113 resultados para E51 - Money Supply


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In today’s world, supply chains are becoming more complex and more vulnerable due to increased interdependency of multiple threats. This paper investigates the vulnerability sources in context of sustainable supply chain in order to minimize the impact of uncertain events. The capability-based perspective is discussed in this paper to understand the strategies to improve the resilience of the supply chain. Paper argues that organisations must think beyond their boundaries to accumulate or integrate network resources and develop critical collaborative capabilities across the supply chain to successfully encounter future disruptions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

12. Vlajic, J., Bjelic. N., Vidovic, M., (2006), “Object oriented supply chain simulation in Flexsim”, Proceedings of The microCAD 2006 International Scientific Conference, Miskolc, Hungary, pp.197-203;

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous investigators have not described some of the new anatomic variations or provided quantitative and analytical data of the arterial anatomy of the lips in as much depth as in this study. Dissections of 14 different facial sides of cadavers were done. Through investigating the arterial supply of the upper and lower lips, measurements were performed and statistically analyzed. The main arterial supply of the upper lip was from the superior labial artery (SLA, mean external diameter, 1.8 mm [SD, 0.74 mm]); in addition, the subalar and septal branches contributed to its vascularization. The origin of the SLA was above the labial commissure in 78.6%. The subalar branch was not found but replaced by the alar artery that arose from the infraorbital artery in 1 specimen. The main arterial supply of the lower lip was derived from 3 branches of the facial artery, the inferior labial artery (mean external diameters, 1.4 mm [SD, 0.31 mm]) and the horizontal and vertical labiomental arteries. The inferior labial artery originated mostly below the labial commissure in 42.9% and formed a common trunk with the SLA in 28.6%. The horizontal labiomental artery was present in all, but vertical labiomental artery was absent in 21.4% of specimens. Overall, observed anatomic variations were classified into types I to VIII. Significant relations between the demographic variables and measured parameters were reported including the correlation coefficient among evaluated parameters. In conclusion, this study provides various information that aids in creating new flaps and supports the vascular base for clinical procedures in reconstructive surgery of the lip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A precise knowledge of the sources of the arterial and neural supply of the sternohyoid (SH), sternothyroid (STM), and superior belly of omohyoid (OM) is of value to surgeons using the infrahyoid muscles in reconstruction procedures of the head and neck. This study was designed to define the anatomical bases of the variable sources of the arterial and neural supply of these muscles. Fourteen cadavers were unilaterally dissected in the neck region, and the arterial pedicles of these muscles were followed and accurate measurements were taken. For the SH, two arterial pedicles (superior and inferior) originated from the superior thyroid artery ST and supplied the muscle in 57.1% of cases. The inferior pedicle was absent in 42.9% of cases. As regards the STM, one arterial pedicle from the ST supplied its upper end by multiple branches in 57.1% of cases. In 14.3% of cases, branches from the inferior thyroid artery (IT) supplied the STM in addition to its supply from the ST. As regards the OM, two arterial pedicles originated from the ST and supplied its upper and lower ends in 57.1% of cases. The main artery from the ST to the superior belly of OM entered at its superior portion. The ansa cervicalis (AC) innervated the infrahyoid muscles. SH usually had a double nerve supply. In 57.1% of cases, its superior part was innervated by the nerve to the superior belly of OM. Its inferior part received branches from the AC. In 35.7% of cases, its superior part received direct branches from the AC. As regards the STM, in (71.4%) of cases, a common trunk arose from the loop and supplied the inferior part of both the SH and STM. The nerve supply to the superior belly of OM originated from the AC below the loop in 64.3% of cases. These data will be useful for preserving the neuro-vascular supply of the infrahyoid muscles during flap preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The abductor hallucis flap is commonly used as a pedicled flap (distally or proximally based) in the management of ankle, heel, and mid-foot lesions, where it is ideally used for closing defects. This study investigates the anatomical details of this muscle regarding its various forms of insertion and its arterial supply in 15 cadaveric feet. Four types of insertion could be distinguished: type A, insertion at the proximal phalanx of the big toe (46.7%); type B, insertion by two slips into the base of the proximal phalanx and the sesamoid bone (33.3%); type C, insertion at the sesamoid bone (6.7%); And type D, the insertion is divided into superficial tendinous and deep fleshy parts which are attached to the base of the proximal phalanx and to the metatarsophalangeal joint capsule of the big toe, respectively (13.3%). As regards the arterial supply, three patterns were noticed: pattern A (40%) where the medial plantar artery (MPA) is divided into superficial and deep branches that supplied the muscle; pattern B (53.3%) where the MPA failed to produce a deep branch but instead continued as the superficial branch supplying the two ends of the muscle; and pattern C (6.6%) where the MPA continued as a deep branch supplying the muscle. A superficial branch of MPA provided a branch to the abductor hallucis muscle from its proximal part. In two specimens (13.3%), the lateral plantar artery shared in the supply of the most proximal part of the muscle. These results can be useful in determining the appropriate flap design based on the abductor hallucis type of insertion and the pattern of its arterial supply in the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to analyse vulnerability and robustness of small and medium size enterprises (SMEs) supply chains and to consider contextual factors that might influence the success of their disturbance management: Risky product and business environment. By using an exploratory case study it is shown how these contextual factors attribute vulnerability sources, contribute to the robustness of a company’s performance and supply chain vulnerability, as well as how a company seeks to manage internal and external vulnerability sources. The exploratory case is based on a fresh food supply chain of a manufacturing SME operating in a developing market.
Case findings suggest that fresh food supply chains of a manufacturing SME in developing markets are prone to disruptions of their logistics and production processes due to ‘riskiness’ of fresh food products, the ‘riskiness’ of developing markets, as well as ‘riskiness’ of SMEs themselves. However, this does not necessarily indicate the vulnerability of an SME and its entire supply chain. Findings indicate that SMEs can be very successful in disturbance management by selective use of redesign strategies that aim to prevent or reduce the impact of disturbances. More precise, it is likely that an SME can achieve robust performance by employing preventive redesign strategies in managing disturbances that result from internal, company related vulnerability sources, while impact reduction strategies are likely to contribute to robust performance of an SME if used to manage disturbances that result from internal, supply chain related vulnerability sources, as well as external vulnerability sources.