117 resultados para Hip


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultra-high molecular weight polyethylene (UHMWPE) is used for wear applications in total hip prostheses and total knee prostheses. Sterilisation of these prostheses is commonly by gamma-irradiation. This process creates reactive free radicals in the UHMWPE, greatly increasing its susceptibility to oxidative degradation. This study has investigated the influence of air and vacuum packaging on the properties of gamma-irradiated UHMWPE (GUR1050) following 3 years of shelf ageing. The findings indicate that vacuum packaging minimises oxidative degradation reactions that occur for UHMWPE during shelf ageing. However, gamma-irradiation of vacuum-packaged UHMWPE promotes a degree of cross-linking. It is proposed that this may enhance the wear performance of UHMWPE. Accelerated ageing studies indicate that 3 years of shelf ageing would also seem to reduce the susceptibility of gamma-irradiated UHMWPE to oxidative degradation upon removal from its vacuum packaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During lateral leg raising, a synergistic inclination of the supporting leg and trunk in the opposite direction to the leg movement is performed in order to preserve equilibrium. As first hypothesized by Pagano and Turvey (J Exp Psychol Hum Percept Perform, 1995, 21:1070-1087), the perception of limb orientation could be based on the orientation of the limb's inertia tensor. The purpose of this study was thus to explore whether the final upper body orientation (trunk inclination relative to vertical) depends on changes in the trunk inertia tensor. We imposed a loading condition, with total mass of 4 kg added to the subject's trunk in either a symmetrical or asymmetrical configuration. This changed the orientation of the trunk inertia tensor while keeping the total trunk mass constant. In order to separate any effects of the inertia tensor from the effects of gravitational torque, the experiment was carried out in normo- and microgravity. The results indicated that in normogravity the same final upper body orientation was maintained irrespective of the loading condition. In microgravity, regardless of loading conditions the same (but different from the normogravity) orientation of the upper body was achieved through different joint organizations: two joints (the hip and ankle joints of the supporting leg) in the asymmetrical loading condition, and one (hip) in the symmetrical loading condition. In order to determine whether the different orientations of the inertia tensor were perceived during the movement, the interjoint coordination was quantified by performing a principal components analysis (PCA) on the supporting and moving hips and on the supporting ankle joints. It was expected that different loading conditions would modify the principal component of the PCA. In normogravity, asymmetrical loading decreased the coupling between joints, while in microgravity a strong coupling was preserved whatever the loading condition. It was concluded that the trunk inertia tensor did not play a role during the lateral leg raising task because in spite of the absence of gravitational torque the final upper body orientation and the interjoint coupling were not influenced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Infection remains a severe complication following a total hip replacement. If infection is suspected when revision surgery is being performed, additional gentamicin is often added to the cement on an ad hoc basis in an attempt to reduce the risk of recurrent infection.

Methods and results: In this in vitro study, we determined the effect of incorporating additional gentamicin on the mechanical properties of cement. We also determined the degree of gentamicin release from cement, and also the extent to which biofilms of clinical Staphylococcus spp. isolates form on cement in vitro. When gentamicin was added to unloaded cement (1–4 g), there was a significant reduction in the mechanical performance of the loaded cements compared to unloaded cement. A significant increase in gentamicin release from the cement over 72 h was apparent, with the amount of gentamicin released increasing significantly with each additional 1 g of gentamicin added. When overt infection was modeled, the incorporation of additional gentamicin did result in an initial reduction in bacterial colonization, but this beneficial effect was no longer apparent by 72 h, with the clinical strains forming biofilms on the cements despite the release of high levels of gentamicin.

Interpretation: Our findings indicate that the addition of large amounts of gentamicin to cement is unlikely to eradicate bacteria present as a result of an overt infection of an existing implant, and could result in failure of the prosthetic joint because of a reduction in mechanical performance of the bone cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is known that the method used to mix the liquid monomer and powder of PMMA bone cement influences the quality of the cement that is used in total joint replacements. Mixing theory indicates that the interaction between the liquid monomer and the powder is affected by a number of parameters, such as cement viscosity and degree of agitation, with this knowledge utilized in the design of cement mixing devices. Therefore, the objectives of this study were to: (i) obtain information on the interaction of the liquid monomer and the powder in the case of an PMMA bone cement, (ii) show how this knowledge can be applied to the design of an automated cement mixing device, and (iii) compare the porosity, bending modulus, and bending strength of one commercially-available cement prepared using the automated mixer and prepared using a conventional mixer that is in current clinical use. Experimental data indicated that increasing the velocity and decreasing the viscosity of the systems produced cement that improved mechanical properties, which may contribute to better mechanical integrity and, hence, reduced tendency for aseptic loosening, of cemented hip implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim.  This paper is a presentation of a study protocol to establish the prevalence of orthopaedic problems (hip dislocation, pelvic obliquity, spinal deformity and contractures) and their impact on pain, function, participation and health in a population of children and young people with severe cerebral palsy.

Background.  Cerebral palsy is the commonest cause of motor impairment in childhood and is associated with life-long disability. An estimated 30% of people with cerebral palsy have severe forms and are non-ambulant. Although the underlying neurological damage is not amenable to correction, many health services are dedicated to providing therapeutic and adaptive support to help people with the condition reach their potential.

Method.  A cross-sectional survey of children and young people, aged 4–25 years with severe, non-ambulant cerebral palsy as defined using the Gross Motor Function Classification System (Levels IV and V). Study participants will be identified from a pre-existing, geographically defined case register and recruited via a healthcare professional known to them. Two assessments will be undertaken: one involving parents/carers at home and using questionnaires; the other involving the child/young person ideally in one of three settings and including X-rays if clinically indicated.

Discussion.  This study will contribute to our knowledge of the history and epidemiology of orthopaedic problems in children and young people with cerebral palsy and how these problems accumulate and impact on participation, health and well-being. The study will also identify unmet need and make recommendations for good practice in relation to the orthopaedic care and management for people with severe cerebral palsy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an example of spontaneous transitions between qualitatively different coordination patterns during a cyclic lifting and lowering task. Eleven participants performed 12 trials of repetitive lifting and lowering in a ramp protocol in which the height of the lower shelf was raised or lowered I cm per cycle between 10 and 50 cm. Two distinct patterns of coordination were evident: a squat technique in which moderate range of hip, knee and ankle movement was utilised and ankle plantar-flexion occurred simultaneously with knee and hip extension; and a stoop technique in which the range of knee movement was reduced and knee and hip extension was accompanied by simultaneous ankle dorsi-flexion. Abrupt transitions from stoop to squat techniques were observed during descending trials, and from squat to stoop during ascending trials. Indications of hysteresis was observed in that transitions were more frequently observed during descending trials, and the average shelf height at the transition was 5 cm higher during ascending trials. The transitions may be a consequence of a trade-off between the biomechanical advantages of each technique and the influence of the lift height on this trade-off. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We recently described a sonication technique for the diagnosis of prosthetic knee and hip infections. We compared periprosthetic tissue culture to implant sonication followed by sonicate fluid culture for the diagnosis of prosthetic shoulder infection. One hundred thirty-six patients undergoing arthroplasty revision or resection were studied; 33 had definite prosthetic shoulder infections and 2 had probable prosthetic shoulder infections. Sonicate fluid culture was more sensitive than periprosthetic tissue culture for the detection of definite prosthetic shoulder infection (66.7 and 54.5%, respectively; P = 0.046). The specificities were similar (98.0% and 95.1%, respectively; P = 0.26). Propionibacterium acnes was the commonest species detected among culture-positive definite prosthetic shoulder infection cases by periprosthetic tissue culture (38.9%) and sonicate fluid culture (40.9%). All subjects from whom P. acnes was isolated from sonicate fluid were male. We conclude that sonicate fluid culture is useful for the diagnosis of prosthetic shoulder infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiple osteochondromas is an inherited autosomal dominant condition of enchondral bone growth. The paper undertakes the first synthesis study of the 16 known cases of the condition that have been identified in the international palaeopathological record. It also includes information derived from two newly discovered cases of the disease in two adult male individuals recovered from the Medieval cemetery at Ballyhanna, Co. Donegal, Ireland. The formation of multiple osteochondromas is the best known characteristic of the disease but it also involves the development of a suite of orthopaedic deformities. These deformities, which include disproportionate short stature, inequality of bone length, forearm deformities, tibiofibular diastasis, coxa valga of the hip and valgus deformity of the knee and ankle, are discussed in relation to the archaeological cases. Numerous synonyms for the disease have been used within the various publications produced by palaeopathologists, and this can generate confusion among readers. As such, the paper recommends that in future palaeopathologists should follow the guidance of the World Health Organization and use the term multiple osteochondromas when discussing the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Research has focused on in vitro expansion of bone marrow stromal cells with the aim of developing cell-based therapies or tissue-engineered constructs. There is debate over whether there is a reduction in stem cells/osteoprogenitors in the bone marrow compartment with increasing age. The aim of this study was to investigate patient factors that affect the progenitor pool in bone marrow samples. Six milliliters of marrow aspirate was obtained from the femoral canal of 38 primary hip replacement patients (aged 28-91). Outcome measures were total nucleated cell count, colony-forming efficiency, alkaline phosphatase expression, and expression of stem cell markers. There was a nonsignificant negative correlation between age and both colony-forming efficiency and stem cell marker expression. However, body mass index showed a positive, significant correlation with colony area and number in men-accounting for up to 75% of the variation. In conclusion, body mass index, not age, was highly predictive of the number of progenitors found in bone marrow, and this relationship was sex specific. These results may inform the clinician's treatment choice when considering bone marrow-based therapies. Further, it highlights the need to widen research into patient factors that affect the adult stem cell population beyond age and reinforces the need to consider sexes separately.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The majority of cemented femoral hip replacements fail as a consequence of loosening. One design feature that may affect loosening rates is implant surface finish. To determine whether or not surface finish effects fatigue damage accumulation in a bone cement mantle, we developed an experimental model of the implanted proximal femur that allows visualisation of damage growth in the cement layer. Five matt surface and five polished surface stems were tested. Pre-load damage and damage after two million cycles was measured. Levels of pre-load (shrinkage) damage were the same for both matt and polished stems; furthermore damage for matt vs. polished stems was not significantly different after two million cycles. This was due to the large variability in damage accumulation rates. Finite element analysis showed that the stress is higher for the polished (assumed debonded) stem, and therefore we must conclude that either the magnitude of the stress increase is not enough to appreciably increase the damage accumulation rate or, alternatively, the polished stem does not debond immediately from the cement. Significantly (P = 0.05) more damage was initiated in the lateral cement compared to the medial cement for both kinds of surface finish. It was concluded that, despite the higher cement stresses with debonded stems, polished prostheses do not provoke the damage accumulation failure scenario. (C) 2003 IPEM. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Residual stress due to shrinkage of polymethylmethacrylate bone cement after polymerisation is possibly one factor capable of initiating cracks in the mantle of cemented hip replacements. No relationship between residual stress and observed cracking of cement has yet been demonstrated. To investigate if any relationship exists, a physical model has been developed which allows direct observation of damage in the cement layer on the femoral side of total hip replacement. The model contains medial and lateral cement layers between a bony surface and a metal stem; the tubular nature of the cement mantle is ignored. Five specimens were prepared and examined for cracking using manual tracing of stained cracks, observed by transmission microscopy: cracks were located and measured using image analysis. A mathematical approach for the prediction of residual stress due to shrinkage was developed which uses the thermal history of the material to predict when stress-locking occurs, and estimates subsequent thermal stress. The residual stress distribution of the cement layer in the physical model was then calculated using finite element analysis. Results show maximum tensile stresses normal to the observed crack directions, suggesting a link between residual stress and preload cracking. The residual stress predicted depends strongly on the definition of the reference temperature for stress-locking. The highest residual stresses (4-7 MPa) are predicted for shrinkage from maximum temperature, in this case, magnitudes are sufficiently high to initiate cracks when the influence of stress raisers such as pores or interdigitation at the bone/cement interface are taken into account (up to 24 MPa when calculating stress around a pore according to the method of Harrigan and Harris (J. Biomech. 24(11) (1991) 1047-1058)). We conclude that the damage accumulation failure scenario begins before weight-bearing due to cracking induced by residual stress around pores or stress raisers. (C) 2002 Elsevier Science Ltd. All rights reserved.