153 resultados para Enzyme assays
Resumo:
Malachite Green (MG), Crystal Violet (CV) and Brilliant Green (BC) are antibacterial, antifungal and antiparasitic agents that have been used for treatment and prevention of diseases in fish. These dyes are metabolized into reduced leuco forms (LMG, LCV, LBG) that can be present in fish muscles for a long period. Due to the carcinogenic properties they are banned for use in fish for human consumption in many countries including the European Union and the United States. HPLC and LC-MS techniques are generally used for the detection of these compounds and their metabolites in fish. This study presents the development of a fast enzyme-linked immunosorbent assay (ELISA) method as an alternative for screening purposes. A first monoclonal cell line producing antibodies to MG was generated using a hybridoma technique. The antibody had good cross-reactivates with related chromatic forms of triphenylmethane dyes such as CV, BC, Methyl Green, Methyl Violet and Victoria Blue R. The monoclonal antibody (mAb) was used to develop a fast (20 min) disequilibrium ELISA screening method for the detection of triphenylmethanes in fish. By introducing an oxidation step with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) during sample extraction the assay was also used to detect the presence of the reduced metabolites of triphenylmethanes. The detection capability of the assay was 1 ng g(-1) for MG, LMG, CV, LCV and BC which was below the minimum required performance limit (MRPL) for the detection method of total MG (sum of MG and LMG) set by the Commission Decision 2004/25/EC (2 ng g(-1)). The mean recoveries for fish samples spiked at 0.5 MRPL and MRPL levels with MG and LMG were between 74.9 and 117.0% and inter- and intra-assay coefficients of variation between 4.7 and 25.7%. The validated method allows the analysis of a batch of 20 samples in two to three hours. Additionally, this procedure is substantially faster than other ELISA methods developed for MG/LMG thus far. The stable and efficient monoclonal cell line obtained is an unlimited source of sensitive and specific antibody to MG and other triphenylmethanes. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan™ and minor groove binder (MGB™) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.
Resumo:
Sudan dyes have been found to be added to chilli and chilli products for illegal colour enhancement purposes. Due to the possible carcinogenic effect, they are not authorized to be used in food in the European Union or the USA. However, over the last few years, many products imported from Asian and African countries have been reported via the Rapid Alert System for Food and Feed in the European Union to be contaminated with these dyes. In order to provide fast screening method for the detection of Sudan I (SI), which is the most widely abused member of Sudan dyes family, a unique (20 min without sample preparation) direct disequilibrium enzyme-linked immunosorbent assay (ELISA) was developed. The assay was based on polyclonal antibodies highly specific to SI. A novel, simple gel permeation chromatography clean-up method was developed to purify extracts from matrices containing high amounts of fat and natural pigments, without the need for a large dilution of the sample. The assay was validated according to the Commission Decision 2002/657/EC criteria. The detection capability was determined to be 15 ng g(-1) in sauces and 50 ng g(-1) in spices. The recoveries found ranged from 81% to 116% and inter- and intra-assay coefficients of variation from 6% to 20%. The assay was used to screen a range of products (85 samples) collected from different retail sources within and outside the European Union. Three samples were found to contain high amounts (1,649, 722 and 1,461 ng g(-1)) of SI by ELISA. These results were confirmed by liquid chromatography-tandem mass spectrometry method. The innovative procedure allows for the fast, sensitive and high throughput screening of different foodstuffs for the presence of the illegal colorant SI.
Resumo:
BACKGROUND: We appraised 23 biomarkers previously associated with urothelial cancer in a case-control study. Our aim was to determine whether single biomarkers and/or multivariate algorithms significantly improved on the predictive power of an algorithm based on demographics for prediction of urothelial cancer in patients presenting with hematuria. METHODS: Twenty-two biomarkers in urine and carcinoembryonic antigen (CEA) in serum were evaluated using enzyme-linked immunosorbent assays (ELISAs) and biochip array technology in 2 patient cohorts: 80 patients with urothelial cancer, and 77 controls with confounding pathologies. We used Forward Wald binary logistic regression analyses to create algorithms based on demographic variables designated prior predicted probability (PPP) and multivariate algorithms, which included PPP as a single variable. Areas under the curve (AUC) were determined after receiver-operator characteristic (ROC) analysis for single biomarkers and algorithms. RESULTS: After univariate analysis, 9 biomarkers were differentially expressed (t test; P
Resumo:
Phosphonates constitute a class of natural products that mimic the properties of the more common organophosphate ester metabolite yet are not readily degraded owing to the direct linkage of the phosphorus atom to the carbon atom. Phosphonate hydrolases have evolved to allow bacteria to utilize environmental phosphonates as a source of carbon and phosphorus. The work reported in this paper examines one such enzyme, phosphonoacetate hydrolase. By using a bioinformatic approach, we circumscribed the biological range of phosphonoacetate hydrolase to a select group of bacterial species from different classes of Proteobacteria. In addition, using gene context, we identified a novel 2-aminoethylphosphonate degradation pathway in which phosphonoacetate hydrolase is a participant. The X-ray structure of phosphonoformate-bound phosphonoacetate hydrolase was determined to reveal that this enzyme is most closely related to nucleotide pyrophosphatase/diesterase, a promiscuous two-zinc ion metalloenzyme of the alkaline phosphatase enzyme superfamily. The X-ray structure and metal ion specificity tests showed that phosphonoacetate hydrolase is also a two-zinc ion metalloenzyme. By using site-directed mutagenesis and P-32-labeling strategies, the catalytic nucleophile was shown to be Thr64. A structure-guided, site-directed mutation-based inquiry of the catalytic contributions of active site residues identified Lys126 and Lys128 as the most likely candidates for stabilization of the aci-carboxylate dianion leaving group. A catalytic mechanism is proposed which combines Lys12/Lys128 leaving group stabilization with zinc ion activation of the Thr64 nucleophile and the substrate phosphoryl group.
Resumo:
A sheep trial was performed to evaluate two diagnostic assays, a faecal egg count reduction test (FECRT) and a coproantigen reduction test (CRT), for the diagnosis of resistance of Fasciola hepatica to triclabendazole (TCBZ). The FECRT defines successful TCBZ treatment as a 95% or greater reduction in fluke faecal egg counts (FECs) at 14 days post-treatment (dpt). The CRT defines effective TCBZ treatment as faeces negative for Fasciola coproantigens at 14 dpt, as measured by the commercial BIO K201 coproantigen ELISA (Bio-X Diagnostics, Jemelle, Belgium).
Resumo:
Inflammation is thought to play an important role in the development of cognitive decline and dementia in old age. The interleukin-1 signalling pathway may play a prominent role in this process. The gene encoding for interleukin-1 beta-converting enzyme (ICE) is likely to influence IL-1 beta levels. Inhibition of ICE decreases the age-related increase in IL-1 beta levels and may therefore improve memory function. We assessed whether genetic variation in the ICE gene associates with cognitive function in an elderly population. All 5804 participants of the PROspective Study of Pravastatin in the Elderly at Risk (PROSPER) were genotyped for the 10643GC, 9323GA, 8996AG and 5352GA polymorphisms in the ICE gene. Cross-sectional associations between the polymorphisms and cognitive function were assessed with linear regression. Longitudinal associations between polymorphisms, haplotypes and cognitive function were assessed with linear mixed models. All associations were adjusted for sex, age, education, country, treatment with pravastatin and version of test where appropriate. Subjects carrying the variants 10643C and 5352A allele had significantly lower IL-1 beta production levels (P
Resumo:
Semicarbazide (SEM), the marker residue for the banned nitrofuran veterinary antibiotic nitrofurazone (NFZ), has been detected regularly in foods (47% of recent nitrofuran EU Rapid Alerts involve SEM). However, the validity of SEM as a definitive marker for NFZ has been undermined by SEM arising from other sources including azodicarbonamide, a plastics blowing agent and flour treatment additive. An inexpensive screening test for SEM in food matrices is needed-all SEM testing currently uses expensive LC-MS/MS instrumentation. We now report the first production of antibodies against derivatised SEM. A novel carboxyphenyl SEM derivative was used to raise a polyclonal antibody that has been incorporated into a semi-quantitative microtitre plate ELISA, validated according to the criteria set out in Commission Decision 2002/657/EC, for use with chicken muscle. The antibody is highly specific for derivatised SEM, cross-reactivity being 1.7% with NFZ and negligible with a wide range of other nitrofurans and poultry drugs. Samples are derivatised with o-nitrobenzaldehyde and simultaneously protease digested before extraction by cation exchange SPE. The ELISA has a SEM detection capability (CC beta) of 0.25 mu g kg(-1) when a threshold of 0.21 mu g kg(-1) is applied to the selection of samples for confirmation (lowest observed 0.25 mu g kg(-1) fortified sample, n = 20), thus satisfying the EU nitrofurans' minimum required performance limit of 1 mu g kg(-1). N-FZ-incurred muscles (12) containing SEM at 0.5-5.0 mu g kg(-1) by LC-MS/MS, all screened positive by this ELISA protocol which is also applicable to egg and chicken liver. (C) 2007 Elsevier BN. All rights reserved.
Resumo:
Furazolidone, a nitrofuran antibiotic, is banned from use in food animal production within the European Union. Increasingly, compliance with this ban is monitored by use of analytical methods to detect a stable tissue-bound metabolite, 3-amino-2-oxazolidinone (AOZ). Widespread use of furazolidone in poultry and prawns imported into Europe highlighted the urgent need for development of nitrofuran immunoassay screening tests. The first enzyme-linked immunoabsorbant assay for detection of AOZ residues in prawns (shrimps) is now described. Prawn samples were derivatized with o-nitrobenzaldehyde, extracted into ethyl acetate, washed with hexane and applied to a competitive enzyme immunoassay based on a rabbit polyclonal antiserum. Assay limit of detection (LOD) (mean+3 s) calculated from the analysis of 20 known negative cold and warm water prawn samples was 0.1 mug kg(-1). Intra- and interassay relative standard deviations were determined as 18.8 and 38.2%, respectively, using a negative prawn fortified at 0.7 mug kg(-1). The detection capability (CCbeta), defined as the concentration of AOZ at which 20 different fortified samples yielded results above the LOD, was achieved at fortification between 0.4 and 0.7 mug kg(-1). Incurred prawn samples (n=8) confirmed by liquid chromatography coupled with tandem mass spectrometry detection to contain AOZ concentrations between 0.4 and 12.7 mug kg(-1) were all screened positive by this enzyme-linked immunoabsorbant assay. Further data are presented and discussed with regard to calculating assay LOD based on accepting a 5% false-positive rate with representative negative prawn samples. Such an acceptance improves the sensitivity of an ELISA and in this case permitted an LOD of 0.05 mug kg(-1) and a CCbeta of below 0.4 mug kg(-1).
Resumo:
Zeranol, an oestrogenic growth promoter in food animals, is banned within the European Union (EU). However, commercially available immunoassay kits for zeranol cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the validation of a specificity enhanced, rapid dry reagent time-resolved fluoroimmunoassay (TR-FIA) for zeranol (recovery 99%, limit of detection 1.3 ng ml(-1)) demonstrating that up to 150 ng ml(-1) of Fusarium spp. toxins in urine do not lead to false-positive results. This assay will assist EU Member States to implement Council Directive 961 23\EC, which requires states to monitor for potential abuses of zeranol. A similar TR-FIA for the Fusarium spp. toxin a-zearalenol, using the same sample extract, is also described (recovery 68%, limit of detection 5.6 ng ml(-1)). Only the addition of diluted sample extract is required to perform these dry-reagent TR-FIAs, the results being available within 1 h of extract application. The EU-funded project 'Natural Zeranol' (FAIR5-CT97-3443) will use these fluoroimmunoassays to screen bovine urine in four Member States to gather data on the seasonality of Fusarium spp. toxin contamination of urine and the incidence of zeranol screening test positives.
Resumo:
The means to detect the irradiation of food has been investigated for many years. In recent times radiolytic products, termed 2-alkylcyclobutanones (2-CBs), have been identified as excellent markers of irradiation in lipid-containing foods. An ELISA test was developed, which was capable of detecting a number of these compounds in irradiated chicken meat. A polyclonal antiserum was raised to a 2-CB containing a terminal carboxyl group conjugated to a carrier protein. This antiserum was highly specific for cyclobutanones containing C-10 and C-12 side chains. During assay validation the limit of detection of the assay was calculated to be 0.064 pg of 2-CB per gram of fat, within- and between-assay variations ranged from 6.7 to 18%. During experimental studies, chicken meat irradiated at doses ranging from 2.5 to 10 kGy were assayed and correctly identified as being treated. Quantitative comparisons between the ELISA and CC-MS revealed a good correlation (r(2) = 0.913) between the two methodologies in concentrations of 2-CB detected in irradiated samples.