delta (CeramTec AG, Germany). A standard microabrasion wear apparatus was used to produce '3-body' abrasive wear scars with three different lubricants: ultrapure water, 25 vol% new-born calf serum solution and 1 wt% carboxymethyl cellulose sodium salt (CMC-Na) solution. 1 mu m alumina particles were used as the abrasive. The morphology of the wear scar was examined in detail using Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). Subsurface damage accumulation was investigated by Focused Ion Beam (FIB) cross-sectional milling and Transmission Electron Microscopy (TEM). The effect of the lubricant on the '3-body' abrasive wear mechanisms is discussed and the effect of material properties compared. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first planet discovery from the two-wheeled Kepler (K2) mission: HIP 116454 b. The host star HIP 116454 is a bright (V = 10.1, K = 8.0) K1 dwarf with high proper motion and a parallax-based distance of 55.2 +/- 5.4 pc. Based on high-resolution optical spectroscopy, we find that the host star is metal-poor with [Fe/H]= -0.16 +/- 0.08 and has a radius R-star = 0.716 +/- 0.024 R-circle dot and mass M-star = 0.775 +/- 0.027M(circle dot). The star was observed by the Kepler spacecraft during its Two-Wheeled Concept Engineering Test in 2014 February. During the 9 days of observations, K2 observed a single transit event. Using a new K2 photometric analysis technique, we are able to correct small telescope drifts and recover the observed transit at high confidence, corresponding to a planetary radius of R-p = 2.53 +/- 0.18 R-circle plus. Radial velocity observations with the HARPS-N spectrograph reveal a 11.82 +/- 1.33 M-circle plus planet in a 9.1 day orbit, consistent with the transit depth, duration, and ephemeris. Follow-up photometric measurements from the MOST satellite confirm the transit observed in the K2 photometry and provide a refined ephemeris, making HIP 116454 b amenable for future follow-up observations of this latest addition to the growing population of transiting super-Earths around nearby, bright stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hip replacement surgery is amongst the most common orthopaedic operations performed in the UK. Aseptic loosening is responsible for 40% of hip revision procedures. Aseptic loosening is a result of cement mantle fatigue. The aim of the current study is to analyse the effect of nanoscale Graphene Oxide (GO) on the mechanical properties of orthopaedic bone cement. Study Design A experimental thermal and mechanical analysis was conducted in a laboratory set up conforming to international standards for bone cement testing according to ISO 5583. Testing was performed on control cement samples of Colacryl bone cement, and additional samples reinforced with variable wt% of Graphene Oxide containing composites – 0.1%, 0.25%, 0.5% and 1.0% GO loading. Pilot Data Porosity demonstrated a linear relationship with increasing wt% loading compared to control (p<0.001). Thermal characterisation demonstrated maximal temperature during polymerization, and generated exotherm were inversely proportional to w%t loading (p<0.05) Fatigue strength performed on the control and 0.1 and 0.25%wt loadings of GO demonstrate increased average cycles to failure compared to control specimens. A right shift of the Weibull curve was demonstrated for both wt% available currently. Logistic regression analysis for failure demonstrated significant increases in number of cycles to failure for both specimens compared to a control (p<0.001). Forward Plan Early results convey positive benefits at low wt% loadings of GO containing bone cement. Study completion and further analysis is required in order to elude to the optimum w%t of GO which conveys the greatest mechanical advantage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a thorough performance analysis of dual-hop cognitive amplify-and-forward (AF) relaying networks under spectrum-sharing mechanism over independent non-identically distributed (i.n.i.d.) &#x100000; fading channels. In order to guarantee the quality-of-service (QoS) of primary networks, both maximum tolerable peak interference power Q at the primary users (PUs) and maximum allowable transmit power P at secondary users (SUs) are considered to constrain transmit power at the cognitive transmitters. For integer-valued fading parameters, a closed-form lower bound for the outage probability (OP) of the considered networks is obtained. Moreover, assuming arbitrary-valued fading parameters, the lower bound in integral form for the OP is derived. In order to obtain further insights on the OP performance, asymptotic expressions for the OP at high SNRs are derived, from which the diversity/coding gains and the diversity-multiplexing gain tradeoff (DMT) of the secondary network can be readily deduced. It is shown that the diversity gain and also the DMT are solely determined by the fading parameters of the secondary network whereas the primary network only affects the coding gain. The derived results include several others available in previously published works as special cases, such as those for Nakagami-m fading channels. In addition, performance evaluation results have been obtained by Monte Carlo computer simulations which have verified the accuracy of the theoretical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the performance of amplify-and-forward dual-hop relaying systems in the presence of in-phase and quadrature-phase imbalance (IQI) at the relay node. In particular, an exact analytical expression for and tight lower bounds on the outage probability are derived over independent, non-identically distributed Nakagami-m fading channels. Moreover, tractable upper and lower bounds on the ergodic capacity are presented at arbitrary signal-to-noise ratios (SNRs). Some special cases of practical interest (e.g., Rayleigh and Nakagami-0.5 fading) are also studied. An asymptotic analysis is performed in the high SNR regime, where we observe that IQI results in a ceiling effect on the signal-to-interference-plus-noise ratio (SINR), which depends only on the level of I/Q impairments, i.e., the joint image rejection ratio. Finally, the optimal I/Q amplitude and phase mismatch parameters are provided for maximizing the SINR ceiling, thus improving the system performance. An interesting observation is that, under a fixed total phase mismatch constraint, it is optimal to have the same level of transmitter (TX) and receiver (RX) phase mismatch at the relay node, while the optimal values for the TX and RX amplitude mismatch should be inversely proportional to each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To study the visual acuity and astigmatism of persons undergoing cataract extraction by local surgeons in rural China. METHODS: Visual acuity, keratometry, and refraction were measured 10 to 14 months postoperatively for all cataract cases during 4 months in Sanrao, China. RESULTS: Among 313 eligible subjects, 242 (77%) could be contacted, of whom 176 (73%) were examined. Of those who were examined, mean +/- SD age was 69.3 +/- 10.5 years, 66.5% were female, 35 had been operated on bilaterally at Sanrao, and 85.2% had a preoperative presenting visual acuity of 6/60 or worse. Presenting and best-corrected postoperative acuity in the eye that was operated on were 6/18 or better in 83.4% and 95.7%, respectively. Among 27 fellow eyes operated on elsewhere, 40.7% had a presenting acuity of 6/18 or better and 40.7% were blind (P < .001). Mean +/- SD postoperative astigmatism did not differ between 211 eyes that were operated on (-1.13 +/- 0.84 diopters) and 109 eyes that were not (-1.13 +/- 1.17 diopters; P = .27). Presence of operative complications (8.5%) and older age were associated with worse vision; bilateral surgery was associated with better vision. CONCLUSIONS: These results confirm the effectiveness of skill transfer in this setting, with superior outcomes to most studies in rural Asia and to eyes in this cohort operated on at other facilities.